1-3
dummyhead
dummyhead
SPECIFICATIONS
GENERATOR
CHARACTERISTICS
Model
EM10000K1
Type
SH
SKH
LDH
Description code
EBTC
Generator type
Double electrode field rotation type
Excitation
Self–excitation and power coil excitation
Voltage regulation system
Digital AVR (Automatic Voltage Regulator)
Phase
Single phase
Rotating direction
Counterclockwise (Viewed from the generator)
Rated
output
AC
9.0 kVA
DC
–
Rated frequency
60 Hz
AC
Rated
voltage
220 V
120 / 240 V
Rated
current
40.9 A
37.5 x 2 / 37.5 A
DC
Rated
voltage
–
Rated
current
–
Power factor
1.0 cos
θ
Model
EM10000K1
Type
SH
SKH
LDH
Voltage
variation
rate
Momentary
15% max.
Average
7% max.
Average
time
5 sec. max.
Voltage stability
± 1% max.
Frequency
variation
rate
Momentary
15% max.
Average
7% max.
Average
time
5 sec. max.
Frequency stability
± 1 Hz max.
Insulation resistance
10 M
Ω
min.
AC circuit protector
45 A
41 A
DC circuit protector
–
Insulation type
Type F
Fuel tank capacity
31.0 (8.19 US gal, 6.82 Imp gal)
Fuel consumption
at rated load
5.8 (1.53 US gal, 1.28 Imp gal) /Hr.
Max. operating hours
at rated load
5.3 Hr.
Sound power level (L
WA
)
at rated load
L
WA
103.4 dB(A)
Summary of Contents for EM10000K1
Page 22: ...MEMO dummyhead dummyhead ...
Page 23: ...7 1 7 dummytext 7 GOVERNOR SYSTEM GOVERNOR ARM CONTROL REMOVAL INSTALLATION 7 2 ...
Page 40: ...MEMO dummyhead dummyhead ...
Page 41: ...9 1 9 dummytext 9 IGNITION SYSTEM IGNITION COIL INSPECTION 9 2 ...
Page 52: ...MEMO dummyhead dummyhead ...
Page 58: ...MEMO dummyhead dummyhead ...