background image

Programming the Essex Keypad

Note

: If the User ID, or User Code/PIN has not been assigned, you will hear one long beep 

when #  is entered.  

Reset Keypad to Factory Defaults--- This is not normally necessary, but can be done as follows

STEP

ACTION                                                                     BEEP          Red LED

Green LED

1

The default Master Code is “123”

.

This can be changed to a unique code  3 - 8 digits long.

2

Enter 

*3 1 2 3

#

Double Beep          Slow Flash         Solid

3

Enter 

#

Double Beep          Slow Flash

Slow Flash

4

Enter the desired activation time in 

Seconds

followed by 

#

Triple Beep            Slow Flash

Solid

5

Enter 

* *

to exit

6

Example:

2 # 10 # 

* *

(10 second activation time)

Setting Main Relay Opening Time

STEP

ACTION                                                                     BEEP          Red LED

Green LED

1

Remove power 

2

Jumper the “CONFIG”  pins on the rear of the keypad

3

Apply 12 VDC power to red and black wires ONLY

Quadruple Beep       Flash                      Solid

5

Enter 

0 0 9 9 

#

Double Beep             Flash

3 Sec Flash

6

WAIT about 4 seconds

Quadruple Beep        Flash                      Solid

7

Enter 

9 9 

#

Triple Beep                Flash 

Solid

8

Remove power

9

Remove “CONFIG” jumper

10

Reapply  power

Page 7

TYPE 6.2.0.1-RF

Summary of Contents for 400-S12-PAN

Page 1: ...ccess Control Essex stand alone 12 button keypad 1 relay plus 2 grounding outputs external relays required 500 users 12 VDC power supply included INSTALLATION INSTRUCTIONS 501 E Goetz Ave Santa Ana Ca 92707 www eholovision com Ph 714 434 6904 Fax 800 362 0002 HOLOVISION 400 Series S 12 Junction Board 12 VDC input for camera and keypad NO COM NC relay connections Keypad case ground Remote bypass te...

Page 2: ... absorb inductive kick back which can be created when power is removed from the strike Loop is required from DC positive to contact common for DC voltage to strike Essex Keypad Wiring DC Out for Gate Strike Page 2 Type 6 2 0 1 RF CO Line In To Phones KSU Strike 1 Door 1 Cut for NO Contact Closure AC Loop for Strike Remote Bypass Button ...

Page 3: ...Essex Keypad Wiring Contact Closure for Gate Operation 12vDC 1 5 A Page 3 Type 6 2 0 1 RF CO Line In To Phones KSU Strike 1 Door 1 Cut for NO Contact Closure AC Loop for Strike ...

Page 4: ...e Beep Fast Flash Slow Flash 4 Enter new master code followed by Triple Beep Fast Flash Solid 5 Enter Double Beep 6 EXAMPLE old code is 123 new code is 456 3 1 2 3 1 4 5 6 Set Master Code STEP ACTION BEEP Red LED Green LED 1 Remove power 2 Jumper the CONFIG pins on the rear of the keypad V 12 3 Apply 12 VDC power to red and black wires Quadruple Beep Flash Solid 4 Enter 9 9 followed by Double Beep...

Page 5: ... Triple Beep Slow Flash Slow Flash 10 Enter Double Beep X 2 Set User Codes STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step Master Code 123 is used as an example 2 Enter 1 1 2 3 Double Beep Slow Flash Solid 3 Enter 2 Double Beep Slow Flash Slow Flash 4 Enter User ID to be changed 1 500 followed by Double Beep Slow Flash Fast Flash 5 Enter new User Code PIN followed...

Page 6: ...te programming Triple Beep Slow Flash Slow Flash 7 Enter Double Beep X 2 Deleting User Codes using User Code PIN STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step In this example the Master Code is 123 2 Enter 1 1 2 3 Double Beep Slow Flash Solid 3 Enter 4 Double Beep Slow Flash Slow Flash 4 Enter 1st User ID to be deleted 1 500 followed by Triple Beep Slow Flash Fa...

Page 7: ...2 Double Beep Slow Flash Slow Flash 4 Enter the desired activation time in Seconds followed by Triple Beep Slow Flash Solid 5 Enter to exit 6 Example 2 10 10 second activation time Setting Main Relay Opening Time STEP ACTION BEEP Red LED Green LED 1 Remove power 2 Jumper the CONFIG pins on the rear of the keypad 3 Apply 12 VDC power to red and black wires ONLY Quadruple Beep Flash Solid 5 Enter 0 ...

Page 8: ...501 E Goetz Ave Santa Ana Ca 92707 Ph 714 434 6904 Fax 800 362 0002 www eholovision com ...

Reviews: