Hokuto Electronic FLASH2 User Manual Download Page 6

HOKUTO DENSHI

 

CO;LTD;

 

  FLASH2     

株式会社

 

 

 

 

 

FLASH2 Power Operations   

– Important – 

UserVcc LED indicates the status of FLASH2 power on/off. Both 2 dry alkaline 
cells and AC adapter can be used as a power supply for the FLASH2 itself. And 

also FLASH2 needs UserVcc from the connected target board. UserVcc LED can 
light when the both power supply are enough to operate. 

 

The Order of Power Supply 

We recommend the procedure below to avoid troubles. 

Power

 

ON:    FLASH2 body first, then the target board. -

 

   
 
 
 
 
 
 

Power

 

OFF:    The target board

 

first, then FLASH2 body 

 
 
 
 
 
 
 
 

 

Connectors & Cables 

Please refer to the 

“User’s Guide” about the connectors and the signal-names. 

 

 

How to Purchase the Upgrading Control Software 

Only  upgrading  the  control  software, 

FLASH2

  can  adapt  to  every  new  MCU  of  Flash  memory  MCU 

Microcomputers. For the series of single power supply, we present the new version for all Flash memory MCU 
Microcomputers releasing one after another.

 

In using R8C

M16C series MCU, firmware in the  programmer 

must be updated. (Charged.    For further information, see the end of a book.) 

If you need your control software to upgrade, please feel free to ask by E-mail.   

URL

:http://www.hokutodenshi.co.jp (Japanese site only)   

E-mail

[email protected]

 

1. 

FLASH2 Power Supply 

2. 

Target Board Power Supply

 

1. 

Power In 

2.

 

Power In 

PC 

F2WinV2 

Target Board 

FLASH2 

2. 

Power OFF 

1. 

Power OFF 

PC 

F2WinV2 

Target Board 

FLASH2 

1. 

Target Board Power Off 

2. 

FLASH2 Power Off

 

Summary of Contents for FLASH2

Page 1: ...Procedure 7 Operation Flow 7 Control Software Open 7 Parameters 8 File Loading 9 Execute programming 10 Ending Control Software Operation 10 Programming Expanded Memory of ROM less MCU 10 About progr...

Page 2: ...bed in this manual by HokutoDenshi Co Ltd and guarantees that the FLASH2 has been produced correctly and is free of any defects per the products specification The FLASH2 is guaranteed for 1 year after...

Page 3: ...rogrammer FLASH2 Target cable adaptor This AC adaptor is restricted only for Japanese domestic use For direct shipping abroad AC adapter is taken off for safety Instruction manual how to use and Infor...

Page 4: ...h drycells we recommend to exchange the drycells in every 1 hour for successively programming Programming Voltage 5V or 3 3V depend on VIN that is target Vcc power supply to Interface 18 20pin PC avai...

Page 5: ...eries contain flexible insulating label to it When placing that kind of batteries into the battery holder negative terminal of the battery holder could come into contact with positive terminal inside...

Page 6: ...d the signal names How to Purchase the Upgrading Control Software Only upgrading the control software FLASH2 can adapt to every new MCU of Flash memory MCU Microcomputers For the series of single powe...

Page 7: ...dance to install the MDAC before redo from 1 3 In the next dialogue select install folder confirm the folder where this F2WinV2 install to If it is necessary to change the default directory click the...

Page 8: ...ge confirmation is appeared automatically Select from English and Japanese The selected language can be changed to click the Other in the Set menu Power On To start the operation FLASH2 power status m...

Page 9: ...d clock we recommend the serial communication error rate below 0 16 See the bit rate register descriptions in the MCU hardware manual of the chapter about Serial Communications The communication betwe...

Page 10: ...ters are saved when the control software are closed File Loading Open Close To load the file for programming select Open from the pull down menu in File The MOT HEX file must be named MOT HEX as its e...

Page 11: ...the flash memory put 0 into here Base Address 4h 7h Bottom of the flash memory put the last address into here Base Address 8h Fh Version of the programming control program Base Address 10h write_init...

Page 12: ...be appropriately selected 4 Select the port status According to the connections of the interface select the buttons in the port status window to control the target boot mode 5 Check the option flags I...

Page 13: ...M R8C LA3A LA5A LA6A LA8A R8C LAPS R8C M11A M12A M13B M16C 26 26A 28 29 1N M16C 30P 57 5M 5L M16C 62P 62A 62N 62M M16C 63 64 64A 65 M32C 83 84 85 86 87 R32C 116 118 120 121 R32C 152 153 156 R8C 10 13...

Page 14: ...scillator of R8C group The following items of MCU group cannot be written by an on chip oscillator R8C10 R8C11 R8C12 R8C13 R8C18 R8C19 R8C1A R8C1B R8C20 R8C21 R8C22 R8C23 R8C24 R8C25 R8C26 R8C27 R8C28...

Page 15: ...the version 2 1 1 0 Please do the designation of the file referring to the following example path C Program Files x86 FLASH2 F2WinV2 exe o1 XXXX o2 YYYY o3 ZZZZ e The definition of F2WinV2 User Mat o1...

Page 16: ...ect processing with other appreciations Especially the conflict at the transmission processing will be brought the communication errors Communication error will be also occurred when more than one FLA...

Page 17: ...ress As acceptable transmission error ratio in serial communications less than 0 16 is recommended If transmission is successes on border at first error can be occurred in progress Unsoldered MCU pins...

Page 18: ...ns to MCU ports that specified in Renesas Electronics hardware manual for the concerned MCU In the reference circuit diagrams in our the User s Guide we inform the connections including this function...

Page 19: ...are to upgrade please refer our URL and send E mail to our company Our homepages helps you to confirm the adapted MCU types in the newest version URL http www hokutodenshi co jp E mail support hokutod...

Reviews: