HL-140 E12 / HL-160 E12 / HL-190 E12 / HL-220 E12
N-120EL12 / N-140EL12 / N-165EL12 / N-195EL12
Rev. F
Page 21
8/2/18
2.7.1
Emergency stop button
The emergency stop button can be used to deactivate all scissor lift functions.
All of the functions are deactivated when the emergency stop button is pressed.
If the emergency stop button is pulled out and rotated a quarter turn clockwise, all the
functions will be activated again after two seconds.
Emergency stop button
2.7.2
Dead man's switch
The dead man's switch prevents unintentional activation of the scissor lift. After this button is
pressed, the control handle is activated.
2.7.3
Safety prop
The safety prop prevents people from becoming trapped in the scissor mechanism when work must
be carried out on it.
2.7.4
Protective guardrail
The protective guardrail prevents people from coming into contact with the moving parts of the
scissor mechanism.
2.7.5
Visual driving alarm/descent protection
The visual driving alarm/descent protection is activated when the scissor lift is being driven or is
descending. Two lights flash during operation.
2.7.6
Pipe/hose rupture safety device
An electrically controlled valve is fitted on the lift cylinder. It is only possible to lower the platform with
a control signal from the control box, even in the event of a line/hose rupture.
The maximum descent speed is limited by an orifice (constriction) in the cylinder.
Comment
Only for scissor lifts with the ‘visual driving alarm’ option.
EM
ER
GE
N
C
Y
E
M
ER
GENCY
E
M
ER
G
EN
CY