GENERATOR/CHARGING SYSTEM
8-27
INVERTER UNIT INSPECTION
Remove the inverter unit (page 8-7).
Check for continuity between the terminals using a
tester with diode measuring function according to the
tables below.
• Set the tester to the
mark position and
perform this inspection.
• The “no continuity” display varies on each tester.
When there is no continuity, the display shows the
same as it does when the tester is not used for
measurement (OL, OF, etc).
• Some testers have reverse polarity.
Unit: V
Unit: V
Unit: V
(-) Tester probe
Connec-
tor
(+)Tester pr
obe
Con-
nector
Terminal
5
1
0.3 - 0.8
3
0.3 - 0.8
(+) Tester probe
Connec-
tor
(-)Tester probe
Con-
nector
Terminal
1
1
0.3 - 0.8
3
0.3 - 0.8
(-) Tester probe
Connec-
tor
(+)Tester
probe
Con-
nector
Terminal
2
3
4
1
0.3 - 0.8
0.3 - 0.8
0.3 - 0.8
Viewed from terminal side
Viewed from terminal side
5
13
10
13
10
10