TS-NX: GSM DOOR ENTRY UNIT
Installation Manual
Page 1: ...TS NX GSM DOOR ENTRY UNIT Installation Manual ...
Page 2: ... SMS COMMANDS 37 10 PRINT OUT OF THE PARAMETERS 39 10 1 RECEIVE ALL PARAMETERS PALL 39 10 2 CHECK SW REVISION PSW 39 10 3 CHECK SIGNAL QUALITY PSQ 39 10 4 RECEIVE TELEPHONE NUMBERS PTN 39 10 5 RECEIVE LINKS PLN 39 10 6 RECEIVE INPUT PARAMETERS PIN 40 10 7 RECEIVE INPUT FILTER VALUE PID 40 10 8 RECEIVE OUTPUT FILTER VALUE POD 40 10 9 RECEIVE DELAY BEFORE DIAL VALUE PDD 40 10 10 RECEIVE ACCESS TELEP...
Page 3: ...0 18 STATE OF THE OUTPUTS PORC 42 10 19 MANUAL GSM MODULE RETARD MRES 42 10 20 RECEIVE STATUS OF INPUTS INS 42 10 21 RECEIVE TS NX LOG 43 11 CHANGING PARAMETERS USING THE SMS COMMANDS 44 12 DEFAULT SETTINGS ON TS NX 46 13 PARAMETERS PRINT OUT COMMANDS 49 14 TECHNICAL SPECIFICATIONS 50 ...
Page 4: ...TS NX INSTALLATION MANUAL Page 4 Figures Figure 1 TS NX Connection diagram 12 Figure 2 Input Connection diagram 15 Figure 3 Output Connection diagram 20 ...
Page 5: ...xample 22 Table 10 Prepaid card validity parameters 24 Table 11 Credit example 24 Table 12 Set up parameters 29 Table 13 Set up parameters example 30 Table 14 Message parameters 31 Table 15 Message parameters example 32 Table 16 Intercom parameters 33 Table 17 Intercom parameters example 34 Table 18 CLIP parameters 35 Table 19 CLIP parameters example 35 Table 20 LOG parameters 36 Table 21 LOG para...
Page 6: ...ible to interference which could affect performance SWITCH OFF IN HOSPITALS Follow any restrictions Switch the unit off near medical equipment SWITCH OFF IN AIRCRAFT Follow any restrictions Wireless devices can cause interference in aircraft SWITCH OFF WHEN REFUELING Do not use the unit at a refueling point Do not use near fuel or chemicals SWITCH OFF NEAR BLASTING Follow any restrictions Do not u...
Page 7: ...com communication system that is designed to ensure low cost reliable and single box solution for intercom application It is designed for unlimited range wire free GSM intercom and CLIP support In addition TS NX supports alarm detection stay alive messages credit detection etc ...
Page 8: ... support 2 alarm inputs 2 additional on extension connector 2 outputs relay supported Up to 100 telephone numbers for CLIP support Programming by USB SIM Key editor Download programming by SMS command Anti tampering input Applications Single box wire free intercom solution Remote gate opener CLIP Simple alarm support ...
Page 9: ...when you insert the SIM Connect inputs and outputs to TS NX Connect the antenna to antenna connector Connect power cable to TS NX device Connect device to source power supply voltage Wait until LED3 display is turned ON green and LED1 blue starts flashing This is set in around 1 minute TS NX unit is now ready to operate IMPORTANT Before sending any SMS commands to TS NX device TS NX must be in nor...
Page 10: ... Red LED LED2 When LED 2 is ON the unit has a problem with a GSM network connection or the GSM part of the unit is out of order In this case immediately call the service Yellow LED LED3 Short flashing indicates that the GSM module is ON but it is not yet connected on the GSM network After connection yellow led is flashing with short pulse ON and a long pulse OFF ...
Page 11: ...a stored in the phone book memory By sending this SMS to TS NX all programmed parameters and numbers are cleared SDCLR After sending SMS you should wait at least 60 second for the command to be executed NOTE By sending this command to the TS NX all programmed data are erased from the SIM card including SMS messages After the device will start it will be configured with factory defaults ...
Page 12: ...TS NX INSTALLATION MANUAL Page 12 7 CONNECTION DIAGRAM Before connection the TS NX please take a look at connection diagram Figure 1 TS NX Connection diagram ...
Page 13: ...TS NX INSTALLATION MANUAL Page 13 ...
Page 14: ... your personal GSM phone Add programming parameters in SIM Card Phone Book You can program TS NX remotely by SMS command You can program TS NX with USB key and SIM manager You can program TS NX with direct USB connection with the use of configuration software running on PC NOTE To receive configuration software for PC please contact your local distributor ...
Page 15: ...ions needed for alarm to be trigged The second section is used to report alarm 9 1 1 ALARM TRIGGERING Parameters are used to control filter the triggering of the alarm inputs 9 1 1 1 IN parameter Alarm input can be on only used as normal open N O triggered with GND When you need the input feedback information it is possible to receive SMS when input returns from alarm to normal position To receive...
Page 16: ...operation for input 4 ID1 Input time integration delay on input 1 ID2 Input time integration delay on input 2 ID3 Input time integration delay on input 3 ID4 Input time integration delay on input 4 DD1 Time delay for alarm reporting on input 1 DD2 Time delay for alarm reporting on input 2 DD3 Time delay for alarm reporting on input 3 DD4 Time delay for alarm reporting on input 4 Table 1 IN ID and ...
Page 17: ...r reporting alarm events 9 1 2 1 TN parameter Telephone numbers for remote alarm reporting are listed as TN parameters Remote alarm reporting on TS NX is done via SMS messages 9 1 2 2 LN parameter This parameter is used to link alarm event from inputs or any other source to the telephone numbers from TN list 9 1 2 3 LOT parameter LOT parameter is used to define the time control for voice calls The...
Page 18: ...LN7 NAC list No linking TN1 TN5 see note LN8 Log status No linking TN1 TN5 LOT Time out for GSM connection Table 3 Remote alarm reporting parameters NOTE When telephone number calling or messaging TS NX is not on the CLIP list not acknowledge event occurs NAC The telephone number responsible for this event can be send to TN user for notification Example Direct programming on the SIM card TS NX PRO...
Page 19: ... activate 1 or deactivate 0 the output There is a special case when the user can select for first digit output selection number 0 In this case all outputs control by the same time Combination must be pressed in 2s interval and must be 3s apart to be valid NOTE TS NX must be in voice connection to support DTMF output control Example DTMF combination Description 00 Deactivate ALL outputs 01 Activate...
Page 20: ...vior OS 0 Disabled OS 1 Bi stable toggle mode OS xxx Mono stable pulse mode duration in seconds Typical connection for the output Figure 3 Output Connection diagram 9 2 2 OD parameter OD parameter is used to link the alarm event directly to output 9 2 3 OP1 OP2 parameters Parameters are used to invert the polarity of the outputs 0 normal 1 inverted ...
Page 21: ... parameters Example Direct programming on the SIM card TS NX PROGRAMMING TABLE SIM CARD PHONE BOOK Name Number Description OS1 1 Bistable toggle mode OS2 14 Monostable pulse mode 14s pusle OD1 1 Input 1 activates output 1 OD4 2 Input 2 activates output 2 OP1 1 Output 1 inverted Table 7 Output management parameters example Remote programming by SMS OS1 1 OS2 14 OD1 1 OD4 2 OP1 1 9 3 SECURITY LEVEL ...
Page 22: ...ameter TN1 has access to unit SL 2 Numbers stored under parameters TN1 to TN2 have access to unit SL 3 Numbers stored under parameters TN1 to TN3 have access to unit SL 4 Numbers stored under parameters TN1 to TN4 have access to unit SL 5 Numbers stored under parameters TN1 to TN5 have access to unit Table 8 SL parameter Example Direct programming on the SIM card TS NX PROGRAMMING TABLE SIM CARD P...
Page 23: ...nd time validity checking different parameters are used 9 4 1 1 LCV and SCV parameter LCV is used to set the limit for low credit event If the credit on prepaid SIM cards falls below this limit SMS is send SCV the period of valid operating time varies with different GSM network providers The value can be programmed from 1 to 360 days The default value does not presume any kind of expiry warning Fo...
Page 24: ...e in days CC1 Credit number for credit check universally used CC2 Credit number for credit check dedicated for Italian TIM mobile provider CC3 Credit number for credit check dedicated for Italian Vodafone mobile provider CREF String for parsing replay message from CC1 number CVODA String for parsing replay message from CC2 number CTIM String for parsing replay message from CC3 number Table 10 Prep...
Page 25: ...TS NX INSTALLATION MANUAL Page 25 ...
Page 26: ...r Parameter is used to synchronise TS NX clock to GSM network clock User must enter here the number of the TS NX SIM card Telephone number of TS NX device 9 5 4 RAN parameter Parameter is used to provide support for auto answer options for TS NX device The number defines the numbers of rings needed for TS NX device to answer the incoming call The incoming number must be on the TN list for TS NX de...
Page 27: ...0 this function is disabled 9 5 7 MNF parameter When it is necessary to fix the GSM network to one provider the user can use the MNF parameter The MNF parameter switches automatic network searching to manual Example MCC MNC code for Simobil is 29340 Mobitel is 29341 TIM is 22201 and Vodafone Italy is 22210 More information about national MCC MNC codes can be acquired at http www activexperts com a...
Page 28: ... device 9 5 12ADF parameter Parameter is used to define voice refresh function to prevent blocking of SIM in some networks 9 5 13LNG parameter LNG parameter switches between the preprogrammed languages 0 English 1 Italian 2 Slovenian 3 Croatian 4 Dutch 5 German 6 Spanish 9 5 14BUZ parameter Parameter is used to control buzzer functionality on TS NX Buzzer is used to audio support some events on TS...
Page 29: ...rol for automatic system restart ADF Auto dial functionality Call TN1 LNG Language selection BUZ Buzzer control Table 12 Set up parameters Example Direct programming on the SIM card TS NX PROGRAMMING TABLE SIM CARD PHONE BOOK Name Number Description HTN 0 Hidden telephone number of the TS NX device MNF 29340 Manual fixing of the GSM provider Simobil LNG 1 Switch on Italian language MIC 2 Microphon...
Page 30: ...TS NX INSTALLATION MANUAL Page 30 Table 13 Set up parameters example Remote programming by SMS HTN 0 MFN 29340 LNG 1 MIC 2 SPK 20 TST 24 BUZ 0 ESC 2 ...
Page 31: ...e message is stored in the SIM phone book so you should add any number for correct operation 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 0 U S E R L O C A T I O N 1 I N P U T 1 2 I N P U T 2 3 I N P U T 3 4 I N P U T 4 NOTE Message should not be longer than 14 characters Space is also counted as one character 9 6 1 Table of parameters Name Comment 0 User location same for all alarm messages 1 Input 1 s...
Page 32: ...rent version equipped with only 1 call button so only E GROUP is used and described in this manual 9 7 1 xTN1 to xTN5 parameters Parameters are the call numbers for intercom application 9 7 2 RTNx parameter Parameter defines the ring time time out RTNx timer is started when the call button is pressed If the RTNx timer expires before the GSM voice connection is established then TS NX device calls t...
Page 33: ...rt time for the time zone functionality 24h time format 9 7 4 2 TZEx parameter Parameter is used to configure the end time for the time zone functionality 24h time format 9 7 5 Table of parameters Name Comment ATN1 Button 1 Telephone number 1 ATN2 Button 1 Telephone number 2 ATN3 Button 1 Telephone number 3 ATN4 Button 1 Telephone number 4 ATN5 Button 1 Telephone number 5 RTNA Button 1 time out co...
Page 34: ...0 9 8 CLIP CLIP is used to provide the free of charge options to control the outputs 9 8 1 CLPEN parameter Parameter used to enable CLIP functionality 9 8 2 CLPOU parameter Parameter used to choose which output will be controlled by the CLIP functionality 9 8 3 CLPI parameter This parameter if set is a precondition for CLIP function to control the output 9 8 4 CLP1 CLP100 parameter Set of telephon...
Page 35: ...umber 100 Table 18 CLIP parameters Example Direct programming on the SIM card TS NX PROGRAMMING TABLE SIM CARD PHONE BOOK Name Number Description CLPEN 1 Enable CLIP functionality CLPOU 2 CLIP control output 2 CLPI 0 No input activation condition CLP1 040414414 CLIP number 1 CLP2 042340880 CLIP number 2 Table 19 CLIP parameters example Remote programming by SMS CLPEN 1 CLPOU 2 CLPI 0 CLP1 04041441...
Page 36: ...S NX User can select between nonvolatile memory on TS NX or select USB to transfer events directly via USB to PC LOGI 0 Logging is OFF LOGI 1 Logging in internal memory LOGI 2 Logging to USB interface 9 9 3 ALC parameter Parameter is used to control behavior when log on TS NX is full User can select between auto log clear or manual clear of log ALC 0 Automatically delete buffer when memory is FULL...
Page 37: ... auto cleared when full Table 21 LOG parameters example Remote programming by SMS LOGN 5 LOGI 0 ALC 1 9 10 SPECIAL SMS COMMANDS These commands can only be issued only over SMS message and are used to control some special functions of TS NX device 9 10 1ORC command Command is used to control outputs directly via SMS message 9 10 2SDCLR command To clear all data on SIM card SDCLR command is used 9 1...
Page 38: ...ame Comment ORC1 Control of output 1 ORC2 Control of output 2 SDCLR Delete all SIM content LCRL Delete log on TS NX device MRES Manual reset of GSM module SSRES Manual reset of TS NX device Table 22 SMS commands Example Remote programming by SMS SMS commad Description ORC1 1 Activate output 1 ORC2 0 Deactivate output 2 SDCLR Clear all data on SIM LCLR Delete log on TS NX device MRES Manual reset o...
Page 39: ...his command to TS NX you receive SMS messages with current SW version running on TS NX device PSW 10 3 CHECK SIGNAL QUALITY PSQ By sending this command to TS NX you receive SMS messages with signal quality TS NX device is connected to network PSQ 10 4 RECEIVE TELEPHONE NUMBERS PTN By sending this command to TS NX you receive SMS message with all currently programmed telephone numbers TN1 TN5 PTN 1...
Page 40: ...LUE POD By sending this command to TS NX you receive SMS message with all currently programmed direct output links OD1 OD5 POD 10 9 RECEIVE DELAY BEFORE DIAL VALUE PDD By sending this command to TS NX you receive SMS message with all currently programmed Input filters DD1 DD4 PDD 10 10 RECEIVE ACCESS TELEPHONE NUMBERS PSL By sending this command to TS NX you receive SMS message with programmed SL ...
Page 41: ...eters TST MNF PPA 10 14 RECEIVE CREDIT PARS PARAMETERS PCREF By sending this command to TS NX you receive SMS message with all currently programmed credit parse parameters CREF CVODA PCREF 10 15 RECEIVE ALL CLIP PARAMETERS PCLP By sending this command to TS NX you receive SMS message with all currently programmed CLIP functionality related parameters CLPEN CLPOU CLPI CLPx PCLP NOTE User can use PC...
Page 42: ...Credit amount on your prepaid SIM card PCCX Where X is the number of programmed prepaid card provider 10 18 STATE OF THE OUTPUTS PORC By sending this command to TS NX you receive SMS message with current outputs state PORC 10 19 MANUAL GSM MODULE RETARD MRES By sending this command to TS NX shuts down GSM module and after a few second it switches the power of the GSM module ON again The unit reboo...
Page 43: ...CEIVE TS NX LOG By sending this command to TS NX you receive SMS message with log on TS NX device PLOG NOTE User can use PLOG x y to define the number of logs to be printed x start event y end event Example PLOG 1 30 Prints first 30 log events ...
Page 44: ...e to enter telephone numbers in to TS NX you can use the following example TN1 040713470 TN2 38643364850 If you would like to receive confirmation SMS write before SMS command TN1 040713470 TN2 38643364850 Return SMS from TS NX is TN1 040713470 TN2 38643364850 NOTE You can use the same programming procedure for all parameters It is also possible to change different parameters with one SMS Consider...
Page 45: ...INSTALLATION MANUAL Page 45 Send SMS message to TS NX telephone number and in a few seconds you receive SMS message from TS NX The sentence of the SMS must be the same as the one you have sent to TS NX before ...
Page 46: ...put 1 link to tel numbers LN2 1 Input 2 link to tel numbers LN3 Empty Input 3 link to tel numbers LN4 1 Input 4 link to tel numbers LN5 Empty Periodic SMS text link to tel numbers LN6 Empty SIM card refill link to tel numbers LN7 Empty NAC link to tel numbers LN8 Empty LOG full link to tel numbers ID1 1 Input 1 delay filter on input ID2 120 Input 2 delay filter on input ID3 1 Input 3 delay filter ...
Page 47: ... out LOGI 0 Log interface ALC 1 Automatic log clear ADF 90 Auto dial functionality Call TN1 ARST 0 Automatic reset timeout CREF EUR Parse text contact support CTIM EURO Parse text contact support CVODA DISPON E Parse text contact support OP1 1 Output invert 1 OP2 1 Output invert 2 BUZ 1 Buzzer control SPO 1 SIM card starting position CLPEN 1 Enable CLIP functionality CLPOU 1 Control output pin whe...
Page 48: ...TS NX INSTALLATION MANUAL Page 48 Table 24 TS NX default settings ...
Page 49: ... DDx parameters PSL Prints SL parameter POS Prints OSx parameters P Prints x parameters PPA Prints various setup parameters PCLP Prints CLIP parameters PLOG Prints log of the TS NX PCREF Prints credit pars parameters PCN Prints credit request numbers PCC1 Prints credit for TS NX universal request PCC2 Prints credit for TS NX TIM Italy PCC3 Prints credit for TS NX VODAFONE Italy PWG Prints Wiegand ...
Page 50: ...ent consumption idle mode 40mA Quad band GSM module 850 900 1800 1900 MHz PCB dimensions 106 89 mm Unit dimensions 1 button 156 x 116 x 61 51 mm Call buttons Up to 8 in larger enclosure 290 116 56 mm External Antenna SMA 1 Weight 945 gr Alarm inputs 2 Alarm outputs relay 2 12V DC Aux Power Supply output Y max 100 mA 12 24V AC DC Power Supply input Y Anti tamper protection optional ...