15 (30)
7
Connectors
Fig. 3
CANnector front connectors
7.1
Power Connector
The device is supplied with a DC voltage from 6 V to 36 V. The power supply input is protected
against overvoltage and against polarity reversal. The CANnector provides a 3-pin Phoenix
connector.
Pin Allocation
Pin
Signal
Description
1
G
Ground
2
P
Permanent power supply to provide power in standby mode
3
W
Input to switch on the device (wake up)
A ready to use power cable is available as accessory from HMS Industrial Network (see
).
To switch on the device permanently, both inputs
P
and
W
must be connected to supply voltage (see
7.1.1
Switch-on on CAN
The device can be configured to be switched on if a CAN message is received.
If Switch-on on CAN is configured, by default the device is switched on if any CAN message is
received on CAN 1 or if any CAN FD message is received on CAN 7. With the device variant
CANnector LA it is possible to configure one specific CAN message ID or CAN FD message ID that
switches on the device. For more information how to configure the Switch-on on CAN and the
specific message see user manual
IxAdmin
.
7.1.2
Self Switch-Off
If inputs
P
and
W
are connected to supply voltage, the device stays switched on permanently. If
input
P
is connected and input
W
only gets a short impulse (e.g. if the device is switched-on on
CAN, but the CAN activity is a spike only) the device switches off after 10 seconds again. With the
ACT configuration tool the device can be configured to stay switched on even if the wakeup
reason is gone. In that case the configuration that is running on the CANnector decides when to
switch off. For more information see user manual
ACT Configuration Tool
.