Page 2: ...installation of this product read the package list on page 2 and ensure all parts are present and display no defects If any part is missing or damaged contact customer service and do not attempt to install the product Read all of the safety information on page 3 before installation or use Estimated assembly time 120 minutes Additional tools required for assembly Electrical tape flathead Phillips s...

Page 3: ...pling Cover f Fan Motor Assembly g Light Plate h LED Light Kit i Glass Shade j Remote Control k Receiver l Mounting Screws 4 Mounting Bolts 2 Spring Washers 4 Star Washers 4 Blade Bolts 7 Flat Washers 14 Wire Nuts 10 Balance Kit PACKAGE CONTENTS a b c d f g e h i k j l ...

Page 4: ...and pushed carefully up into outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box 7 The fan must be mounted with a minimum of 7 feet clearance from the trailing edge of the blades to the floor 8 Do not use the reverse switch while the fan blades are in motion To prevent damage and ensure long use the fan must be...

Page 5: ...ings Do not use on slanted surfaces 7 feet 30 inches 1 Turn Off Your Power Begin installation by removing fuses or turning off circuit breakers to the wiring you will be using Use your compatible UL listed outlet box if you already have one installed 2 Choose Your Mounting Position If you need to install a new UL listed outlet box secure it directly to your building s structure usingappropriate fa...

Page 6: ...he fan motor through the downrod Install the downrod onto the coupling Step 3 Insert the hitch pin through the downrod and then re install the retaining clip Retighten the bolts Step 4 Place the downrod ball into the ceiling mounting bracket socket Rotate the entire assembly until the tab has dropped into its slot and sits firmly The entire motor assembly should not rotate left or right when seate...

Page 7: ...o the 5 identically colored lead wires from the fan motor Secure each set with the provided wire nuts Step 3 Connect the 2 colored wires from the remote receiver to the 2 identically colored lead wires from the outlet box Secure each set with the provided wire nuts Step 4 Connect the green or bare copper ground wire from the outlet box to the ground wires from the ceiling mounting bracket and the ...

Page 8: ...n the bolts Step 3 Repeat for the remaining blades Step 1 Tuck all the connections neatly into the outlet box Step 2 Slide the canopy up to the ceiling mounting bracket and place the key hole slots over the mounting screws or bolts on the bracket Rotate the canopy until the screw or bolt heads lock in place at the narrow section of the key hole Ceiling Mounting Bracket Canopy Mounting Screws Bolts...

Page 9: ...olor temperature in order Repeat these steps to cycle through the 3 color temperatures Step 1 Remove the pre installed bolts on the fan motor assembly Step 2 Feed the wire connectors through the middle of the light plate Install the light plate onto the motor assembly and secure it by replacing and retightening the bolts Step 3 Connect the LED light kit to the light plate using its magnetic suctio...

Page 10: ...Turns the light on or off Runs the fan for 1 hour and then turns it off Runs the fan for 2 hours and then turns it off Runs the fan for 4 hours and then turns it off Reverses the fan s direction Key Function LOW MED HI STOP LIGHT 1H 2H 4H F R Install the remote control holder onto any wall or suitable flat surface using the two steel screws Upon first use connect the remote control to its receiver...

Page 11: ... in Cut off power to the fan and check that the wire nut connections are not rubbing against one another or the inner housing If you have installed a solid state variable speed control cut off power to the fan and disconnect this control from the device See if using the remote resolves the problem which can be caused by erratic signals from such controls Check that all bolts screws and fasteners a...