background image

 

11 

 

VERTIC 2 user guide 

Version 07/2020  

M

M

A

A

I

I

N

N

T

T

E

E

N

N

A

A

N

N

C

C

E

E

 

 

B

B

O

O

O

O

K

K

 

 

 

 
HOIST REFERENCE: 

 

 

Serial number 

:  

 

 

 

Date of 1st use : 

 

 

DATE   

Number of cycles 

evaluated 

MAINTENANCE AND QUALITY CHECKING 

  

NAME & 

APPROVALS 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

Summary of Contents for VERTIC 2

Page 1: ...1 VERTIC 2 user guide Version 07 2020 2 2 150 Kg 23 5 stones ...

Page 2: ...2 VERTIC 2 user guide Version 07 2020 ...

Page 3: ...e products inside anytime TABLE OF CONTENTS 1 PREAMBLE page 3 2 DESCRIPTION page 3 6 2 1 Where to use Vertic 2 2 General description 2 3 Technical description 2 4 Dimensional characteristics 2 5 Labelling 3 VERTIC ASSEMBLING page 8 13 3 1 Package contents 3 2 Vertic assembling page 13 4 USE page 14 17 4 1 First use 4 2 Vertic use 4 3 Safety 4 4 Control box operating battery charge 4 5 Storage inst...

Page 4: ...duct This information has been carefully checked by HMS VILGO This is not an exhaustive list and HMS VILGO is not responsible for any kind of mistakes or omissions 2 DESCRIPTION 2 1 WHERE TO USE VERTIC2 The Vertic2 is a lifting and transfer device It is used to transfer disabled or elderly people At home to transfer the patient to an armchair a toilet seat or a chair In independent living structur...

Page 5: ...es Electric protection classification Class II Applied parts Type B Electrical equipment conformed to NF EN 60 601 1 and to NF EN 60 601 1 2 Duty cycle 2 min 18 min 10 Input 230V 50 HZ Actuator input 24 V CC Battery charge required time 15 hrs Battery autonomy 40 cycles Electrical equipment protection remote control IP X6 control box IPX4 actuator IP X4 Pedals Mast Control box Driving handles Arms...

Page 6: ...aximum back height 5 1 In Total lift lifting radius overall dimension 1 Lifting radius at the highest suspension point 1 6 In 2 Total lift 3 4 19 3 In 3 Minimal suspension point height 35 8 In 4 Lifting radius at lowest point 22 2 In 5 distance between floor hooks in the low position 34 2 In 6 distance between floor hooks in the high position 51 2 In 7 Overall height when in the low position 41 3 ...

Page 7: ... follow up of the medical disposal It also gives to you the security loading charge for a good use There are 4 labels One on the basis of the Vertic2 one on the electric actuator one on the control box and one on the remote control Standards By this label HMS VILGO ensures that Vertic2 hoist is conformed to European directive 89 336 referring to electromagnetic compatibility and to European direct...

Page 8: ...IC2 ASSEMBLING 3 1 PACKAGE CONTENTS Les éléments suivants composent le carton 1 Vertic 2 chassis Control box x1 Remote control x1 Main cable x1 Fixing screw CHC 6x80 x2 Anti pulling up Cable kit x1 Spanner 6 section 5 x1 1 box contening Actuator cable x1 ...

Page 9: ...Actuator arms connection Check fixing screw worn state 10 Arm hooks check the welding on all 3 hooks 11 Emergency release Check electrical and manual release operating 12 Sling Check seams 13 Leg rest check the welding point of the leg rest check the blocking device 14 pole pole support connection Check knobs presence and assembling Check support pole welding Please refer to page 10 to obtain the ...

Page 10: ...980 23725 28470 33215 37960 42705 47450 14 5110 10220 15330 20440 25550 30660 35770 40880 45990 51100 15 5475 10950 16425 21900 27375 32850 38325 43800 49275 54750 16 5840 11680 17520 23360 29200 35040 40880 46720 52560 58400 17 6205 12410 18615 24820 31025 37230 43435 49640 55845 62050 18 6570 13140 19710 26280 32850 39420 45990 52560 59130 65700 19 6935 13870 20805 27740 34675 41610 48545 55480 ...

Page 11: ...RTIC 2 user guide Version 07 2020 M MA AI IN NT TE EN NA AN NC CE E B BO OO OK K HOIST REFERENCE Serial number Date of 1st use DATE Number of cycles evaluated MAINTENANCE AND QUALITY CHECKING NAME APPROVALS ...

Page 12: ...1128 A001072 A001061 1 1 2 actuator arms connection Ø 10 Lg 64 20 articulation pole cross piece axle Ø 8 stop nut Ø 8 washer pole actuator Lifty 4 fixing plate Ø 12 stop nut HH 12x80 screw A001128 A001072 A001061 A501244 A001080 A501251 1 2 2 2 2 2 actuator pole connection Bague laiton Ø 22 10 Ø 10 Lg 56 20 articulation pole arms Ø 8 stop nut Ø 8 washer A002016 A501067 A001004 A001062 2 1 2 2 Pole...

Page 13: ...he remote control and the actuator cables and plug the shutter 2 Put the anti pulling up hood in placing the cables through the opening 3 Screw the hood to the control box with a crossed screw driver 1 2 Plug the actuator cable to the control box and to the actuator You can lock this connection with the supplied locking clip 4 Your Vertic2 is now ready to run ...

Page 14: ...bed 1 Bring the Vertic closer and place the patient s feet on the foot rest depending on the situation and layout of the space available narrow or widen the side feet to get close to the patient 2 Adjust the leg rest up or down to block the patient s shins against it pull the locking screws on each side of the pole 3 Lock brakes 4 Set up the sling 5 Press the up button on the handset to lift up th...

Page 15: ...system is not efficient 4 4 CONTROL BOX OPERATING BATTERY CHARGE If the charging level is too weak an alarm sounds in a constant way when the control box is activated The charging of the battery is then necessary The control box has its own integrated charger To charge batteries connect the control box to the 220 VAC main power line until the green led turn on indicating batteries are charged appr...

Page 16: ... condition immediately replace a sling that starts to show any tear Electrical parts Test the emergency stop switch while lifting and lowering the support beam Look at the electrical cables cover Test crushing safety system by placing an item on the support beam going down way Chassis Check the brake of the back wheels Look at the global geometry on the Vertic2 no bent item Make sure that the 4 wh...

Page 17: ...L NUMBER LABEL WILL NOT BE COVERED BY THE WARRANTY The warranty does not cover any breakdown due to inappropriate or wrong use or maintenance in spite of the specifications and use instructions stated in this manual electrical shock torn cables etc Warranty does not cover any breakdown or malfunction due to parts being swapped over or replaced with used or unapproved parts 5 4 RECYCLING Recycling ...

Page 18: ...18 VERTIC 2 user guide Version 07 2020 ...

Page 19: ...19 VERTIC 2 user guide Version 07 2020 ...

Page 20: ...eur www hms vilgo com Site de Lille Parc Eurasanté 243 Rue Allendé 59120 LOOS LEZ LILLE Tél 33 0 3 20 84 81 50 Fax 33 0 3 20 59 58 08 Site de Bergerac Rte de Sainte Alvère Creysse BP 212 24102 BERGERAC Cedex Tel 33 0 5 53 74 45 50 Fax 33 0 5 53 63 06 07 2 2 ...

Reviews: