![Hiwin EM1 Series User Manual Download Page 40](http://html1.mh-extra.com/html/hiwin/em1-series/em1-series_user-manual_2140499040.webp)
User Manual
Installation, Assembly and Commissioning
EM1 Series AC Servo Motors
EM1-01-0-EN-2110-MA
Page
40
of
72
8
Installation, Assembly and Commissioning
8.1
General
8.1.1
Installation Environment
Operating temperature:
0
°
C to 50
°
C (From 40 to 50 de-rating avoid condensation and icing)
Operating humidity:
20 % to 80 % RH (Avoid condensation and icing)
Storage temperature:
-15
°
C to 70
°
C (Avoid condensation and icing)
Storage humidity:
20 % to 80 % RH (Avoid condensation and icing)
Vibration/Shock resistance:
Less than 49 m/s
2
(In three direction: Vertical, side to side, and
front to back)
Elevation:
Less than 1.000 meters (From 1.000 m to 2.000 m de-rating)
Installation Precautions:
1.
Please install this product indoors, out of direct sunlight.
2.
Please install this product in a site without humidity, dust or hazardous/corrosive
gases or liquids.
3.
The servo motor’s shaft is not water or oil proof. Thus, do not install or use this servo
motor in an environment with water or oil droplets, excessively high humidity or
corrosive/flammable gases.
4.
Do not store this product in a site with vibration that exceeds the quantity stated in
the specification document.
5.
The servo motor shaft material is not rust-resistant. Although grease has been
applied to prevent rust before the products shipped, if the storage time exceeds six
months, inspect the shaft every three months to make sure that it is not rusted. Apply
an appropriate amount of rust-prevention grease when needed.
8.1.2
Tools and Equipment
1. Installation
Item
Tool
Motor
Torque wrench
Oil seal
–
Key
Hand press machine
Belt
Screwdriver or wrench
Cable
–
8.1.3
Personal Protective Equipment
When in the vicinity of the AC servo motor systems, the following personal protective equipment
is required:
Safety shoes
Protective helmet
Protective gloves