ELECTRICAL INFORMATION
•
1 dedicated 12-2 wire with 20 amp GFCI breaker (220V)
•
Connect the overhead light, speaker, fan, CD, telephone according to the tags on the wires.
•
Do not connect the wire “O3” to anything.
•
Connect main power supply.
PLUMBING INFORMATION
The unit is equipped with 3 ft. hot and cold, metal braided water supply hose with ½-inch national pipe thread to connect from
faucet/manifold (Manifold is located. 4 ft. high on rear of unit) to the shutoff valves (should be installed where they can be accessed).
Note: base edge sets directly against back and sidewall. Do not install any pipes along walls as to impede the base from setting flush
against them.
•
Install hot and cold shutoffs with ½ -inch male national pipe thread (not included). Install shutoffs where they can be
accessible.
•
Access panel near controls, pumps, and jets is recommended
•
Drainage:
It is advised to have base onsite before preparing drain location. The diameter of the drain hole should be larger
or equal to Φ40mm (1 3/5 inches).
•
Note:
The flexible drain hose included with acrylic base is for installation into a floor drain only. Substituting the this drain
setup for a setup of the installers’ choice will not void the warranty of the unit as long as there is no evidence of misuse
or
damage to the base. If the substitute drain system is used, a 3/8 in stub must be added to the main shower drain line to
connect the steam generator’s automatic flushing drainage hose.
•
All fixtures and fittings must be checked for tightness as they may have been loosened during transport
PLUMBING REQUIREMENTS
•
The unit is equipped with h
ot and cold, metal braided water supply hoses with ½” national pipe threaded fitting.
•
Need to install hot and cold shutoffs with ½”
-male national pipe thread (not included).
•
All fixtures and fittings must be checked for tightness as they may have been loosened during transport
•
Note for Acrylic Base ONLY:
The flexible drain hose included with this unit is for installation into a floor drain only.
Substituting the existing drain setup for one of the installers’ choice will not void the warranty of the unit a
s long as there is
no evidence of misuse or damage to the base.
GENERAL INFORMATION
•
The main wall panel with water manifold and electrical equipment is designed to be installed on the left side of unit. If water
and electrical connections are on the right side, these side wall panels are interchangeable (please call Homeward Bath
technician before this is done). This must be completed onsite by installer.
•
Units come broken down in panels and are assembled with screws, nuts and bolts on site.
•
All Acrylic shower bases need to be leveled in its final resting position (all feet must be touching the ground), mark the
placement.
•
All Stone shower bases may need to be set and leveled in place on a bed of thin set mortar.
•
It is advised to have base onsite before preparing drain location.
•
Access near controls and jets is recommended.
Manufacturer reserves the right to change specs or features at any time.
Please check to confirm details. 1-866-783-2661
SHOWER PAN OPTIONS
The standard WS-112 shower enclosure does not include a base. It was designed so that it can be installed over an existing
base/floor of your choice of optional bases Homeward Bath provides.