background image

STORAGE

65

STORAGE PRECAUTIONS

If your generator will be stored with gasoline in the fuel tank, it is important to 
reduce the hazard of gasoline vapor ignition.

Select a well-ventilated storage area away from any appliance that operates 
with a flame, such as a furnace, water heater, or clothes dryer.
Also, avoid any area with a spark-producing electric motor, or where power 
tools are operated.

If possible, avoid storage areas with high humidity, because that promotes rust 
and corrosion.

Place the generator on a level surface. Tilting or laying it on its side can cause 
fuel or oil leakage.

With the engine and exhaust system cool, cover the generator to keep out dust. 
A hot engine and exhaust system can ignite or melt some materials.

Do not use a plastic sheet as a dust cover. A nonporous cover will trap moisture 
around the generator, promoting rust and corrosion.

REMOVAL FROM STORAGE

Check your generator as described in the "BEFORE OPERATION" chapter of this 
manual (see page 32).

If the fuel was drained during storage preparation, fill the fuel tank with fresh 
gasoline. If you keep a container of gasoline for refueling, be sure that it 
contains only fresh gasoline. Gasoline oxidizes and deteriorates over time, 
causing hard starting.

If the cylinder was coated with oil during storage preparation, the engine may 
smoke briefly at startup. This is normal.

Summary of Contents for EU3200i

Page 1: ...n EU3200i 31Z45600 00X31 Z45 6000 GENERATOR Owner s Manual H i FM AH 英 PANTONE 186C K 背幅4 6mm EU3200i See page 13 for Initial Use Instructions 2022 Honda Motor Co Ltd All Rights Reserved C 00X31Z45 6000 00X31Z45 6000 ...

Page 2: ...inue or change specifications or design at any time without notice and without incurring any obligation whatsoever The illustration may vary according to the type Theengineexhaustfromthisproduct contains chemicalsknownto the Stateof Californiato cause cancer birth defects or other reproductiveharm Exhaust contains poisonous carbon monoxide gas that can build up to dangerous levels in enclosed or p...

Page 3: ... the Distributor s Limited Warranty see page 79 to fully understand its coverage and your responsibilities of ownership When your generator needs scheduled maintenance keep in mind that your Honda servicing dealer is specially trained in servicing Honda generators and is supported by the parts and service divisions of American Honda Your Honda servicing dealer is dedicated to your satisfaction and...

Page 4: ... the generator Instructions how to use this generator correctly and safely Safety Headings such as IMPORTANT SAFETY INFORMATION Safety Messages preceded by a safety alert symbol and one of three signal words DANGER WARNING or CAUTION These signal words mean This entire book is filled with important safety information please read it carefully DAMAGE PREVENTION MESSAGES In addition to the above you ...

Page 5: ...LS FEATURES 18 COMPONENT CONTROL LOCATIONS 18 CONTROLS 20 Engine Switch 20 Starter Grip 20 Eco Throttle Switch 21 CO MINDER CO Shut off System 22 Parallel Operation Outlets 24 AC Circuit Protector 24 FEATURES 25 Ground Terminal 25 Fuel Level Indicator 25 Output Indicator 26 Overload Alarm Indicator 27 Oil Alert Check Indicator 27 LED Light Patterns 28 Bluetooth Function 29 Smartphone application 2...

Page 6: ...on Applications 46 ECO THROTTLE SYSTEM 49 STANDBY POWER 50 Connections to a Building s Electrical System 50 System Ground 50 Special Requirements 51 SERVICING YOUR GENERATOR 52 THE IMPORTANCE OF MAINTENANCE 52 MAINTENANCE SAFETY 53 Safety Precautions 53 MAINTENANCE SCHEDULE 54 ENGINE OIL CHANGE 55 AIR CLEANER SERVICE 56 Foam Air Filter Cleaning 56 SPARK PLUG SERVICE 57 SPARK ARRESTER SERVICE 59 ST...

Page 7: ...R FLASHING WHEN RUNNING THE ENGINE 69 TECHNICAL INFORMATION 70 SERIAL NUMBER LOCATION 70 EMISSION CONTROL SYSTEM INFORMATION 71 Air Index 73 SPECIFICATIONS 74 WIRING DIAGRAM 76 CONSUMER INFORMATION 77 DEALER LOCATOR INFORMATION 77 Honda PUBLICATIONS 77 CUSTOMER SERVICE INFORMATION 78 Distributor s Limited Warranty 79 Emission Control System Warranty 84 REGISTRATION 89 Please Register Your Generato...

Page 8: ...n hazards are discussed below along with the best way to protect yourself and others Operator Responsibility Never attempt to modify the generator It can cause an accident as well as damage to the generator and appliances Know how to stop the generator quickly in case of emergency Understand the use of all generator controls output receptacles and connections Be sure that anyone who operates the g...

Page 9: ... monoxide exposure include headache fatigue shortness of breath nausea and dizziness Continued exposure to carbon monoxide can cause loss of muscular coordination loss of consciousness and then death To alert you to potentially dangerous levels of carbon monoxide coming from a generator operating outside or from other sources install battery operated carbon monoxide alarms or plug in carbon monoxi...

Page 10: ...tdoors unprotected from the weather check all of the electrical components on the control panel before each use Moisture or ice can cause a malfunction or short circuit in electrical components that could result in electrocution Do not connect to a building s electrical system unless an isolation switch has been installed by a qualified electrician For parallel operation use only a Honda approved ...

Page 11: ...le after stopping the engine Be careful not to touch the muffler while it is hot Let the engine cool before storing the generator Do not pour the water directly on the generator to put out the fire when it occurs Use an appropriate fire extinguisher specially designed for electric fire or oil fire Refuel With Care Gasoline is highly flammable and gasoline vapor can explode Do not refuel during ope...

Page 12: ...ng transported or while it is mounted to any type vehicle trailer or boat Do not operate the generator when it is in a storage cargo or security enclosure including any RV generator bay Always completely remove the generator from the vehicle RV truck trailer boat other equipment or structure during operation The generator must remain stationary while in operation ...

Page 13: ...ETY 11 SAFETY LABEL LOCATIONS These labels warn you of potential hazards that can cause serious injury Read them carefully If a label comes off or becomes hard to read contact your servicing dealer for a replacement ...

Page 14: ...GENERATOR SAFETY 12 ...

Page 15: ...filler neck SAE10W 30 API service category SJ or later or equivalent is recommended for general use for additional recommendations see page 14 Maximum oil capacity 15 oz 0 46 L Do not overfill the engine with oil If the engine is overfilled the excess oil may be transferred to the air cleaner housing and air filter 5 Screw in the oil filler cap securely 6 Reinstall the maintenance cover and tighte...

Page 16: ...for general use Other viscosities shown in the chart may be used when the average temperature in your area is within the recommended range Read the instructions on the oil container before use The SAE oil viscosity and API service category are in the API label on the oil container Honda recommends that you use API service category SJ or later or equivalent oil AMBIENT TEMPERATURE ...

Page 17: ...pped check the fuel level indicator for the fuel level If the fuel level is low wait for the generator to cool off and refill the fuel tank This engine is certified to operate on unleaded gasoline with a pump octane rating 86 or higher Refer to FUEL RECOMMENDATIONS see page 17 for additional fuel recommendations Fuel can damage paint and plastic Be careful not to spill fuel when filling your fuel ...

Page 18: ...areful not to spill fuel when filling your fuel tank Damage caused by spilled fuel is not covered under the Distributor s Limited Warranty U S Distributor s Warranty C A 3 After refueling tighten the fuel filler cap until it clicks Move the generator at least 10 feet 3 meters away from the fueling source and site before starting the engine FUEL FILLER CAP UPPER LEVEL MARK RED TETHER FUEL STRAINER ...

Page 19: ...olume In addition methanol must contain cosolvents and corrosion inhibitors Use of fuels with content of ethanol or methanol greater than shown above may cause starting and or performance problems It may also damage metal rubber and plastic parts of the fuel system Engine damage or performance problems that result from using a fuel with percentages of ethanol or methanol greater than shown above a...

Page 20: ...CATIONS Use the illustrations on these pages to locate and identify the most frequently used controls SPARK PLUG MAINTENANCE COVER MUFFLER SPARK PLUG FRAME SERIAL NUMBER AIR CLEANER FUEL FILLER CAP STARTER GRIP MAINTENANCE COVER UNDERGRIP GRIP ...

Page 21: ...le you must have another EU3200i generator connected in parallel see page 45 The combined output of both outlets in the receptacle is 20 A ECO THROTTLE SWITCH GROUND TERMINAL PARALLEL OPERATION OUTLETS 20 A receptacle AC CIRCUIT PROTECTORS INDICATORS CO MINDER 30 A twist lock receptacle ENGINE SWITCH ...

Page 22: ...e engine ON Running position and for starting with the recoil starter Starter Grip Pulling the starter grip operates the recoil starter to start the engine Do not allow the starter grip to snap back against the generator Return it gently to prevent damage to the starter ENGINE SWITCH ON OFF STARTER GRIP ...

Page 23: ... voltage changes OVERLOAD RESET If the power generation stops due to overload and the overload alarm indicator is blinking overload reset is available After removing the cause of the overload power generation can be resumed by pressing and holding the Eco Throttle switch for more than 3 seconds Eco Throttle system ON Indicator lights on green Recommended to minimize fuel consumption and further re...

Page 24: ... monoxide Ventilate the area or space where the generator is located If the engine is stopped by the CO MINDER system change the operating location of the generator Do not operate the generator in an enclosed or partly enclosed area such as a garage Do not enclose or cover the generator with boards or a tent even when it is outside and away from of a building Place the generator so that the muffle...

Page 25: ...may be a system malfunction If this occurs do not attempt to restart the generator more than two times If the CO MINDER system is malfunctioning it cannot warn you of potential high concentrations of carbon monoxide Move the generator to a well ventilated location and consult an authorized Honda Power Equipment dealer CO SENSOR LIFE If the FAULT CO SENSOR LIFE indicator flashes when operating the ...

Page 26: ... AC Circuit Protector The AC circuit protectors will automatically switch OFF if there is a short circuit or a significant overload of the generator at each receptacle If an AC circuit protector switches OFF automatically check that the appliance is working properly and does not exceed the rated load capacity of the circuit before resetting the AC circuit protector ON PARALLEL OPERATION OUTLETS 20...

Page 27: ...or stator winding is isolated from the frame and from the AC receptacle ground pin Electrical devices that require a grounded receptacle pin connection will not function if the receptacle ground pin is not functional Fuel Level Indicator The fuel level indicator is a mechanical device that measures the fuel level in the tank To provide increased operating time start with a full tank before operati...

Page 28: ...cal power at the receptacles In addition the output indicator has a simplified hour meter function When you start the engine the indicator blinks according to the generator s cumulative operating hours as follows No blinks 0 100 hours 1 blink 100 200 hours 2 blinks 200 300 hours 3 blinks 300 400 hours 4 blinks 400 500 hours 5 blinks 500 or more hours OUTPUT INDICATOR GREEN ...

Page 29: ...engine damage caused by an insufficient amount of oil in the crankcase Before the oil level in the crankcase can fall below a safe limit or in the case of engine overheat the Oil Alert Check indicator red comes ON and the Oil Alert system automatically will stop the engine the engine switch will remain in the ON position If the engine stops or the Oil Alert Check indicator red comes ON when you pu...

Page 30: ...sis Status Possible cause Output Indicator Oil Alert Check Indicator Overload Alarm Indicator Normal Operating normally Malfunction Inverter unit failure etc Abnormal Output overcurrent Inverter unit overheat Warning Engine oil low Tilt detection Engine overheat OIL ALERT CHECK INDICATOR OVERLOAD ALARM INDICATOR OUTPUT INDICATOR ...

Page 31: ...tors equipped with Bluetooth technology The application is able to do the following convenient functions Remote stop Can stop the generator engine from a distance Remote change the Eco Throttle system from a distance Remote monitoring Displays power output level and remaining fuel level etc Receive notifications Can receive error and maintenance alerts Downloading the app Go to the App Store iOS o...

Page 32: ...OLS FEATURES 30 The indicator according to the Bluetooth connection as follows OFF Not connected Fast Blinking Malfunction Slow Blinking Pairing available ON Connected BLUETOOTH INDICATOR BLUETOOTH PASSWORD ...

Page 33: ...ROLS FEATURES 31 Grip and Undergrip Use the hand grip when lifting the generator In addition to using the grip you can lift the generator using the undergrip with your other hand if necessary GRIP UNDERGRIP ...

Page 34: ...the generator s load rating see pages 44 and 48 IS YOUR GENERATOR READY TO GO For your safety to ensure compliance with environmental regulations and to maximize the service life of your equipment it is very important to take a few moments before you operate the generator to check its condition Be sure to take care of any problem you find or have your servicing dealer correct it before you operate...

Page 35: ...see page 35 Dirty air filters will restrict air flow to the fuel system reducing engine and generator performance Check the fuel level see page 15 Starting with a full tank will help to eliminate or reduce operating interruptions for refueling AC Appliance and Power Cord Before connecting an AC appliance or power cord to the generator Use grounded 3 prong extension cords tools and appliances or do...

Page 36: ...oil level is near or below the lower limit fill with the recommended oil to the upper limit Do not overfill Upper limit means the oil exists to the oil filler neck Lower limit means the oil is attached only to the lower end of the dipstick Refer to ENGINE OIL RECOMMENDATIONS in page 14 5 Reinstall the oil filler cap securely 6 Reinstall the maintenance cover and tighten the maintenance cover screw...

Page 37: ...r cleaner cover 3 Remove the foam air filter from the air cleaner cover 4 Check the foam air filter to be sure it is clean and in good condition If the foam air filter is dirty clean it as described on page 56 Replace the foam air filter if it is damaged 5 Reinstall the foam air filter in the air cleaner cover 6 Remove the paper filter from the guide 7 If the paper air filter is dirty replace it w...

Page 38: ...maintenance cover and tighten the maintenance cover screw securely Operating the engine without the air filters or with a damaged air filter will allow dirt to enter the engine causing rapid engine wear This type of damage is not covered by the Distributor s Limited Warranty U S Distributor s Warranty C A ...

Page 39: ... structures vehicles trailers or boats Do not operate the generator when it is in a storage cargo or security enclosure including any RV generator bay Always completely remove the generator from the vehicle trailer boat or other equipment or structure during operation The generator must remain stationary while in operation Exhaust contains poisonous carbon monoxide gas that can build up to dangero...

Page 40: ... Keep all cooling holes open and clear of debris mud water etc Cooling holes are located on the side panel the control panel and the bottom of the generator If the cooling holes are blocked the generator may overheat and damage the engine inverter or windings Since the CO MINDER may detect the carbon monoxide concentration and the engine may stop automatically pay attention to the direction of exh...

Page 41: ...arrow as shown Do not allow the starter grip to snap back against the generator Return it gently to prevent damage to the starter 4 If you don t wish to use the Eco Throttle system push the Eco Throttle switch to Eco Throttle system OFF STARTER GRIP ECO THROTTLE SWITCH Direction to pull ECO THROTTLE INDICATOR OFF ...

Page 42: ...llowing procedure 1 Turn off or disconnect all appliances that are connected to the generator 2 Turn the engine switch to the OFF position securely 3 If two generators were connected for parallel operation disconnect the parallel cable after stopping the engines if you do not wish to resume parallel operation ENGINE SWITCH OFF PARALLEL CABLE optional equipment ...

Page 43: ... CO MINDER move the generator to an area with fresh air and away from any device that may be emitting carbon monoxide such as another generator Press the CO MINDER reset button and then follow the standard procedure for starting the engine When the CO ALARM indicator or the FAULT CO MINDER LIFE indicator flashes press the CO MINDER reset button to turn off the indicator After the engine is stopped...

Page 44: ...temporarily lights the overload alarm indicator red may shorten the service life of the generator Be sure that all appliances are in good working order before connecting them to the generator Electrical equipment including lines and plug connections should not be defective If an appliance begins to operate abnormally becomes sluggish or stops suddenly turn off the generator engine switch immediate...

Page 45: ... overload alarm indicator red will stay ON and after about 10 seconds when an overload or about 5 seconds in case of a short circuit current to the connected appliance s will shut off and the output indicator green will go OFF Stop the engine and investigate the problem Determine if the cause is a short circuit in a connected appliance or an overload Correct the problem and restart the generator R...

Page 46: ...than their rated wattage for startup Make sure the electrical rating of the tool or appliance does not exceed the maximum power rating of the generator Maximum power is 3 2 kVA For continuous operation do not exceed the rated power Rated power is 2 6 kVA In either case the total power requirements VA of all appliances connected must be considered Appliance and power tool manufacturers usually list...

Page 47: ... may come ON This is normal if the overload alarm indicator red goes OFF within 4 seconds If the Oil Alert Check indicator red blink continuously consult an authorized Honda Power Equipment dealer During parallel operation the Eco Throttle switch should be in the same position on both generators 1 Connect the parallel cable between the two EU3200i generators following the instructions supplied wit...

Page 48: ...restart the generator AC Parallel Operation Applications Follow the instructions included with the parallel cable Before connecting an appliance or power cord to the generator Make sure that it is in good working order A faulty appliance or power cord can create a potential for electrical shock If an appliance begins to operate abnormally becomes sluggish or stops suddenly turn it off immediately ...

Page 49: ... parallel operation Align the two generators so that their mufflers are on the same line and exhaust in the same direction Place the generator so that the muffler is pointed in the same direction as the wind is blowing and the exhaust is directed away from buildings other structures or vehicles EXHAUST EXHAUST ON THE SAME LINE WIND DIRECTION WIND DIRECTION This generator may detect exhaust from th...

Page 50: ...rated power Rated power in parallel operation is 5 2 kVA In either case the total power requirements VA of all appliances connected must be considered Appliance and power tool manufacturers usually list rating information near the model number or serial number Substantial overloading that continuously lights the overload alarm indicator red may damage the generator Marginal overloading that tempor...

Page 51: ...enerator If the engine still will not reach normal operating speed check that the appliance does not exceed the rated load capacity of the generator If high electrical loads are connected simultaneously turn the Eco Throttle system to OFF to reduce voltage changes The Eco Throttle system is not effective for use with appliances or tools that require only momentary power If the tool or appliance wi...

Page 52: ...stration and use procedures System Ground This generator has a system ground that connects the generator frame components to ground terminals in the AC output receptacles The system ground is not connected to the AC neutral wire Improper connections to a building s electrical system can allow current from the generator to backfeed into the utility lines Such backfeed may electrocute utility compan...

Page 53: ...Safety and Health Administration OSHA regulations local codes or ordinances that apply to the intended use of the generator Please consult a qualified electrician electrical inspector or the local agency having jurisdiction In some areas generators are required to be registered with local utility companies If the generator is used at a construction site there may be additional regulations that mus...

Page 54: ...r high temperature operation or use it in dusty conditions consult your servicing dealer for recommendations applicable to your individual needs and use Remember that an authorized Honda Power Equipment dealer knows your generator best and is fully equipped to maintain and repair it To ensure the best quality and reliability use only new Honda Genuine parts or their equivalents for repair and repl...

Page 55: ...ng from engine exhaust Operate outside away from open windows or doors with engine exhaust directed away from occupied structures Burns from hot parts Let the engine and exhaust system cool before touching Injury from moving parts Do not run the engine unless instructed to do so To reduce the possibility of fire or explosion be careful when working around gasoline Use only a non flammable solvent ...

Page 56: ...onth or operating hour interval whichever comes first ITEM Each use First month or 20 Hrs Every 3 months or 50 Hrs Every 6 months or 100 Hrs Every year or 300 Hrs Page Engine oil Check level o 34 Change first time from purchase o 55 Change o 55 Air cleaner element Check o 35 Clean o 1 56 Replace o 35 Spark plug Check adjust o 57 Replace o 57 Spark arrester Clean o 59 Timing belt Check After every ...

Page 57: ...al of engine oil can be harmful to the environment If you change your own oil please dispose of the used oil properly Do not discard it in a trash bin dump it on the ground or pour it down the drain 5 With the generator in a level position fill with the recommended oil to the upper limit Do not overfill Upper limit means the oil exists to the oil filler neck Refer to ENGINE OIL RECOMMENDATIONS in ...

Page 58: ... Clean the foam air filter in warm soapy water rinse and allow to dry thoroughly or clean in nonflammable solvent and allow to dry 2 Dip the foam air filter in clean engine oil and then squeeze out all excess oil The engine will smoke when started if too much oil is left in the filter 3 Wipe dirt from inside of the air cleaner cover using a moist rag Be careful to prevent dirt from entering the ai...

Page 59: ...plug must be properly gapped and free of deposits An incorrect spark plug can cause engine damage If the engine is hot allow it to cool before servicing the spark plug 1 Remove the spark plug maintenance cover 2 Disconnect the spark plug cap and remove any dirt from around the spark plug area 3 Remove the spark plug with a spark plug wrench SPARK PLUG MAINTENANCE COVER SPARK PLUG CAP SPARK PLUG WR...

Page 60: ...on and thread the spark plug in by hand to prevent cross threading 7 After the spark plug is seated tighten with a spark plug wrench to compress the washer If reinstalling a used spark plug tighten 1 8 1 4 turn after the spark plug is seated If installing a new spark plug tighten 1 2 turn after the spark plug is seated Torque 9 lbf ft 12 N m 1 2 kgf m A loose spark plug can overheat and damage the...

Page 61: ...been running the muffler will be very hot Allow the muffler to cool before servicing the spark arrester Clean the spark arrester as follows 1 Remove the two 6 15 mm screws and the rear cover Remove the two 6 mm screws two 6 15 mm screws and the muffler protector MUFFLER PROTECTOR 6 mm SCREWS REAR COVER 6 15 mm SCREWS 6 15 mm SCREWS 6 mm SCREW 6 15 mm SCREW ...

Page 62: ...n deposits from the spark arrester screen Be careful to avoid damaging the screen The spark arrester must be free of breaks and tears Replace the spark arrester if it is damaged 4 Install the spark arrester the muffler protector and the rear cover in the reverse order of removal SPARK ARRESTER 4 mm SCREW ...

Page 63: ...l cause hard starting and it leaves gum deposits that clog the fuel system If the gasoline in your generator deteriorates during storage you may need to have the fuel system components serviced or replaced The length of time that gasoline can be left in your fuel tank without causing functional problems will vary with such factors as gasoline blend your storage temperatures and whether the fuel ta...

Page 64: ...he spark plug Put a teaspoon of engine oil into the cylinder Turn the engine slowly with the pull rope to distribute the oil Reinstall the spark plug Change the engine oil see page 55 After removal from storage drain the stored gasoline into a suitable container and fill with fresh gasoline before starting Use gasoline stabilizers that are formulated to extend storage life Follow the manufacturer ...

Page 65: ...iphon the gasoline by inserting the tip of the hand pump into the side of the pump guard as shown in the figure below Reinstall the fuel strainer and the fuel filler cap Gasoline is highly flammable and explosive You can be burned or seriously injured when handling fuel Stop the engine and let it cool before handling fuel Keep heat sparks and flame away Handle fuel only outdoors Keep away from you...

Page 66: ...rter rope several times to distribute the oil in the cylinder 4 Reinstall the spark plug see page 57 5 Slowly pull the starter grip until resistance is felt At this point the piston is coming up on its compression stroke and both the intake and exhaust valves are closed Storing the engine in this position will help to protect it from internal corrosion Return the starter grip gently ...

Page 67: ...r oil leakage With the engine and exhaust system cool cover the generator to keep out dust A hot engine and exhaust system can ignite or melt some materials Do not use a plastic sheet as a dust cover A nonporous cover will trap moisture around the generator promoting rust and corrosion REMOVAL FROM STORAGE Check your generator as described in the BEFORE OPERATION chapter of this manual see page 32...

Page 68: ... operating it Oil or fuel may leak and damage the engine or your property Do not operate the generator while it is being transported or while it is mounted to any type of vehicle trailer or boat Take care not to drop or strike the generator when transporting Do not place heavy objects on the generator An engine that has been running will remain very hot for a period of time A hot engine and exhaus...

Page 69: ...witch to the ON position and restart the engine Spark plug faulty fouled or improperly gapped Gap or replace spark plug see page 57 Spark plug wet with fuel flooded engine Dry and reinstall spark plug Fuel filter restricted fuel system malfunction fuel pump failure ignition malfunction valves stuck etc Take the generator to an authorized Honda Power Equipment dealer or refer to the shop manual CO ...

Page 70: ...dealer or refer to the shop manual Possible Cause Correction Output indicator is OFF and overload alarm indicator is ON Check AC load Stop and restart the engine Check the cooling air inlet Stop and restart the engine Overload alarm indicator blink After removing the cause of the overload power generation can be resumed by pressing and holding the Eco Throttle switch for more than 3 seconds see pa...

Page 71: ...stopped automatically by CO MINDER press the CO MINDER reset button to restart the engine see page 41 Possible Cause Correction CO sensor malfunction If the engine cannot be started and the CO ALARM indicator flashes even if the location of the generator has changed there may be a CO MINDER malfunction Consult an authorized Honda Power Equipment dealer CO sensor may have reached the end of its use...

Page 72: ...LOCATION Record the frame serial number and date purchased in the spaces below You will need this information when ordering parts and when making technical or warranty inquiries Frame serial number Date purchased FRAME SERIAL NUMBER QR CODE ...

Page 73: ...chnologies to reduce evaporative emissions The U S and California Clean Air Acts and Environment and Climate Change Canada ECCC U S EPA California and Canadian regulations require all manufacturers to furnish written instructions describing the operation and maintenance of emission control systems The following instructions and procedures must be followed in order to keep the emissions from your H...

Page 74: ...e parts certified by the EPA CARB or ECCC as applicable and have service performed at non Honda locations However the use of replacement parts that are not of the original design and quality may impair the effectiveness of your emissions control system A manufacturer of an aftermarket part assumes the responsibility that the part will not adversely affect emissions performance The manufacturer or ...

Page 75: ...less pollution The durability description is intended to provide you with information relating to the engine s emission durability period The descriptive term indicates the useful life period for the engine s emission control system See your Emission Control System Warranty see page 84 for additional information Descriptive Term Applicable to Emission Durability Period Moderate 50 hours 0 80 cc in...

Page 76: ...gle cylinder Displacement Bore Stroke 7 93 cu in 130 cm3 2 20 2 09 in 56 0 53 0 mm Compression ratio 10 0 1 Engine speed 4 800 5 500 rpm with Eco Throttle system OFF Cooling system Forced air Ignition system Full transistor Engine oil capacity 15 oz 0 46 L Fuel tank capacity 1 21 US gal 4 6 L Spark plug CR6HSB NGK Model EU3200i Type AC AN AC output Rated voltage 120 V Rated frequency 60 Hz Rated c...

Page 77: ...s are subject to change without notice ITEM SPECIFICATION MAINTENANCE Spark plug gap 0 024 0 028 in 0 6 0 7 mm Refer to page 57 Valve clearance cold IN 0 15 0 02 mm EX 0 15 0 02 mm See your authorized Honda dealer Other specifications No other adjustments needed ...

Page 78: ... W G W R G Y Y G Y G Y R Bu Bu G Y R Y Bl R R W R G Y G Y Y R R G Y Y Br Bl Bl Bl Bl Bl R Y P Bu G Bl G Y Bu R Y G Y G Y G Y W R R R Lg G Y G Y R Bu Bu W W R Y Bu Bu W R R W Bu W R Bu W R Bu G Y R G Y G Y W R Bu Bl G Y R Bl W Bl R G Y Bu R R Bl Bu Bl W Bl Y Y R Lg Y W Y Bu Bu R Bl W R R W Bl W R G Y R Y R Bu Bu R W Bl W Bl Bu Bl R Bl Y R Y R Bu G Y W Bu R W Bl Bu Bl R Bl Y G Y W Bu G Bu W P Bu Bl ...

Page 79: ...erequipment honda com support shop manuals Parts Catalog This manual provides complete illustrated parts lists for your generator Visit peparts honda com for free online access to the parts catalog It is also available for purchase in paper form through your Honda dealer Accessories Catalog Your authorized Honda Power Equipment dealer offers a wide selection of accessories optional equipment to ma...

Page 80: ...alership s management contact the Honda Power Equipment Customer Relations Office You can write to American Honda Motor Co Inc Power Equipment Division Customer Relations Office 4900 Marconi Drive Alpharetta Georgia 30005 8847 Or telephone 770 497 6400 1 888 888 3139 toll free M F 9 00am 7 30pm ET To email Honda visit powerequipment honda com support contact us When you write or call please give u...

Page 81: ...Virgin Islands from American Honda or a dealer authorized by American Honda to sell those products This warranty applies to first retail purchaser and each subsequent owner during the applicable warranty time period unless noted otherwise What American Honda will Repair or Replace Under Warranty American Honda will repair or replace at its option any part that is proven to be defective in material...

Page 82: ... normal business hours To locate a dealer near you visit our web site at http powerequipment honda com and click on Find a Dealer If you are unable to obtain warranty service or are dissatisfied with the warranty service you receive contact the owner of the dealership involved normally this will resolve the problem However if you should require further assistance write or call the Power Equipment ...

Page 83: ...r cleaner element clutch disc tire wheel bearing recoil starter rope cable belt cutter blade oil and grease 3 Cleaning adjustment and normal periodic maintenance work carburetor cleaning engine oil draining blade sharpening belt and cable adjustments 4 Any product that has ever been declared a total loss or sold for salvage by a financial institution or insurer 5 Auger and paddle assemblies skid s...

Page 84: ...any Honda Power Equipment parts accessories or apparel that are proven to be defective in material or workmanship under normal use during the applicable warranty time period Anything replaced under warranty becomes the property of American Honda Motor Co Inc The warranty on all parts accessories and apparel replaced under warranty will expire coincident with the original warranty on the replaced p...

Page 85: ... parts accessories or apparel affected or damaged by collision normal wear use in an application for which the product was not designed or any other misuse neglect incorporation or use of unsuitable attachments or parts unauthorized alteration improper installation or any causes other than defects in material or workmanship of the product Installing parts and accessories on non Honda products or e...

Page 86: ...be designed built and equipped to meet the State s stringent anti smog standards Honda must warrant the emissions control system on your power equipment engine for the periods of time listed below provided there has been no abuse neglect or improper maintenance of your small off road engine or equipment leading to the failure of the emissions control system Your emissions control system may includ...

Page 87: ...equipment engine or a part has failed due to abuse neglect improper maintenance or unapproved modifications You are responsible for presenting your power equipment engine to a Honda Power Equipment servicing dealer as soon as the problem exists The warranty repairs shall be completed in a reasonable amount of time not to exceed 30 days If you have any questions regarding your warranty rights and r...

Page 88: ...e property of Honda Only Honda approved replacement parts may be used in the performance of any warranty repairs and must be provided without charge to the owner A list of warranted parts is on the reverse side of this warranty statement All emission related parts are under warranty for the remainder of the warranty period Normal maintenance items such as spark plugs and filters that are on the wa...

Page 89: ...r problem However if you require further assistance contact the Honda office in your region EXCLUSIONS Failures other than those resulting from defects in material or workmanship are not covered by this warranty This warranty does not extend to emission control systems or parts that are affected or damaged by owner abuse neglect improper maintenance or unapproved modifications This warranty does n...

Page 90: ...NTY PARTS DESCRIPTION Fuel Metering Carburetor assembly includes starting enrichment system Oxygen sensor Throttle body Engine temperature sensor Engine control module Fuel injector Fuel regulator Intake manifold Evaporative Fuel tank Fuel cap Fuel lines for liquid and fuel vapors Carbon canister Canister mounting brackets Fuel line fittings Fuel strainer Fuel valve Fuel pump Fuel hose joint Canis...

Page 91: ...chase with Honda This allows us to contact you with any important updates regarding your generator Please note registration is not required to obtain warranty service You can register your generator by visiting the Honda Power Equipment website http powerequipment honda com reg Your information will remain confidential It will not be released to any other company or organization ...

Page 92: ...ible for compliance could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and...

Page 93: ...to an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This transmitter must not be co located or operated in conjunction with any other antenna or transmitter ...

Page 94: ...7 Check the Engine 33 Cleaning 61 CO MINDER CO Shut off System 22 COMPONENT CONTROL LOCATIONS 18 Connections to a Building s Electrical System 50 CONSUMER INFORMATION 77 CONTENTS 3 CONTROLS FEATURES 18 CONTROLS 20 CUSTOMER SERVICE INFORMATION 78 D DEALER LOCATOR INFORMATION 77 Distributor s Limited Warranty 79 E Eco Throttle Switch 21 ECO THROTTLE SYSTEM 49 Electric Shock Hazards 8 EMISSION CONTRO...

Page 95: ...AULT CO SENSOR LIFE INDICATOR FLASHING WHEN RUNNING THE ENGINE 69 FEATURES 25 Fire and Burn Hazards 9 Foam Air Filter Cleaning 56 Fuel Level Indicator 25 FUEL RECOMMENDATIONS 17 FUEL 15 Fuel 61 G GENERATOR SAFETY 6 Grip and Undergrip 31 Ground Terminal 25 H Honda PUBLICATIONS 77 HOW TO RESTART WHEN STOPPED BY CO MINDER CO SHUT OFF SYSTEM 41 I IMPORTANT SAFETY INFORMATION 6 INDEX 92 Information not...

Page 96: ...d Alarm Indicator 27 Output Indicator 26 P Parallel Operation Outlets 24 Please Register Your Generator 89 Q QUICK REFERENCE INFORMATION 97 R REFERENCE INFORMATION 90 Refuel With Care 9 REGISTRATION 89 REMOVAL FROM STORAGE 65 S SAFE OPERATING PRECAUTIONS 37 SAFETY LABEL LOCATIONS 11 Safety Precautions 53 SERIAL NUMBER LOCATION 70 SERVICING YOUR GENERATOR 52 Smartphone application 29 SPARK ARRESTER...

Page 97: ... STOPPING THE ENGINE with Bluetooth ENABLED SMARTPHONE 41 STOPPING THE ENGINE 40 STORAGE PRECAUTIONS 65 STORAGE PREPARATION 61 STORAGE 61 System Ground 50 T TAKING CARE OF UNEXPECTED PROBLEMS 67 TECHNICAL INFORMATION 70 THE IMPORTANCE OF MAINTENANCE 52 TRANSPORTING 66 V Vehicles and Transportation Hazards 10 W WIRING DIAGRAM 76 ...

Page 98: ...96 MEMO ...

Page 99: ... page 17 Engine Oil Type SAE 10W 30 API SJ or later or equivalent for general use see page 14 Maximum oil capacity 15 oz 0 46 L Spark Plug Type NGK CR6HSB Electrode Gap 0 024 0 028 in 0 6 0 7 mm Maintenance Before each use Check engine oil level Check air cleaner element First 20 hours Change engine oil Subsequent See MAINTENANCE SCHEDULE see page 54 ...

Page 100: ...n EU3200i 31Z45600 00X31 Z45 6000 GENERATOR Owner s Manual H i FM AH 英 PANTONE 186C K 背幅4 6mm EU3200i See page 13 for Initial Use Instructions 2021 Honda Motor Co Ltd All Rights Reserved C 00X31Z45 6000 00X31Z45 6000 ...

Reviews: