30
PROBLEMA RILEVATO
ORIGIN
MAINTENANCE
INTERVENTION
The mounting head does not rise up (2
mm)
CAUTION!
Before starting any maintenance in-
tervention, disconnect the pneumatic
supply, run down the air into the cylin-
ders through the controls. After the
maintenance intervention, reconnect
the pneumatic supply
1
.Pneumatic supply pressure is low;
2
.Tool support arm adjusting screw is
too tightened;
3
.Pole locking valve is defecting;
4
.Pole locking cylinder is defecting;
5
.Pole locking valve hose is Tool
support arm adjusting bended
;
1
.Check the pneumatic supply
pressure min is 8 bar;
2
.Adjust the screw too tightened;
3
.Change the locking valve
defecting;
4
.Check the cylinder and maybe
replace;
5
.Check and/or replace the ben
-
ded hoses;
PROBLEM
ORIGIN
MAINTENANCE
INTERVENTION
Problem on the inflating system
CAUTION!
Before starting any maintenance in-
tervention, disconnect the pneumatic
supply, run down the air into the cylin-
ders through the controls. After the
maintenance intervention, reconnect
the pneumatic supply
1
.Pneumatic supply pressure is low;
2
.Inflating valve silencers are stop
-
ped;
3
.The regulating filter has not been
adjusted correctly;
4
.Pedal release spring is broken;
5
.Foot control air distributor is un-
screwed;
6
.The machine is not lubricated
properly;
7
.The relief valve is defective;
8
.The inflating hose is bended
9
.Manometer is broken/put out of
tune;
10
.Inflating device is broken.
1
.Check the minimum pneumatic
supply pressure is 8 bar;
2
.Clean or replace the valve
silencers;
3
.Adjust the regulating filter pres
-
sure on max . 10 bar;
4
.Replace the pedal release
spring;
5
.Tighten the inflating valve
screws on distributor;
6
.Fill up oil in the lubrication
group;
7
.Replace the relief valve;
8
.Replace the inflating hose;
9
.Replace manometer;
10
.Replace the inflating device
PROBLEM
ORIGIN
I
MAINTENANCE
INTERVENTION
The horizontal arm slides with difficult
CAUTION!
Before starting any maintenance in-
tervention, disconnect the pneumatic
supply, run down the air into the cylin-
ders through the controls. After the
maintenance intervention, reconnect
the pneumatic supply
1
. The machine is not lubricated
properly ;
2
. The horizontal arm locking cylinder
has not been adjusted correctly;
3
. Pole sliding plate has not been
adjusted correctly;
4
. Pole locking handle is defective;
5
. The locking pole release spring is
broken;
6
. Pole Locking plate release spring
has not been adjusted correctly;
7. Adjustment-screws are unscrewed
1
. Lubricate/grease the horizon-
tal arm;
2
. Adjust the rod of horizontal
arm locking cylinder;
3
. Adjust the pole sliding plate;
4
. Replace pole locking handle;
5
. Replace locking pole release
spring;
6
. Adjust the pole Locking plate
release spring;
7. Properly tighten the
adjustment-screws
32