background image

HOBO

®

 U30 Remote Communication

Quick Start Guide

Follow the steps in this Quick Start Guide to configure a HOBO U30

Station with Remote Communication.

U30/GSM, U30/Wi-Fi, U30/Ethernet

Step 2

 - 

Register the HOBO U30 Station

Click the 

Register a Device

 link and follow the instructions on the screen. Give the

device a nickname, then enter both the serial number (SN) and Device Key (located on
a label inside the HOBO U30 Station). Click the name of the device to go to the 

Device

window and configure the device.

Step 1

 - 

Setup HOBOlink Account

If you have not already done so, set up a HOBOlink™ account. Go to
https://www.hobolink.com and follow the instructions to create and activate a user
account.

Step 3 -

Change Time Zone (if necessary)

Click 

Device Configuration

 in the Task Bar.

Step 4 -

Configure the Logging Interval

Step 5 -

Configure the Connection Interval

Initial HOBOlink Setup

Part# MAN-U30-RC   Document # 12268-D

NOTE

: This guide does not cover the following: configuration of the Analog Sensor

Port or TRMS modules, configuring a static IP address.

For more information, see the 

HOBO U30 Station/Remote Communication User

Guide

 available as a printable file at www.onsetcomp.com/rms-outdoor (under

Documentation). Note: This guide is the same for cellular, Wi-Fi, and Ethernet models.

For more information on HOBOlink, see the HOBOlink Help available

in the HOBOlink application at hobolink.com.

a. Click 

Launch Configuration

.

b. Enter a 

Launch Description

. This will also be used as the filename for data readouts.

c. Select a 

Logging Interval

. For an initial test, configure a fast logging interval.

b. Enter a 

Connection Interval 

(how frequently the HOBO U30 Station will

connect to HOBOlink). For an initial test, configure a fast 

Connection Interval.

a. Click 

Readout Configuration

.

NOTE

: For the U30/GSM, the Connection Interval is limited by the Fastest Connection

Allowed by your Communication Plan. For testing, you can bypass your GSM
Communication Plan restrictions by manually connecting to HOBOlink using
HOBOware (direct connection using a USB cable). From the main menu select

Status

, and then click the 

Contact HOBOlink

 button.

Page 1

Step 4 -

Connect the Battery

Power up the HOBO U30 Station by plugging in the built-in battery cable into the
battery connector.

Initial Hardware Setup

Step 2 -

Plug in Smart Sensors

Insert the Smart Sensor cables through the cable access opening in the bottom of
HOBO U30 Station and plug them into the Smart Sensor jacks.

Step 1 -

Install Mounting Plates

Screw the mounting plates onto the back of the HOBO U30 Station case using a
Phillips-head screwdriver. Be careful to orient the plates so that the screw heads are
sunk into the screw holes.

Step 3 

Connect the U30 to a Computer (Optional)

If you need to configure Network Setup for a U30/Wi-Fi or U30/Ethernet, or you
are using the Analog Sensor Port, you must connect the U30 to a computer
before you connect the battery. Use the USB cable supplied by Onset.

U30/GSM - go to 

Final HOBOlink Setup and Test

.

U30/Wi-Fi - go to 

Configuring WLAN Settings for the U30/Wi-Fi.

U30/Ethernet - if you have a static IP address, see 

Configuring a Static IP Address

in the U30/RC User Guide. 

Otherwise go to

 Final HOBOlink Setup and Test 

in this

Quick Start Guide

.

IMPORTANT: 

Always plug in the battery first, before you plug in any solar panel or

power supply connector. When disconnecting power, always unplug any solar panel
or power supply connector first, then unplug the battery.

IMPORTANT: 

Your Communication Plan will be activated one week after the unit is

shipped and you will begin paying for HOBOlink access, regardless of whether or not
you have registered and activated your unit.

Step 5 - 

Configure Analog Sensor Port or TRMS Module (Optional)

See the 

HOBOware User Guide

 for details.

Next Task

If you are using the Smart Sensor Expander Board, you should install cables in
those slots first. You must first remove the Secondary Cable Slot cover. See the

U30 Station/Remote Communication User Guide

 for details.

Page 2

Reviews: