55
Start-up
6.2
Installation
To install the floor heating actuator, please proceed as
follows:
• Open the cover
(D)
. Therefore, release the catch
under the slot for opening
(C)
by pushing it with
a screwdriver. Remove the cover by pulling it up-
wards (
see fig. 5
).
• Connect the transformer to the connecting ter-
minals
(F)
of the floor heating actuator.
Press the terminal down using an appropriate
screw driver to open the connecting terminal.
Thread the corresponding cable. Release the ter-
minal to close it and to fix the cable (
see fig. 6)
.
• Plug in the connecting cable of the valve actu-
ators in your heating circuits to the connecting
terminals
(G-H)
. Connect a heating pump using
connecting terminal
(G)
.
• Make sure that all connecting cables are fixed
properly to the cable bushings before closing the
cover.
• Close the cover again. Therefore, push the latch-
es of the cover into the openings provided and
press it down.
• Plug the mains plug of the transformer into a
socket.
Summary of Contents for HmIP-FAL24-C6
Page 3: ...1 A G B E C H D F ...
Page 4: ...2 3 K I J ...
Page 5: ...4 5 ...
Page 6: ...6 7 Selecttaste drücken Systemtaste drücken press select button press system button ...