20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
16-36
• INDICATOR LIGHT
• Use a known-good battery to check the indicator light.
1) Route the indicator light wires as shown. Connect the
switch 1 and the switch 2, which are connected to the
battery negative (-) cable, to the Black and Yellow
terminals.
Connect the battery positive (+) cable to the Black/Yellow
terminal and apply battery voltage (12V) to the terminal.
Check that the light 1 (Green light) comes ON when the
switch 1 is ON.
Check that the light 1 (Green light) goes OFF when the
switch 1 and the switch 2 are ON.
[3]
INDICATOR
LIGHT
[4] LIGHT 1
Y
Bl
Bl/Y
12V
[2]
SWITCH 1
[1]
SWITCH 2
2) Connect the battery positive (+) cable to the indicator light
Black/Yellow terminal and the battery negative (-) cable to
the White/Blue terminal as shown. The light 2 (Red light)
should come ON.
3) Connect the battery positive (+) cable to the indicator light
Black/Yellow terminal and the battery negative (-) cable to
the Red terminal as shown. The light 3 (Red light) should
come ON.
4) Connect the battery positive (+) cable to the indicator light
Black/Yellow terminal and the battery negative (-) cable to
the Red/Blue terminal as shown. The light 4 (Red light)
should come ON.
5) If there is any abnormality, replace the indicator light with
a new one.
[4]
INDICATOR
LIGHT
R/Bu
[1] LIGHT 1
[5] LIGHT 3
[2] LIGHT 2
[3] LIGHT 4
R
W/Bu
Bl/Y
12V
630