Connect a RCBO (Residual current circuit breaker with overload protection) of
30 mA ground fault detection and cut-off of less than 0.4 seconds at more than
30 A of output current, if you are using two or more appliance.
Follow the instructions provided by each RCBO manufacturer before use.
1. Start the engine (see page 40) and make sure the output indicator (green)
comes ON.
2. Plug in the appliance.
GENERATOR
RCBO
APPLIANCES
Connecting with one RCBO
GENERATOR
RCBO
APPLIANCES
RCBO
Connecting with two RCBO
OVERLOAD ALARM INDICATOR
(RED)
OUTPUT INDICATOR
(GREEN)
AC RECEPTACLE
F, G Types
AC RECEPTACLE
IT Type