Pre-Installation
INSTALLATION REQUIREMENTS
WARNING:
Electrical Shock Hazard
□
Plug into a grounded 3-prong outlet.
□
Do not remove ground prong.
□
Do not use an adapter.
□
Do not use an extension cord.
□
Failure to follow these instructions can result in death, fire, or electrical shock.
RECOMMENDED GROUNDING METHOD
This air conditioner must be grounded. This air conditioner is equipped with a power supply cord with a three-prong grounding plug. The
cord must be plugged into a three-prong outlet, grounded in accordance with all local codes and ordinances. If a grounded outlet is not
available, it is the customer’s responsibility to have a properly grounded three-prong outlet installed by a qualified electrical installer.
It is the customer’s responsibility:
□
To contact a qualified electrical installer.
□
To assure that the electrical installation is adequate and conforms to the Nation Electrical Code, ANSI/NFPA 70-last edition, and all local
codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Ma 02169-7471
www.nfpa.org
WIRING REQUIREMENT
115 V (103.5 V min. to 126.5 V max.)
10 A time-delay fuse or circuit breaker
POWER SUPPLY CORD
1
2
NOTE:
Your air conditioner’s device may differ from the one shown. This room air conditioner
is equipped with a power supply cord required by UL. This power supply cord contains state-
of-the-art electronics that sense leakage current. If the cord is crushed, the electronics detect
leakage current and power will be disconnected in a fraction of a second.