AccuSet Plus
TM
HUMIDISTAT INSTRUCTIONS
To take advantage of the AccuSet Plus
TM
Digital Humidistat, press
the MODE/OFF (
) button until the speed is set in either the
auto HIGH (A3), auto MEDIUM (A2) or auto LOW (A1) setting.
Then adjust the set humidity by using the up and down buttons.
Humidity will increase in increments of 5%. When the humidity
level is set, the display will return to show the current room
humidity. When the room humidity level rises above the set
humidity, the humidifier will stop. When the humidity level drops
below the set humidity, the humidifier will turn on automatically.
NOTE:
Allow up to 30 minutes for the filter to fully absorb
water and for the unit to produce moisture.
NOTE:
The AccuSet Plus
TM
Humidifier has memory. This
means that when you turn the unit back on, it will be at the
last setting the humidifier was set at.
If you do not plan to use the humidifier for two or more days,
make sure any residual water is drained from the water tank,
base and wick filter to prevent algae or bacteria growth.
Extended Run Time Setting:
By setting your humidifier to a specific humidity level, you
are actually also extending the run time. Since the unit will
turn on and off to maintain the set humidity level, less water
will be used than on manual setting.
USING THE PROGRAMMABLE TIMER
AccuSet Plus
TM
allows the user to program the humidifier to come
on at a preset time, or turn off after a set amount of time.
Setting the Off Timer:
1. Set the mode and/or humidity you wish the humidifier
to run in.
2. While the humidifier is running, press and hold the up
and down buttons simultaneously for 2 seconds. The
display will flash “00”.
3. By pressing the up and down buttons, program the humidifier
to turn off up to 16 hours later in increments of 1 hour.
4. After setting the timer, the display will return to show the
current room humidity. The timer light will illuminate to
show that the timer is activated.
5. After the predetermined length of time has passed, the
humidifier will automatically shut off.
Setting the On Timer:
1. While the humidifier is off, press and hold the up and
down buttons simultaneously for 2 seconds.
2. By pressing the up and down buttons, program the humidifier
to turn on up to 16 hours in advance in increments of 1 hour.
3. After the preset length of time has passed, the
humidifier will automatically turn on Auto Mode HI at
45% for a preset time of 2 hours.
REMOVING PERMANENT FILTER FOR
CLEANING
Through normal use, waterborne minerals and sediment
become trapped in the wick filter. The harder your water, the
greater the amount of minerals in the water, and the more
often you will need to wash your filter.
You will be able to monitor the life
of the filter in your humidifier by
checking the FilterClean
TM
Indicator.
When the unit is off, the
FilterClean
TM
Indicator will read in
the OFF position. After 60 minutes
of use, FilterClean
TM
Indicator
(refer to Figure 2 for close-up of indicator) will move from the
OFF position and indicate your filter condition. A brand new filter
will register in the blue section reading GOOD filter. After
frequent use of your humidifier, the FilterClean
TM
Indicator will let
you know when the filter needs to be washed.
When the needle is in the red (Wash Filter) section, this means the
proper amount of moisture is not getting into your air due to the
excessive minerals and sediment that have become trapped on your
filter. At this point, you should wash your filter. It is important to
wash your filter as indicated to obtain stated performance level.
To remove filter for cleaning follow the steps below:
1. Turn the unit off and disconnect from the electrical outlet.
2. Remove the tank and main housing to access the base tray.
3. Remove the filter and follow the filter and weekly
cleaning procedure.
4. Insert the refreshed filter.
5. Repeat Operating Instructions.
It will take about 30 minutes for the humidifier to reach
maximum output.
You can purchase replacement filters (model HWF65P) at your
local retailer, by calling 1-800-546-5637, filling out the accessory
card, or by visiting www.holmesproducts.com. It is recommended
that a replacement filter is purchased for uninterrupted use.
CLEANING AND MAINTENANCE
INSTRUCTIONS
Humidifiers provide comfort by adding moisture to dry, heated
indoor air. To benefit most from the humidifier and avoid
product misuse, follow all instructions carefully. Please note that
this is an electrical appliance and requires attention when in use.
In addition, if you do not follow the recommended care and
maintenance guidelines, micro-organisms may be able to grow
in the water within the water tank. You must routinely follow
the cleaning procedures that follow in order to ensure proper,
efficient operation of your humidifier. Proper maintenance and
cleaning is essential to the continued performance of your unit
and the avoidance of algae or bacteria build-up.
FILTER WASHING PROCEDURE:
1. The water tray should be cleaned when you clean the
filter. The water tray is a convenient way to carry the
filter to prevent dripping.
2. Mix 1 gallon warm tap water with 1 teaspoon
concentrated antibacterial liquid dish washing soap.
3. Fully submerge filter in soap solution for 15-20 minutes.
4. Dunk filter in soap solution several times then gently
press to release the soapy water. Be sure not to wring,
pull or scrub filter as this will degrade the filter.
5. Run under cool tap water until there is no soap
remaining. Some discoloration may still be visible, this is
normal and does not affect performance.
6. Gently shake or press the filter to remove excess water.
7. The filter can be put directly into the humidifier while
still damp if it is to be used right away, or allow filter to
dry completely if humidifier is to be stored.
Should your filter become damaged or lost, please call the
customer service number listed in the manual for a replacement
part. The part number for this HWF65P filter is: 7400001000425.
Daily Maintenance:
1. Be sure the unit is OFF and is disconnected from the
electrical outlet.
2. Remove the housing and the tank from the humidifier
and place in sink or tub.
3. Carry the base of the unit to the sink, remove the wick,
place in sink, drain any remaining water and rinse
thoroughly to remove any sediment or dirt. Wipe clean,
and dry with a clean cloth or paper towel.
4. Drain the water from the tank into the sink and rinse
tank thoroughly. Wipe clean, and dry with a clean cloth
or paper towel.
5. Put filter back in, replace the housing, then refill tank
with cool tap water as instructed earlier in the Filling
Instructions. Do not overfill.
6. Follow Operating Instructions.
Weekly Maintenance:
To Remove Scale:
1. Repeat steps 1-4 above.
2. Clean the base by partially filling the base with one 8-oz
cups of undiluted white vinegar, or by using CleanseClean
TM
(Model S1710) by the manufacturer. Leave this solution in
the base for 20 minutes, while cleaning all the interior
surfaces with a soft brush. Remove base scale by wiping the
base with a cloth dampened with undiluted white vinegar.
3. Rinse with clean warm water to remove the cleaning
solution before disinfecting the tank.
To Disinfect Humidifier Base and Tank:
1. Fill humidifier tank 1/2 full with water and 1/2
tablespoon of chlorine bleach.
2. Let the solution stand for 20 minutes, swishing every few
minutes. Wet all surfaces.
3. Carefully empty the tank after 20 minutes, and rinse
with warm water until you cannot detect any bleach
smell. Dry with a clean cloth or paper towel.
4. Place filter back into tank an refill the water tank as
directed in Operating Instructions, and turn the unit on.
21. Never place housing under water flow or immerse in liquids.
22. Do not plug in the cord with wet hands: electric shock
could result.
23. Do not pour water in any openings other than the water
tank.
24. To prevent damage to surfaces, do not place humidifier
under overhanging surfaces.
25. NEVER operate unit without water in the tank.
26. Do not move unit after it has been used until unit cools
completely.
27. Use both hands when carrying full tank of water.
PLEASE READ AND SAVE
THESE IMPORTANT SAFETY
INSTRUCTIONS
CONSUMER SAFETY INFORMATION
NOTE:
This is an electrical appliance and requires attention
when in use.
NOTE:
If moisture forms on the walls or windows of the
room, turn off the humidifier. The room already has plenty of
humidity and additional moisture may cause damage.
NOTE:
DO NOT block air inlet or outlet.
CORD AND PLUG INSTALLATION SAFETY INSTRUCTIONS
The length of cord used on this appliance was selected to reduce
the hazards of becoming tangled in, or tripping over a longer
cord. If a longer cord is necessary an approved extension cord
may be used. The electrical rating of the extension cord must be
equal to or greater than the rating of the humidifier. Care must
be taken to arrange the extension cord so that it will not drape
over the countertop or tabletop where it can be pulled on by
children or accidentally tripped over.
HOW COOL MIST WORKS
Your Holmes
®
Cool Mist humidifier draws dry air through the
rear air intake grill area. This air is then passed through a
moisture–laden wick filter, which retains the minerals and
deposits in the water. The resulting moist air is directed back
into the room from the top air grill.
NOTE:
This humidification system provides a cool, invisible
moisture output. It is normal not to see the mist.
NOTE:
A humidity level below 20% can be unhealthy and
uncomfortable. The recommended humidity level is between
40%-50%.
PRE-OPERATING INSTRUCTIONS
1. Be sure the humidifier is switched to OFF and the unit is
disconnected from the electrical outlet.
2. Select a location for your humidifier, on a flat surface,
about 4” away from the wall. DO NOT place the
humidifier on a finished floor or near furniture, which
can be damaged by moisture or water. Place on a
moisture-resistant surface.
FILLING THE WATER TANK
1. Remove the tank from the base of the humidifier and
bring to the faucet. Turn the tank upside down and twist
off the tank cap by turning counter clockwise. Fill tank
with cool, fresh tap water. DO NOT fill with warm water as
this may cause leaking. Replace the cap on tank FIRMLY.
2. When full, carry tank to the humidifier and place onto
the base. The tank holds 2.25 gallons of water and the
base holds 1/4 gallons of water. The tank will
immediately begin to empty into base.
3. Plug the power cord into a 120V AC electrical outlet.
OPERATING INSTRUCTIONS
Your humidifier is equipped with a technologically advanced
AccuSet Plus
TM
digital Humidistat. You can set the humidifier to
run continuously in manual mode or set the AccuSet Plus
TM
digital Humidistat to your desired humidity setting. The AccuSet
Plus
TM
digital Humidistat will automatically turn the humidifier
ON or OFF, depending on the preset comfort level. The comfort
level ranges between 35% and 65% relative humidity.
Manual Mode Instructions:
1. Plug the humidifier into a 120V AC electrical outlet.
2. The display will show the current room humidity.
3. To start the unit, push the MODE/OFF (
) button once
for the HIGH (3) manual setting.
4. Press the button again for the MEDIUM (2) manual setting
and again for LOW (1). After the selection is made, the
display will return to show the current room humidity.
5. To stop the unit, press and hold the button for two
seconds, or keep pressing the button until the display
reads OFF (OF).
P L E A S E R E A D A N D S AV E T H E S E
I M P O R TA N T S A F E T Y I N S T R U C T I O N S
F E AT U R E S - O P E R AT I O N S
Thank you for purchasing this Holmes
®
product. We understand
the value of quality and are committed to making superior
products that stand the test of time. We trust this product will
exceed your expectations of quality and reliability. We hope
that you enjoy this product and will consider purchasing
another Holmes
®
product in the future. To see our full product
line or if you have any questions or comments about this
product, please visit our website at: www.holmesproducts.com.
When using electrical appliances, basic safety precautions
should always be followed to reduce the risk of fire, electric
shock, and injury to persons, including the following:
1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance directly
into a 120V AC electrical outlet.
3. Keep the cord out of heavy traffic areas. To avoid fire
hazard, NEVER put the cord under rugs or near heat
registers.
4. DO NOT place humidifier near heat sources such as
stoves, radiators, and heaters. DO locate your humidifier
on an inside wall near an electrical outlet. The humidifier
should be at least 4” away from the wall for best results.
5. NEVER place humidifier in an area where it is accessible to
children. NEVER use humidifier in a closed room, particularly
where a child may be sleeping, resting, or playing (a closed
room may result in excessive humidity).
6.
WARNING:
Do not attempt to refill humidifier without
first unplugging the unit from its electrical outlet. Failure to
heed this warning may cause personal injury. Be sure to
unplug the unit by pulling on the plug and not the cord.
7. Never place anything over moisture outlet when the unit
is running.
8. NEVER drop or insert any object into any openings.
9. DO NOT operate any appliance with a damaged cord or
plug, after the appliance malfunctions, or if it has been
dropped or damaged in any manner. Return appliance
to manufacturer for examination, electrical or
mechanical adjustment, or repair.
10. Use appliance only for intended household use as described
in this manual. Any other use not recommended by the
manufacturer may cause fire, electric shock, or injury to
persons. The use of attachments not recommended or sold
by the manufacturer may cause hazards.
11. DO NOT use outdoors.
12. Always place humidifier on a firm, flat, level surface. A
waterproof mat or pad is recommended for use under
the humidifier. NEVER place it on a rug or carpet, or on
a finished floor that may be damaged by exposure to
water or moisture.
13. DO NOT allow the Moisture Outlet to directly face the wall.
Moisture could cause damage, particularly to wall paper.
14. Humidifier should be unplugged when not in use.
15. NEVER tilt, move, or attempt to empty unit while it is
operating. Shut off and unplug before removing the
water tank and moving the unit.
16. This humidifier requires daily and weekly maintenance
to operate appropriately. Refer to daily and weekly
cleaning procedures. Use only cleaners and additives
recommended by the manufacturer.
17. NEVER use detergents, gasoline, glass cleaner, furniture
polish, paint thinner, or other household solvents to
clean any part of the humidifier.
18. Excessive humidity in a room can cause water
condensation on windows and some furniture. If this
happens, turn the humidifier OFF.
19. Do not use humidifier in an area where humidity level is
in excess of 50%. Use a hygrometer, available at your
local retailer or through the manufacturer, to measure
the humidity.
20. DO NOT attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so will void
your warranty. The inside of the unit contains no user
serviceable parts. All servicing should be performed by
qualified personnel only.
F E AT U R E S - O P E R AT I O N S
C L E A N I N G / M A I N T E N A N C E
S T O R A G E I N S T R U C T I O N S
THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the
other). To reduce the risk of electric shock, this plug is intended to fit in a
polarized outlet only one way. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician to
install the proper outlet.
DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS
SAFETY FEATURE IN ANY WAY.
Figure 1
A. Water Tank
B. Carry Handle
C. FilterClean
TM
Monitor
D. Humidifier Housing
E. Control Panel
F. Humidifier Base
D
B
A
E
F
C
Figure 2
HM1865P-U_07EM1 P.qxd 4/25/07 10:35 Page 2