HME NEXEO HDX RT7000 Quick Reference Installation Manual Download Page 1

Quick Reference Installation Guide

HM ELECTRONICS, INC.

2848 Whiptail Loop, Carlsbad, CA 92010  USA

Phone: 1-800-848-4468       Fax: 858-552-0172

Website: www.hme.com     Email: [email protected]

HME# PUB - 00074

Rev C  02/07/22

NEXEO | HDX™ RT7000

 

REMOTE TRANSCEIVER

The RT7000 (Fig. 1) is a transceiver used to facilitate communication 
with the NEXEO | HDX™system. It uses a wired connection to the 
base station but is wireless for headset communication. Up to four 
RT7000s can be connected to the base station for greater coverage.

TOOLS/EQUIPMENT REQUIRED 

•  Drill and drill bit set
•  Screwdriver (Phillips #2), tape measure, pencil/maker
•  Cable Pull Equipment (fish stick/tape, pull string, cable ties, etc.) 
•  Safety glasses, ladder

INSTALLATION, SETUP, AND OPERATION

1.  Survey the premises to determine a good location to mount the 

RT7000 (see "RT7000 Notes" on page 3 and Fig. 12 on page 4). 

2.  Route the Ethernet cable from the base station to the RT7000 

location. 

3.  Loosely mount the RT7000 (until range tested with the Installa-

tion Wizard in step 7.

4.  Connect the Ethernet cable to the RJ45 port on the rear of the 

RT7000 (see Fig. 2) and the other end to one of the available 
ports on the base station (see Fig. 3, Fig. 11, and Table 2). The 
base station provides power for the RT7000. The center LED on 
the front of the RT7000 is the power indicator. It turns on solid 
green once power is connected (see Fig. 9 on page 3). 

5.  One of the outer LEDs (numbered 1 to 4) also turns on and 

initially flashes a different color as the RT7000 completes a scan 
of the environment to find an available channel (see Table 1). 
Once the scan is finished, this outer LED also turns solid green 
(see Fig. 9 on page 3). During this time, the base station HOME 
screen also provides a color-coded status for the RT7000 (it is 
labeled as "Transceivers," see Fig. 4). The 

 indicator 

initially turns 

 (yellow) while scanning for a channel before 

turning  

  (green) when one is found. This can take a few 

minutes. 

Fig. 4

6.  At the base station, go to 

SYSTEM, 

log in, 

then tap the 

TROUBLE-

SHOOTING

 tab and select “Installation Wizard” from the drop-

down list. Tap the “Start Installation Wizard” button. This opens 
the Installation Wizard, as shown in Fig. 5.

Fig. 1

Rear View

Fig. 2

Fig. 3

1

2

3

4

RT7000 TRANSCEIVER

Front View

RT7000 TRANSCEIVER

Rear View

THIS SIDE UP

Mounting Holes

RJ45 Port

for Ethernet cable

NEXEO BASE STATION

 PCBA (Partial)

Remote

XCVR 1

Remote

XCVR 2

Remote

XCVR 3

Remote

XCVR 4

Ethernet/

Network

Telephone

Interface

Timer Greet

Veh Detect 1

Timer Greet

Veh Detect 2

Veh Detect

Inputs

Alert

Inputs

Remote

Switches

Early

Warnings

Power 

In

DC +

DC -

GND

Micro

USB

J200

J600

J201

J800

J801

J802

J805

J804

J803

J2003

J3000

J4500

J4501

J1400

J3200

J3400

J3600

J3800

1

1

1

1

1

1

1

1

1

1

1

Serial

Debug

USB

J?301

J?300

J1

PCBA

Side View Detail

Ethernet

(Network)

Remote

Module 1

Remote

Module 2

Remote

Module 3

Remote

Module 4

Power

Transceiver (x4)

1

2

3

4

Vertical Mount Only

(this way up)

REMOTE TRANSCEIVER

(RT7000)

Reviews: