CTC-CEN Service Manual 07-13 Rev.E
17
Select the multimeter in Ohm and check if there is continuity between all terminals of the motor. If there
continuity the motor must be replaced.
TO REPLACE THE CENTERPOST MOTOR:
Remove the two bolts in the bottom to get the motor assembly free.
Remove the pulley set screws.
Remove the pulley by using an extractor tool.
Remove the motor from its support.
Take the new motor.
Install the pulley by using rubber hammer.
NOTE:
The mounting of the new pulley must be done very carefully in
order to avoid motor bearings damaging.
Install the motor on its support.
Install the motor assy on the machine and lock it firmly.
Mount the belt.
Adjust the belt tension
Connect the wires
FIRMLY
to motor terminals following the
voltage at which the machine is supplied.
NOTE: Before connecting the wires ends, tighten all terminals
nuts.
Plug the machine to the wall.
Turn the machine on.
MACHINE UNDER TENSION DANGER
OF ELECTRIC SHOCK
Check the rotation way of the motor: If it is wrong reverse only two centerpost motor wires.
Turn the machine off and unplug it from the wall.
Mount the motor terminals cover.
IMPORTANT: WHEN REMOUNTING THE MOTOR TERMINALS COVER BE CAREFUL NOT TO CRUSH
WIRES.
Mount all protections and covers.
Turn the machine on again and check if it works fine again.
5.5 LOWER BEAD BREAKER ARM ACTUATOR M1 EAA0377G02A: CHECK AND
REPLACEMENT
:
1,5h
:
End keys 13, medium cross screwdriver, 4 and 5mm allen key, multimeter.
:
Defective actuator motor may cause the following malfunction:
1. The lower bead breaker arm does not move forward and backward.
TO CHECK THE MOTOR:
Before working on the actuator, make sure that the bead breaker arm is unlocked, cleaned and without any
scratching.
Disconnect machine from power supply.
Open the electric box.
Disconnect the actuator plug from the connector X3 of the CPU board.
Turn the machine on.
MACHINE UNDER TENSION DANGER OF ELECTRIC SHOCK
Summary of Contents for ATC 900
Page 2: ...CTC CEN Service Manual 07 13 Rev E 2 B L A N K P A G E ...
Page 7: ...CTC CEN Service Manual 07 13 Rev E 7 ELECTRIC DIAGRAM ...
Page 8: ...CTC CEN Service Manual 07 13 Rev E 8 PNEUMATIC DIAGRAMS ...
Page 117: ...CTC CEN Service Manual 07 13 Rev E 117 300KPa 25KPa 400KPa 25KPa ...
Page 119: ...CTC CEN Service Manual 07 13 Rev E 119 B L A N K P A G E ...