OPERATION
47
When operating generators in parallel operation, if one generator emits exhaust
toward the other, the CO-MINDER® (CO Shut-off System) of the generator that is
receiving the exhaust may stop the engine. Pay attention to the following for
placing generators in parallel operation.
• Align the two generators so that their mufflers are on the same line and exhaust in
the same direction.
• Place the generator so that the muffler is pointed in the same direction as the
wind is blowing and the exhaust is directed away from buildings, other structures,
or vehicles.
EXHAUST
EXHAUST
ON THE SAME LINE
WIND DIRECTION
WIND DIRECTION
This generator may detect exhaust from the
adjacent generator and will stop the engine.
OK
INCORRECT
MUFFLER