39
OPERATION
AC OPERATION
Connect a RCBO (Residual current circuit breaker with overload
protection) of 30 mA ground fault detection and cut-off of less than
0.4 seconds at more than 30 A of output current, if you are using two
or more appliance.
Follow the instructions provided by each RCBO manufacturer before
use.
If an appliance begins to operate abnormally, becomes sluggish, or
stops suddenly, turn it off immediately. Disconnect the appliance, and
determine whether the problem is in the appliance or the rated load
capacity of the generator has been exceeded.
Substantial overloading that continuously lights the red OVERLOAD
ALARM indicator may damage the generator. Marginal overloading that
temporarily lights the red OVERLOAD ALARM indicator may shorten
the service life of the generator.
1.Start the engine and make
sure the green OUTPUT
indicator comes on.
GENERATOR
APPLIANCES
RCBO
GENERATOR
RCBO
RCBO
APPLIANCES
Connecting with one RCBO
Connecting with two RCBO
OUTPUT INDICATOR (GREEN)
36Z376000.book 39 ページ 2014年9月19日 金曜日 午後6時26分