13 (28)
6.2.2
Adjusting the General Settings
[General]
The
TemplateVersion
shows the version number of the ASCII file structure, used for
compatibility check and must not be changed.
Repeater Mode
Parameter
Description
RepeaterFunctionality = no
Repeater Mode deactivated.
RepeaterFunctionality = yes
Messages are transmitted unchanged.
Entries in
FrameFormat
and
CANGatewayTable
are
ignored.
Autobaud Timeout Detection
It is possible to set a timeout for the automatic baud rate detection. When a baud rate is
detected on one bus the timeout time starts. When this time expires and no baud rate is
detected on the second bus, the detected baud rate is adopted to the second bus. Transmitting
is attempted. If an error occurs during transmission, the device is switched off.
The parameter is only relevant if automatic baud rate detection is set for at least one CAN bus.
Parameter
Description
AutoBaudAttemptTimeout = no
Default configuration, no timeout is set, device remains in
automatic baud rate detection until baud rate is detected
on both busses.
AutoBaudAttemptTimeout = <value in
seconds>
Value: maximally 600 seconds
Bus Off Recovery
Defines the behavior of the CANbridge when a CAN bus goes into
bus off
state. With a restart
CAN message buffers of both CAN busses are cleared.
Parameter
Description
CANBusOffRecovery = no
Bus stays in
bus off
, until device is switched off.
CANBusOffRecovery = <value in seconds>
Device is restarted after specified time is expired.
Value: 1 to 60 seconds
6.2.3
Adjusting the User Settings
[User]
Sets the name of the configuration, stored in device. Can be read with download tool.
Parameter
Description
ConfigAlias = <name>
Character chain of up to 31 characters
Default value:
“Re Auto Baud (No Tx)”
CANbridge User Manual
4.01.0120.20000 2.1 en-US