Home HME030343N Manual Download Page 1

Window AC

HME030343N

Thank

 you 

for

 selecting our

 quality

 appliance. Please be sur

to r

ead 

this user

 manual

 

car

efull

y be

for

e using. 

An

y question, please con

tact 

the pr

of

essional

 service 

for

 help

.

Summary of Contents for HME030343N

Page 1: ...Window AC HME030343N Thank you for selecting our quality appliance Please be sure to read this user manual carefully before using Any question please contact the professional service for help ...

Page 2: ...roughout their journey Please leave it standing upright and outside the box for 24 HOURS before plugging it in In the event this product malfunctions or customer believes it is defective the customer should contact Customer Service and retain the defective product pending further instructions Defective product should be clearly marked or stored where it cannot be used again by mistake Failure to r...

Page 3: ... appliance Congratulations Don t forget to register your product at homelabs com reg for updates coupons and other relevant information Although greatly appreciated product registration is not required to activate any warranty ...

Page 4: ...e air conditioner The handling installation storage servicing and disposal must comply with the provisions of gas related national laws and regulations and also national wiring regulation It is necessary to clear away the refrigerant in the system when maintaining or scrapping an air conditioner Be aware that refrigerants may not contain an odor This appliance is not intended for use by persons in...

Page 5: ...ments Power Supply Cord 15K LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI Leakage Current Detection and Interruption power cord that is required by UL This power supply cord contains state of the art electronics that sense leakage current If the cord is damaged and leakage occurs power will be disconnected from the unit The test and reset buttons on the LCDI Plug are used ...

Page 6: ...ord Grounding type wall receptacle Power supply cord with 3 prong grounding plug and current detection device Do not under any circumstances cut remove or bypass the grounding prong INSTALLATION ASSEMBLY INSTRUCTIONS Window Preparation Please read all instructions prior to installing your air conditioner Two people are recommended to install this product If a new electrical outlet is required have...

Page 7: ...tlet The power supply must be the same as shown on the unit serial nameplate located on the left side of the unit near the front faceplate Be sure the outlet is close enough for the power cord to reach 3 Carefully unpack the air conditioner Remove all packing material and make sure the floor is protected when removing Due to the large size of this air conditioner two people should move the unit to...

Page 8: ...rating Instructions Top Angle Rail and Side Bracket Installation The top rail must be assembled prior to installing the air conditioner in the window Tools Needed Phillips Screw Driver Top Rail Hardware QTY 5 16 Long Hex head Screw 4 Top Rail 1 Attaching the Top Rail to the Air Conditioner 1 Remove the air conditioner from the box and place on a hard flat surface 2 Remove top rail from the bottom ...

Page 9: ...to the support brackets at the marked position as shown above Hand tighten but not all the way for any changes that may need to be made later during installation 3 Install the support brackets with sill angle brackets attached to the bottom of the cabinet as shown below 4 Tighten all 6 bolts securely Long Flat head Bolt and Locknut Extend the Accordion Panels 1 Carefully raise the window to expose...

Page 10: ...wing dimensions depending on your model WIDTH X inside model plus twice the thickness of the framing material used HEIGHT Y inside model height plus twice the thickness of framing material used Model 15K Inside Frame Height 18 1 4 46 4 cm Inside Frame Width 23 7 8 60 6 cm Y FIG 11 4 Build a wooden frame with the INSIDE dimensions of your model listed above Measure twice The frame depth should be t...

Page 11: ...bstructions 4 Install the exterior cabinet support brackets according to the SUPPORT BRACKET INSTALLATION instructions in the THRU THE WALL installation section Caulk or flash with aluminum if needed This will provide a tight seal around the top and sides of the cabinet Operating Instructions USING YOUR AIR CONDITIONER Electronic Control Panel Remote Control NOTE This display always shows the room...

Page 12: ...rn off or on in 0 5 24 hours Each press of the buttons will increase or decrease the timer in 0 5 hour increment below 10 hours and 1 hour increment for 10 hours or above The SET light will turn on while setting To cancel the Timer function press the TIMER button again 6 Eco Button When the unit is in ECO mode the light will turn on In ECO mode the unit will turn off once the room is cooled to the...

Page 13: ...the unit will turn off once the room is cooled to the set temperature The unit will turn back on when the room temperature rises above the set temperature Before the compressor starts the fan motor will turn on and off repeatedly to provide comfortable feeling and save energy 10 FAN ONLY Press the FAN ONLY button if you need Fan Only mode Cleaning and Maintenance Clean your air conditioner to keep...

Page 14: ...ce hOme offers a limited two year warranty warranty period on all of our products purchased new and unused from hOme Technologies LLC or an authorized reseller with an original proof of purchase and where a defect has arisen wholly or substantially as a result of faulty manufacture parts or workmanship during the warranty period The warranty does not apply where damage is caused by other factors i...

Page 15: ... 2016 hOme Technologies LLC 37 East 18 Street 7th Floor New York NY 10003 For household Use Only 1 800 898 3002 help homelabs com homelabs com help All rights reserved hOme Printed in China ...

Reviews: