18-17
• STARTER SOLENOID
Use a known-good battery and connect it to the starter
solenoid terminals with care not to short-circuit the starter
solenoid.
1) Connect the battery cables to the starter solenoid terminals
as shown, and check for continuity between the terminals.
NOTICE
b. INSPECTION
• MAIN RELAY
Use a known-good battery and connect it to the main relay
terminals with care not to short-circuit the main relay.
1) Connect the battery cables to the main relay terminals as
shown, and check for continuity between the terminals.
NOTICE
• NEUTRAL SWITCH
1) Check for continuity between the terminals with the switch
in each position.
3) If there is any abnormality, replace the main relay.
2) Disconnect the battery cables from the main relay
terminals, and check for continuity between the terminals.
Between No.3 and No.4 terminals
No continuity
[4]
(+) to
No.8
terminal
[6]
(-) to
No.7
terminal
Between No.3 and No.4 terminals
Continuity
3) If there is any abnormality, replace the starter solenoid.
2) Disconnect the battery cables from the terminals, and
check for continuity between the terminals.
[4]
(+) to
Black/White
terminal
[6]
(-) to
Black/Blue
terminal
[2]
M TERMINAL
[1]
B TERMINAL
Bl/G
Bl
[2] ON
[3] OFF
: [4] Continuity
2) If there is any abnormality, replace the neutral switch.
[3]
OFF
[2]
ON
[1]
NEUTRAL SWITCH
[1]
MAIN RELAY
[3]
STARTER
SOLENOID
Bl/G
Bl
[5]
12V BATTERY
[2]
No.3
[3]
No.4
Between B and M terminals
Continuity
Between B and M terminals
No continuity
[5]
12V BATTERY
692