Manual Type 6.2.0.1-RF

“Panasonic Compatible” Unit with Essex 

“S-12 Stand - Alone” Keypad

For Models

400-S12-PAN        401-S12-PAN
403-S12-PAN        404-S12-PAN
410-S12-PAN        411-S12-PAN

Specifications

Communication

For use with all Panasonic KSUs with door phone
card. This unit is a replacement for the Panasonic
KXT-30865 door phone. 

Access Control

Essex “stand-alone” 12 button keypad
1 relay plus 2 grounding outputs 
(external relays required)
500 users
12 VDC power supply included

INSTALLATION

INSTRUCTIONS

501 E. Goetz Ave.

Santa Ana, Ca 92707

www.eholovision.com

Ph. 714-434-6904

Fax 800-362-0002

HOLOVISION

400 Series “S-12” Junction Board

12 VDC input (for camera and keypad)

NO, COM, NC relay connections

Keypad case ground

Remote bypass terminals (activate relay)

Connect tamper switch to alarm (optional)

Intercom to KSU

Cut for NO Contact Closure

Loop for Strike Power

Summary of Contents for 400-S12-PAN

Page 1: ...ccess Control Essex stand alone 12 button keypad 1 relay plus 2 grounding outputs external relays required 500 users 12 VDC power supply included INSTALLATION INSTRUCTIONS 501 E Goetz Ave Santa Ana Ca 92707 www eholovision com Ph 714 434 6904 Fax 800 362 0002 HOLOVISION 400 Series S 12 Junction Board 12 VDC input for camera and keypad NO COM NC relay connections Keypad case ground Remote bypass te...

Page 2: ... absorb inductive kick back which can be created when power is removed from the strike Loop is required from DC positive to contact common for DC voltage to strike Essex Keypad Wiring DC Out for Gate Strike Page 2 Type 6 2 0 1 RF CO Line In To Phones KSU Strike 1 Door 1 Cut for NO Contact Closure AC Loop for Strike Remote Bypass Button ...

Page 3: ...Essex Keypad Wiring Contact Closure for Gate Operation 12vDC 1 5 A Page 3 Type 6 2 0 1 RF CO Line In To Phones KSU Strike 1 Door 1 Cut for NO Contact Closure AC Loop for Strike ...

Page 4: ...e Beep Fast Flash Slow Flash 4 Enter new master code followed by Triple Beep Fast Flash Solid 5 Enter Double Beep 6 EXAMPLE old code is 123 new code is 456 3 1 2 3 1 4 5 6 Set Master Code STEP ACTION BEEP Red LED Green LED 1 Remove power 2 Jumper the CONFIG pins on the rear of the keypad V 12 3 Apply 12 VDC power to red and black wires Quadruple Beep Flash Solid 4 Enter 9 9 followed by Double Beep...

Page 5: ... Triple Beep Slow Flash Slow Flash 10 Enter Double Beep X 2 Set User Codes STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step Master Code 123 is used as an example 2 Enter 1 1 2 3 Double Beep Slow Flash Solid 3 Enter 2 Double Beep Slow Flash Slow Flash 4 Enter User ID to be changed 1 500 followed by Double Beep Slow Flash Fast Flash 5 Enter new User Code PIN followed...

Page 6: ...te programming Triple Beep Slow Flash Slow Flash 7 Enter Double Beep X 2 Deleting User Codes using User Code PIN STEP ACTION BEEP Red LED Green LED 1 The Master Code is necessary to do this step In this example the Master Code is 123 2 Enter 1 1 2 3 Double Beep Slow Flash Solid 3 Enter 4 Double Beep Slow Flash Slow Flash 4 Enter 1st User ID to be deleted 1 500 followed by Triple Beep Slow Flash Fa...

Page 7: ...2 Double Beep Slow Flash Slow Flash 4 Enter the desired activation time in Seconds followed by Triple Beep Slow Flash Solid 5 Enter to exit 6 Example 2 10 10 second activation time Setting Main Relay Opening Time STEP ACTION BEEP Red LED Green LED 1 Remove power 2 Jumper the CONFIG pins on the rear of the keypad 3 Apply 12 VDC power to red and black wires ONLY Quadruple Beep Flash Solid 5 Enter 0 ...