8 (44)
•
Use termination for RS-485 and CAN when required.
•
RS485 Common signal reference ground (SC) is the RS485_GND pin.
4.3
Cabling
When using
Easy Config Modes
, the Bolt Serial that is to be configured as a Client does not need to be
connected to the Ethernet wires. Only power and Serial wiring are used.
To make an Ethernet, Serial and power connector cable for Anybus Wireless Bolt Serial:
Fig. 3
To maintain signal integrity, low emission and high immunity to EMI, untwist the twisted pair cable as
little as possible.
1. Cut off one of the connectors on a standard Cat5e or Cat6 Ethernet cable.
2. Strip off about 40 mm (1½ inch) of the cable jacket, from the orange, orange/white, green
and green/white wires.
The shield and the other wires are not used.
3. Strip off about 7 mm (¼ inch) of the isolation on each wire.
4. Push the pin spring release next to each socket on the connector and insert the correct wire
end according to
.
5. Connect the wires from the Serial device to the connector in the same way as the Ethernet
wiring.
6. Connect the wires from the power supply to the connector in the same way as the Ethernet
wiring.
Make sure that polarity is not reversed.
4.4
Digital Input
The digital input can be used to control roaming between Bluetooth access points (NAP). For
more information, refer to the AT Reference Guide at
If voltage is applied to the digital input for more that 10 seconds the unit will be reset to
factory defaults.