COOLING SYSTEM
7-14
RADIATOR RESERVE TANK
REMOVAL/INSTALLATION
Remove the following:
– floor side cover (page 3-8)
– front inner cover (page 3-10)
– floor panel (page 3-13)
Drain the coolant from the system (page 7-7).
Disconnect the over flow hose and siphon hose
from the reserve tank.
Remove the mounting bolts and reserve tank.
Installation is in the reverse order of removal.
Fill the reserve tank to the upper level line, if it was
drained (page 4-14).
RADIATOR
RESERVE TANK
SIPHON HOSE
OVER FLOW HOSE
BOLTS