Mobile Foam Unit
Version 50-150
25 of 36
Error
Possible cause(s)
Remedial action
Rhythmic fluctuations of
pressure, noticeable
pulsing of the jet gun
a) Too less or too much
pressure in pulsation
damper
b) System draws false air
c) Water filter is dirty
a) Check pressure at the
pump (12), adjust if needed
b) Check all connections of
the suction lines for leaks
c) Clean Water filter (see
page
24
, section
8.1
)
No foam, despite
opened mixer
d) Foam agent tank is empty
e) Mixing set too low
d) Refill foam agent
e) Raise setting at control
panel
Red indicator lights up
during operation
a) Water tank is empty
b) Plug of tank sensor is not
plugged in fully
a) Refill water tank
b) Plug in and lock the
connector fully
10
Further troubleshooting
10.1
Engine fault (Briggs & Stratton Vanguard)
In the event of overheating or low oil level, the engine
switches off automatically. In such case ensure sufficient
supply of fresh air or respectively refill engine oil.
Most further engine problems like poor starting, rough
idling, misfires, etc. are related to the fuel and ignition
system or the air intake with its filter.
Please refer to the engine manual to localize and
eliminate such a problem within the limits of your
possibilities. Otherwise, contact the nearest Briggs &
Stratton service center.
10.2
Pressure system
Error
Possible cause(s)
Remedial action
Low working pressure
(see also next chapter
10.3
)
a) Leak in the high
pressure system
b) Relief valve setting
incorrect
c) Solenoid valves are
stucked
a) Check all pressure tubes and
hoses. Tighten or replace if
necessary
b) Adjust safety valve (see section
10.3
below)
c) Dismantle and clean valves
Air bubbles in the feed
line
a) The system draws false
air
a) Check suction hose from tank,
replace seals if necessary