4 Description
Operating manual mzr-7240
12
Technical data subject to change without prior notice!
Last update: March 2019
The resistance of the construction materials to the delivered liquids should be
verified by the operator for each individual application. Pumps handling non-
lubricating liquids have shorter service lives.
4.4
Fluidic connectors of mzr-7240
Fluidic connectors
Construction mzr-7241
Construction mzr-7245
S
lateral 1/8" NPT internal
thread
M4
Tubes, square, screw
M5
Tubes, round, bearing bracket -
table 6
Fluidic connectors
The micro annular gear pump head has an inscription on the front side. The
liquid inlet connection is marked with the letter »S«, the liquid outlet
connection with the letter »D«. An arrow indicates the inherent turning
direction of the shaft.
In order to prevent foreign bodies from penetrating into the pump, the liquid
inlet and outlet are protected with plastic plugs or screws. Please remove them
before you assembly the pump.