21
6. Free stop control
7: External STOP signal input (STOP)
8: External reset signal input (RST)
9: External fault normally open (NO) input
10: Frequency increment command (UP)
11: frequency decrement command (DOWN)
13: Multi-speed selection S1
14: Multistage speed selection S2
15: Multistage speed selection S3
16: Run command channel is forced to terminal
17: Run command channel is forced to communication
18: DC braking Command when stop
19: The frequency command is switched to AI
20: The frequency command is switched to digital frequency 1
21: The frequency command is switched to digital frequency 2
22: Reserved
23: Counter clear signal
24: Counter trigger signal
25: Timer reset signal
26: Timing trigger Signal
27: Select the acceleration and deceleration time group
28: Pendulum frequency pause (stop at current frequency)
29: Pendulum frequency reset (return to center frequency)
30: external stop/reset signal input (STOP/RST)
02.14
Input terminal DI2
function
0
~
30
4
×
02.15
Input terminal DI3
function
0
~
30
0
×
02.16
Input terminal DI4
function
0
~
30
0
×
02.17
Input terminal DI5
function
0
~
30
0
×
02.18
FWD/REV terminal
control mode
0: Two-wire control mode 1
1: Two-wire control mode 2
2: Three-wire control mode 1
3: Three-wire control mode 2
4: Three-wire control mode 3
5: Reserved
0
~
5
0
×
02.19
Selection of terminal
function detection
when power on
0: invalid terminal operation command at power-on
1: valid terminal operation command at power-on.
0
~
1
0
×
02.20
R output setting
0: Reserved
1: Inverter is ready to run
2: Inverter in running
3. Inverter in zero speed running
4: External fault stop
5: Frequency inverter fault
6. Frequency/speed arrival signal (FAR)
7: Frequency/Speed Level Detection Signal (FDT)
8: The output frequency reaches the upper limit
9: Output frequency reaches lower limit
10: Inverter overload pre-alarm
11: Timer overflow signal
12: counter detection signal
13: counter reset signal
14: Auxiliary motor
15: Forward
16: Reverse
17: Output when the frequency arrival to the speed detection level
0
~
17
5
○
02.21
Y Open collector
output
0
~
17
0
○
02.22
R close delay
Delay from state change of relay
0.0
~
255.0s
0.0s
×
02.23
R open delay
02.24
Frequency reaches
FAR detection
amplitude
When the output frequency is within the positive and negative
detection width of the set frequency, the terminal outputs an effective
signal (low level).
0.0Hz
~
15.0Hz
5.0Hz
○
02.25
FDT1 level setting
value
0.0Hz
~
~
upper
limit frequency
10.0Hz
○
02.26
FDT lag value
0.0
~
30.0Hz
1.0Hz
○