Homewardbath GH21-HT Installation & Operation Manual Download Page 4

Choose your size of machine  

 
Measure the length, width, and height in feet of the current steam shower or bathtub room.  
Example; L:7 x W:5 x H:8 = 280 Cubic feet x 2 to get complete cubic measurement  

Note

: Multiplying the cubic feet by two is done to account for heat loss due to the room having natural stone such as 

granite or marble, exterior walls, ceiling height exceeding 8 feet, ceramic tile, or glass walls.  
Refer to the Parameter section to know if you have the correct size needed for your space. 
 

Parameter 

 

Power 

Space  

Voltage 

Max Current 

Wire DIA 

6kW 

140-320ft³ 

220-240V 

27.3A 

10# ro 6MM² 

9kW 

320-460ft³ 

220-240V 

41A 

10# ro 6MM² 

12kW 

460-700ft³ 

220-240V 

55A 

6# ro 10MM² 

18kW 

700-920ft³ 

Two 220-240V Lines 

Two 41A breakers 

Two 10# ro 6MM² lines 

24kW 

920-1400ft³ 

Two 220-240V Lines 

Two 55A breakers 

Two 6# ro 10MM² lines 

 

110-120V AC power supply for power module GH21-PB 

 

Single power box comes with every size of the generator.  Additional keypads and/or generators could be added 
to the same power box.  

Call for any clarification. 

 

Dimensions 

 

 

Size 

6/9kW 

10 3/8in 
(263.5mm) 

7 7/8in 
(200mm) 

13 1/8in 
(333mm) 

10 7/16in 
(264.5mm) 

14 5/8in 
(372mm) 

12kW 

10 3/4in 
(260mm) 

9 3/8in 
(238mm) 

16 1/8in 
(409mm) 

10 7/16in 
(264.5mm) 

14 5/8in 
(372mm) 

 

 

Summary of Contents for GH21-HT

Page 1: ...Steam Planet Superior Encore Steam Generator Installation Operation Manual 6kW 9kW 12kW 18kW 24kW Rev 6 2022...

Page 2: ...ule Introduction 7 Reset Introduction 7 Choosing the proper location 8 Keypad Diagram 8 Keypad Introduction 9 Dual Keypad Setup 10 Common Installation Problems 11 Suggested Steam Room Layout 11 Instal...

Page 3: ...tering or leaving b The steam head is hot Do not touch the steam head and avoid the steam near the steam head c Prolonged use of the steam system can raise excessively the internal human body temperat...

Page 4: ...er Power Space Voltage Max Current Wire DIA 6kW 140 320ft 220 240V 27 3A 10 ro 6MM 9kW 320 460ft 220 240V 41A 10 ro 6MM 12kW 460 700ft 220 240V 55A 6 ro 10MM 18kW 700 920ft Two 220 240V Lines Two 41A...

Page 5: ...ed 11ft power cable External temperature sensor External temperature sensor foundation 12ft power box extension cable 9 5ft cable for keypad or generator connection 1ft light cable 25ft cable for sing...

Page 6: ...Wiring Diagram...

Page 7: ...V with 2 pin SIM2 54 connector Module Introduction The system consists of power box GH21 PB control module GH21EE Bluetooth module GH21 BT and steam module GS08 HW Power box GH21 PB provides 14v DC Th...

Page 8: ...ft between steam generator and any other object 9 The place where the machine is installed must be accessible for cleaning and possible service work 10 The steam generator should be in a close proximi...

Page 9: ...Keypad Introduction...

Page 10: ...e Icon is highlighted on the keypad the current temperature will be displayed 2 Press and hold the dial in the steam room temperature will be displayed and the thermometer in the display will start to...

Page 11: ...e reading Power box issues Make sure the wiring that connects the power box to the keypad and steam generator is not damaged Suggested Steam Room Layout Installation 1 For wall mounting Steam generato...

Page 12: ...ctor b Drain G1 2 thread connector Must be copper for at least first 3ft from the generator c Steam outlet G3 4 thread connector d Steam line Must use copper Insulate the line with high temp 212 plus...

Page 13: ...ture resistant material Outlet should be no closer than 10in from the floor and no higher that 15in from the floor The steam outlet should be installed face down Wrap a few circles Teflon tape around...

Page 14: ...Circuit Diagram for 6kW 9kW...

Page 15: ...Circuit Diagram for 12kW...

Page 16: ...ning Both openings go to the tank Fill the tank until the solution starts to come out of the steam outlet or the pressure relief valve opening Replace the steam line or the pressure relief valve then...