Single Pulse Mode
To select this mode, bits TnM1 and TnM0 in the TMnC1 register should be set to 10 respectively
and also the TnIO1 and TnIO0 bits should be set to 11 respectively. The Single Pulse Output Mode,
as the name suggests, will generate a single shot pulse on the TM output pin.
The trigger for the pulse output leading edge is a low to high transition of the TnON bit, which can
be implemented using the application program. However in the Single Pulse Mode, the TnON bit
can also be made to automatically change from low to high using the external TCKn pin, which will
in turn initiate the Single Pulse output. When the TnON bit transitions to a high level, the counter
will start running and the pulse leading edge will be generated. The TnON bit should remain high
when the pulse is in its active state. The generated pulse trailing edge will be generated when the
TnON bit is cleared to zero, which can be implemented using the application program or when a
compare match occurs from Comparator A.
However a compare match from Comparator A will also automatically clear the TnON bit and thus
generate the Single Pulse output trailing edge. In this way the CCRA value can be used to control
the pulse width. A compare match from Comparator A will also generate a TM interrupt. The counter
can only be reset back to zero when the TnON bit changes from low to high when the counter
restarts. In the Single Pulse Mode CCRP is not used. The TnCCLR and TnDPX bits are not used in
this Mode.