Hitron HM-10 Series Instruction Manual Download Page 1

 

 

HM-12(10) Series 

 

        HITROL CO., LTD.                                                                                1 

Doc. no. : HM-12(10)_IM_Eng_Rev. 1 

Issue date : 2022. 01 

HITROL CO., LTD. 

HEAD OFFICE.FACTORY.R&D INSTITUDE 
HITROL CO., LTD. 141, Palhakgol-gil, Jori-eup 
Paju-si, Gyeonggi-do, Korea   
TEL. : (00)-82-31-950-9700 
FAX. : (00)-82-31-943-5600 
www.hitrol.com 

 
 
 
 

INSTRUCTION MANUAL 

FLOAT TYPE LEVEL SWITCH 

HM-12(10) Series 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for HM-10 Series

Page 1: ...ev 1 Issue date 2022 01 HITROL CO LTD HEAD OFFICE FACTORY R D INSTITUDE HITROL CO LTD 141 Palhakgol gil Jori eup Paju si Gyeonggi do Korea TEL 00 82 31 950 9700 FAX 00 82 31 943 5600 www hitrol com IN...

Page 2: ...tents where WARNING is marked before carrying out the work Table of Contents Overview 3 Operating Principle 3 Features 3 Specification 4 Dimension 5 Operating and Usage 8 Precautions for Installation...

Page 3: ...proof as per usage HM 12 10 Series is a level switch which uses a force of repulsion by magnetic each other As the process level rises the float rises and the holder magnet in the housing is repelled...

Page 4: ...ss Connection 50AJIS10KRF 40AJIS10KRF 65A JIS 10K RF 92 x 92 mm Material Housing AL AL SUS304 B S Wetted part SUS 316L SUS 316L B S Cable Entry PF 1 2 F Model HM 12H SP HM 12H SP Ex HM 12H L HM 12H L...

Page 5: ...HM 12 10 Series HITROL CO LTD 5 HM 10 Actual product may have a slight tolerance Dimension The dimensions on the following pages are indicated in mm HM 12S HM 12D...

Page 6: ...HM 12 10 Series HITROL CO LTD 6 HM 12H Actual product may have a slight tolerance The dimensions on the following pages are indicated in mm HM 12H Ex HM 12H SP...

Page 7: ...HM 12 10 Series HITROL CO LTD 7 HM 12H L Actual product may have a slight tolerance The dimensions on the following pages are indicated in mm HM 12H L Ex...

Page 8: ...ugh periodic inspections Therefore the user shall maintain and repair the product through periodic inspections conducted at least once a year The appearance of the product shall be visually checked to...

Page 9: ...gloves when removing it to prevent a burn Disassemble work shall be done with the power off If there is an atmosphere of explosive gas do not open the cover of the product Unlock the lock key before...

Page 10: ...0 9700 Headquarters A S F A X 031 943 5600 Headquarters A S The fluid temperature of the container where the product is used shall not exceed 100 for HM 10 120 for normal version of HM 12 Series 250 f...

Reviews: