8-13
dummyhead
dummyhead
GENERATOR/CHARGING SYSTEM
GENERATOR INSPECTION
MAIN WINDING
Remove the control panel (page 8-6).
Disconnect the generator wire harness 5P connector
from the inverter unit.
Measure the resistance between the terminals of the
connector
according to the table below.
SUB WINDING
Remove the control panel (page 8-6).
Disconnect the generator wire harness 5P connector
from the inverter unit.
Measure the resistance between the terminals of the
connector
according to the table below.
EXCITER WINDING
Remove the control panel (page 8-6).
Measure the resistance between the terminals of the
connector
according to the table below.
Terminal number
Resistance
1 – 2
1.4 – 2.1
Ω
1 – 3
1.4 – 2.1
Ω
2 – 3
1.4 – 2.1
Ω
Terminal number
Resistance
4 – 5
0.3 – 0.5
Ω
Terminal number
Resistance
1 – 3
0.5 – 0.9
Ω
Summary of Contents for EU10iT1