Operation

AIR CONDITIONER USE

IMPORTANT:

 

 

If you turn off the air conditioner, wait at least 3 minutes before turning it back on. This prevents the air conditioner from 
blowing a fuse or tripping a circuit breaker.

 

Air conditioner in the Cool mode operation the better limits: Outdoor 64.4-109.4°F (18-43 °C), 80% RH; indoor 62.6-89.6°F 
(17-32°C), 80% RH.

 

Operating your air conditioner properly helps you to obtain the best possible results.

 

This section explains proper air conditioner operation.

Power

 

Press the power button to turn on the air conditioner.

NOTE:

 Wait 3 minutes before restarting the appliance to 

prevent damaging the compressor.

Fan Speed

 

Use the Fan Speed button to select your choice of fan 
speeds for air circulation.

 

Choose High or Low.

 

High - for maximum cooling

 

Low - for quieter cooling

Fan Only

 

Fan Only mode. Press Fan Speed to select High or Low.

NOTE:

 In Fan Only mode, the compressor will not run.

Summary of Contents for 1007086606

Page 1: ...hance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Vissani USE AND CARE GUIDE WINDOW AIR CONDITIONER Questions problems m...

Page 2: ...g requirement 4 Power Supply Cord 4 Pre Installation 4 Planning Installation 5 Hardware Included 6 Unpack the Air Conditioner 7 Location Requirements 7 Window Installation 9 If AC is Blocked by Storm...

Page 3: ...compressor This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given sup...

Page 4: ...qualified electrical installer It is the customer s responsibility To contact a qualified electrical installer To assure that the electrical installation is adequate and conforms to the Nation Electr...

Page 5: ...oper operation The power supply cord must be replaced if it fails to trip when the test button is pressed or fails to reset Do not use the power supply cord as an off on switch The power supply cord i...

Page 6: ...C CC DD DD EE EE FF FF II II KK KK JJ JJ GG GG Part Description Quantity AA Adhesive seal 2 BB Foam seal 1 CC Sealing sponge 1 DD Lock frame for wooden windows 2 EE Lock frame for vinyl Clad windows 2...

Page 7: ...ng alcohol flammable fluids or abrasive cleaners to remove tape or glue These products can damage the surface of your air conditioner Handle the air conditioner gently Remove top rail II from the pack...

Page 8: ...verning codes and ordinances Check the location where air conditioner will be installed Proper installation is your responsibility Make sure you have everything necessary for correct installation The...

Page 9: ...he electrical outlet must be within reach of the power cord Follow the dimensions in the table and illustration for your model Models A B 5KBTU 12 2 5 inch 315 mm min 22 inch 559 mm 37 4 5 inch 960 mm...

Page 10: ...and then bottom of right hand curtain housing A in top and bottom curtain rails B on air conditioner B B B A A A A A A B B B Slide the curtain housing into the channels as far as it will go Repeat ab...

Page 11: ...el Do not block the louvers on the outside of the air conditioner Center air conditioner in window Lower the window sash A behind the top rail to hold cabinet in place Keep a firm grip on the air cond...

Page 12: ...inst the glass of the upper window A B Use a 1 8 inch 3 mm drill bit to drill a starter hole through the hole in the top rail Attach top channel to window sash with one 3 4 inch 19 mm screw to secure...

Page 13: ...6 89 6 F 17 32 C 80 RH Operating your air conditioner properly helps you to obtain the best possible results This section explains proper air conditioner operation 1 Power Press the power button to tu...

Page 14: ...er cool settings will provide higher room temperature NOTE The controls featured in this manual are representative of many available models Your model may offer slightly different features 5 Changing...

Page 15: ...he filter out from the right hand side of the front panel A Use a vacuum cleaner to clean the air filter A If the air filter is very dirty wash it in warm water with a mild detergent Do not wash the a...

Page 16: ...d on the same circuit Unplug or relocate appliances that share the same circuit Time delay fuse or circuit breaker of the wrong capacity is be ing used Replace with a time delay fuse or circuit breake...

Page 17: ...air conditioners are not designed to cool multiple rooms The filter is dirty or obstructed by debris Clean the filter The inside evaporator and outside condenser coils are dirty or obstructed by debri...

Page 18: ...roblems missing parts Before returning to the store call Vissani Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 877 527 0313 HOMEDEPOT COM Retain this manual for future use...

Reviews: