HomeSeer | 10 Commerce Park North, Unit 10 | Bedford, NH 03110 | HomeSeer.com | Doc: HS
-
MS100
-
en
-
v2
HS
-
MS100+ Z
-
Wave Motion Sensor
Applications
•
Activate Z
-
Wave wall switches or plug
-
in modules when motion is sensed.
•
Trigger home automation events when motion is sensed.
Configuration
The unit may be powered using the included battery or with a USB power adapter (not included). The unit includes a Z
-
Wave
network button for inclusion/exclusion and a blue LED operation indicator. A magnetic mount allows for very easy installation.
Z
-
Wave Network Installation
Remove the back cover by rotating counter
-
clockwise and Install 1 CR123A battery (included) inside the unit. Alternately, you
may power the unit with a micro USB connection. HS
-
MS100+ may be included into your Z
-
Wave network as a
“
secure
”
device
or as a
“
non
-
secure
”
device. Use the instructions below to
include
or
exclude
HS
-
MS100+ to/from your Z
-
Wave network.
Standard Inclusion
(recommended for best compatibility)
1.
Put your home controller into Z
-
Wave
‘
inclusion
’
mode.
2.
Quickly press and release the Z
-
Wave network 2 times. Wait for the inclusion process to finish.
Secure S2 Inclusion
(recommended ONLY if your home controller supports
“
S2
”
Z
-
Wave encryption)
1.
Put your home controller into Z
-
Wave
‘
inclusion
’
mode.
2.
Quickly press and release the Z
-
Wave button 3 times. Wait for the inclusion process to finish.
Repeater Inclusion
(recommended ONLY if sensor is powered externally with micro USB adapter)
1.
Press the Z
-
Wave button for 3 to 5 seconds and release. Wait for the inclusion process to finish. The sensor is added as a Z
-
Wave repeater. Note that you must run the sensor on line power or the batteries will be exhausted quickly.
Exclusion
1.
Put your home automation controller into Z
-
Wave
‘
exclusion
’
mode.
2.
Quickly triple
-
press the Z
-
Wave network button. Wait for the exclusion process to finish.
Reset
(Use this procedure to reset HS
-
MS100+ to factory settings when the Z
-
Wave controller is missing or inoperable).
1.
Press and hold the Z
-
Wave button for 20 seconds. Release the button once the LED stops blinking and glows solidly.
Physical Installation
Install the magnetic mount in the location of your choice using the supplied double
-
stick tape or screw. Then attach the main
unit to the mount and point the sensor dome, the lens, toward the location you wish to monitor.
Motion Sensor Operation
HS
-
MS100+ is designed to transmit a Z
-
Wave command when motion is sensed. It will also transmit another command when
motion has not been sensed for a period of time. This
“
motion timeout
”
interval is adjustable using a Z
-
Wave parameter (see
page 2). The default setting of 600 seconds (10 minutes) should yield a good balance of performance and battery life.
Shock Sensor Operation
The shock sensor is designed to transmit a Z
-
Wave command when HS
-
MS100+ has been physically moved. This sensor is espe-
cially helpful in determining whether the unit has been removed from its mount or tampered with.
OVERVIEW
HS
-
MS100+ is a compact, easy to install motion sensor. It is designed to control other Z
-
Wave devices directly or it may be used
with a variety of Z
-
Wave certified home controllers to launch automation events or scenes.