Rev. 1.40
12
March 29, 2019
Rev. 1.40
13
March 29, 2019
HT45F23A/HT45F24A
TinyPower
TM
Flash MCU with OPA & Comparators
HT45F23A/HT45F24A
TinyPower
TM
Flash MCU with OPA & Comparators
Absolute Maximum Ratings
Supply Voltage ................................................................................................
V
SS
−0.3V to V
SS
+6.0V
Input Voltage ..................................................................................................V
SS
−
0.3V to V
DD
+0.3V
Storage Temperature ....................................................................................................-50
˚C to 125˚C
Operating Temperature ..................................................................................................-40
˚
C to 85
˚
C
I
OL
Total ................................................................................................................................... 100mA
I
OH
Total ..................................................................................................................................-100mA
Total Power Dissipation ......................................................................................................... 500mW
Note: These are stress ratings only. Stresses exceeding the range specified under "Absolute Maximum
Ratings" may cause substantial damage to these devices. Functional operation of these devices at
other conditions beyond those listed in the specification is not implied and prolonged exposure to
extreme conditions may affect devices reliability.
D.C. Characteristics
Ta=25
˚
C
Symbol
Parameter
Test Conditions
Min. Typ. Max. Unit
V
DD
Conditions
V
DD
Operating Voltage
—
f
SYS
=910kHz,
(HXT/ERC/HIRC)
2.2
—
5.5
V
f
SYS
=2MHz,
(HXT/ERC/HIRC)
2.2
—
5.5
V
f
SYS
=4MHz,
(HXT/ERC/HIRC/EC)
2.2
—
5.5
V
f
SYS
=8MHz
(HXT/ERC/HIRC/EC)
3.3
—
5.5
V
I
DD1
Operating Current
(HXT, ERC)
3.3V
No load, f
SYS
=f
M
=455kHz,
ADC off, LVR off,
Comparator off, OPAs off
—
70
110
µA
Operating Current
(HXT, ERC)
No load, f
SYS
=f
M
= 455kHz,
ADC off, LVR on,
Comparator on, OPAs off
—
100
150
µA
I
DD2
Operating Current
(ERC, HIRC)
3.3V
No load, f
M
=910kHz,
f
SYS
=f
SLOW
=455kHz,
ADC off, LVR off,
Comparator off, OPAs off
—
90
135
µA
Operating Current
(ERC, HIRC)
No load, f
M
=910kHz,
f
SYS
=f
SLOW
=455kHz,
ADC off, LVR on,
Comparator on, OPAs off
—
120
180
µA
I
DD3
Operating Current
(ERC, HIRC)
3.3V
No load, f
SYS
=f
M
=910kHz,
ADC off, LVR off,
Comparator off, OPAs off
—
110
170
µA
Operating Current
(ERC, HIRC)
No load, f
SYS
=f
M
=910kHz,
ADC off, LVR on,
Comparator on, OPAs off
—
160
240
µA
I
DD4
Operating Current
(HXT, ERC)
3.3V
No load, f
SYS
=f
M
=1MHz,
ADC off, LVR off,
Comparator off, OPAs off
—
120
180
µA
Operating Current
(HXT, ERC)
No load, f
SYS
=f
M
=1MHz,
ADC off, LVR on,
Comparator on, OPAs off
—
170
260
µA