![Hiwin RC4 Original Instruction Download Page 63](http://html1.mh-extra.com/html/hiwin/rc4/rc4_original-instruction_2140486063.webp)
C21UE102-2110
61
3.3.
Example of Connection
(1)
Digital INPUT can be an NPN or PNP, adjusted by pin 1 (FI COM) and pin 16 (DI COM), supplied by an
external power supply.
COM→24V: NPN
COM→0V: PNP
(2)
Digital OUTPUT can be an NPN or PNP, adjusted by pin 15 (FO COM) and pin 30 (DO COM), supplied by
an external power supply.
COM→0V: NPN
COM→24V: PNP
The maximum current at the single output supplied by external output is 100mA.