26
OPERATION
STOPPING THE ENGINE
To stop the engine in an emergency, simply turn the engine switch to
the OFF position securely. Under normal conditions, use the following
procedure.
1. Turn off or disconnect all appliances that are connected to the
generator.
2. Turn the engine switch to the OFF position securely.
Operating the generator in the FUEL OFF position before turning the
engine switch to the OFF position can reduce the fuel in the
carburetor.
• When using the FUEL OFF position, the generator will continue to
run for several minutes until the fuel in the carburetor has been
consumed, and then the engine will stop.
• Turn the engine switch to the OFF position after the engine stops.
• After stopping the engine using the FUEL OFF position, restarting
the engine will require additional pulls on the recoil starter.
3. Allow the engine to cool, and then turn the fuel filler cap vent lever
to the OFF position.
If the generator will not be used for a long period of time, refer to
page 52 for information on
Draining the Fuel Tank and Carburetor
.
ENGINE SWITCH
OFF
FUEL OFF
FUEL FILLER CAP VENT LEVER
OFF