SECTION I: USER 

 

 

 

I.5 

WARNINGS REGARDING POTENTIALLY TOXIC 
SUBSTANCES 

 

 

DANGER! 
Read the following ecological information and 
requirements about the refrigerants employed 
carefully. 

I.5.1.1 

Identification of the Type of Refrigerant 

Fluid Used 

  Difluoromethane (HFC 32) 50% by weight 

CAS No°: 000075-10-5 

  Pentafluoroethane (HFC 125) 50% by weight 

CAS No°: 000354-33-6 

I.5.1.2 

Identification of the Type of Oil Used 

The lubricant used in the unit is polyester oil; please refer to the 
indications on the compressor data plate. 

 

 

 

DANGER! 
For further information regarding the 
characteristics of the refrigerant and oil used, refer 
to the safety data sheets available from the 
refrigerant and oil manufacturers. 

I.5.1.3 

Main Ecological Information Regarding the 

Types of Refrigerant Fluids Used 

 

Persistence, degradation and environmental impact 

Fluid 

Chemical formula 

GWP (over 100 

years) 

  

R32 

CH

2

F

550 

 

     R125 

C

2

HF

3400 

 

HFC R32 and R125 refrigerants are the single components which make 
up R410A when mixed at 50%. They belong to the hydrofluorocarbons 
group and are regulated by the Kyoto protocol (1997 and subsequent 
revisions) being gases that contribute to the greenhouse effect. The 
index that measures the behaviour of the refrigerant to the 
anthropogenic greenhouse effect is the GWP (Global Warming 
Potential). The standard GWP index for carbon dioxide (CO

2

) is 1. 

The value of GWP assigned to each refrigerant represents the 
equivalent amount in kg of CO

released over a period of 100 years, in 

order to have the same greenhouse effect of 1 kg refrigerant released 
over the same period of time. 
The R410A mixture does not contain elements that are harmful to the 
ozone, such as chlorine, therefore its ODP (Ozone Depletion Potential) 
is zero (ODP=0). 

 

 

  

Refrigerant 

R410A 

 

Components 

R32 / 

  

R125 

 

  

Composition 

50/50 

 

  

ODP 

 

     GWP (over 100 years) 

2000 

 

 

 

 

SAFEGUARD THE ENVIRONMENT! 
The hydrofluorocarbons contained in the unit 
cannot be released into the atmosphere as they are 
fluid that contributes to the greenhouse effect. 

R32 and R125 are derived from hydrocarbons that decompose 
relatively quickly into the lower atmosphere (troposphere). 
Decomposition products are highly dispersible and therefore have a 
very low concentration. They do not affect the photochemical smog, i.e. 
they are not classified among VOC volatile organic compounds, 
according to the UNECE agreement. 

 

Effects on effluent treatment 

Product waste released into the atmosphere does not cause long-term 
water contamination. 

 

Personal protection/exposure control 

Use protective clothing and gloves; protect eyes and face. 

 

Professional exposure limits: 

R410A 

HFC 32 

TWA 1000 ppm 

HFC 125 

TWA 1000 ppm 

 

Handling 

 

 

 

DANGER! 
Users and maintenance personnel must be 
adequately trained about the risks involved when 
handling potentially toxic substances. Failure to 
comply with the above-mentioned guidelines can 
cause personal injury or damage the unit. 

Avoid inhalation of high concentrations of vapour. The atmospheric 
concentration must be minimised and maintained at this minimum level, 
below the occupational exposure limits. The vapours are heavier than 
air, and therefore high concentrations may form close to the floor where 
overall ventilation is poor. In this case, ensure adequate ventilation. 
Avoid contact with naked flames and hot surfaces, which could lead to 
the formation of irritant and toxic decomposition by-products. Do not 
allow the liquid to come into contact with eyes or skin. 

 

Measures to be taken in case of an accidental leak 

Ensure adequate personal protection (using means of respiratory 
protection) during clean-up operations. If the conditions are sufficiently 
safe, isolate the source of leak. 
If the amount of the spill is limited, let the material evaporate, as long as 
adequate ventilation can be ensured. If the spill is considerable, 
ventilate the area adequately. 
Contain the spilt material with sand, soil, or other suitable absorbent 
material. 
Prevent the liquid from entering drains, sewers, basements or work pits, 
as they can create a stifling environment. 

I.5.1.4 

Main Toxicological Information on the Type 

of Refrigerant Used 

 

Inhalation 

A high atmospheric concentration can cause anaesthetic effects with 
possible loss of consciousness. Prolonged exposure may lead to an 
irregular heartbeat and cause sudden death. 
Higher concentrations can cause asphyxia due to the reduced oxygen 
content in the atmosphere. 

 

Contact with skin 

Splashes of nebulised liquid can produce frostbite. Unlikely to be 
hazardous if absorbed through the skin. Repeated or prolonged contact 
may remove the skin's natural oils, with consequent dryness, cracking 
and dermatitis. 

 

Contact with eyes 

Splashes of liquid can cause frostbite. 

 

Ingestion 

While highly improbable, may produce frostbite. 

I.5.1.5 

First Aid Measures 

 

Inhalation 

Move the person away from the source of exposure, keep him/her warm 
and let him/her rest. Administer oxygen if necessary. Attempt artificial 
respiration if breathing has stopped or shows signs of stopping. 
In the case of cardiac arrest carry out heart massage and seek 
immediate medical assistance. 

 

Contact with skin 

In case of contact with skin, wash immediately with lukewarm water. 
Thaw tissue using water. Remove contaminated clothing. Clothing may 
stick to the skin in case of frostbite. If irritation, swelling or blisters 
appear, seek medical assistance. 

 

Contact with eyes 

Rinse immediately using an eyewash or clean water, keeping eyelids 
open, for at least ten minutes. 
Seek medical assistance. 

 

Ingestion 

Do not induce vomiting. If the injured person is conscious, rinse his/her 
mouth with water and make him/her drink 200-300 ml of water. 
Seek immediate medical assistance. 

 

Further medical treatment 

Treat symptoms and carry out support therapy as indicated. Do not 
administer adrenaline or similar sympathomimetic drugs following 
exposure, due to the risk of cardiac arrhythmia. 

Summary of Contents for EQU-PF 2100

Page 1: ...eversibles monobloque de alto rendimientoconcondensaci nporaireyventiladorescentr fugos tipoPlug Fan conmotoresEC Air cooled chillers and heat pumps with radial fans Modelos 233 238 245 250 260 265 27...

Page 2: ...s to prevent hazard zones being reached by upper and lower limbs UNI EN 563 Safety of machinery Temperature of contact surfaces Ergonomic data to establish limit values for temperatures of hot surface...

Page 3: ...ce connection I 2 MACHINE IDENTIFICATION The identification data is found on the serial number plate which is located near the electrical panel The serial number plate must not be removed for any reas...

Page 4: ...r inlet temperature 47 C If the water inlet temperature to the condensers is lower than the permitted values it is recommended to use a three way modulating valve toguarantee EQU PF EQUH PF 270 2160 M...

Page 5: ...ned guidelines can cause personal injury or damage the unit Avoid inhalation of high concentrations of vapour The atmospheric concentration must be minimised and maintained at this minimum level below...

Page 6: ...al power supply Indicates the presence of live components Indicates the presence of moving parts belts fans Indicates the presence of hot surfaces refrigeration circuit compressor heads Indicates the...

Page 7: ...In the case of a single pump the unit is also complete with a delivery shut off valve In the case of a double pump the unit is complete with a non return valve and an intake valve for each pump Tank P...

Page 8: ...ed the unit remains powered DS Desuperheater it is not active during heat pump operation RC100 Heat recovery unit with 100 recovery the accessory is complete with a differential pressure switch on the...

Page 9: ...tional or local regulations in force at the time of installation Some internal parts of the unit can cause cuts Use suitable individual protective equipment If the unit is not secured on the antivibra...

Page 10: ...nit bear the following in mind non soundproofed reflecting walls near the unit can increase the total sound pressure level read near the appliance by 3 dB A for every surface install suitable antivibr...

Page 11: ...The screening must be connected to the earth screw on the panel on one side only The maximum permitted distance is 30 m CS Shifting Set point 4 20 mA signal SDS Double Set point selector control with...

Page 12: ...t be installed as well as system machine drain taps The rate of the water that flows through the heat exchanger must not drop below the value corresponding to a temperature differential of 8 C with bo...

Page 13: ...lect the TANK PUMP accessory complete with inertial storage tank and possibly install an additional tank However in process applications it is always advisable to use a storage tank or a greater syste...

Page 14: ...mation regarding performance of the units From 3 C to 8 C 30 From 0 C to 2 C 20 From 4 C to 1 C 10 Table H Minimum outdoor air temperature C 2 0 3 6 10 15 20 glycol in weight 10 15 20 25 30 35 40 Free...

Page 15: ...p PD RC100 DS consensus differential pressure switch FC Fan coil UT Upon use RI From the water mains ST Temperature probe SI Intermediate exchanger ST8 RC100 DS outlet temperature probe VSAC Water saf...

Page 16: ...he terminals of the power supply and of the contactors are tightened they may loosen during transport which could lead to malfunctions IMPORTANT The electrical connections must be made in compliance w...

Page 17: ...tion direction Do the pumps turn the right way Restore the water flow rate Is the water flow rate compliant with that indicated in the user manual Fill the circuits and or bleed the air Are the circui...

Page 18: ...el ON OFF key All ON OFF operations must be carried out EXCLUSIVELY using the ON OFF key on the control panel NO Does the earthing conform to current regulations Are the power circuit electric conduct...

Page 19: ...s anomaly If you take the pressure on the high pressure side to approx 8 bar are there gas leaks 3 grams year Stop the unit and verify the cause of the leak according to EN 378 2 Do alarms appear on t...

Page 20: ...probe from the socket taking care not to damage it in the process The probe must be carefully repositioned by placing some conductive paste in the socket inserting the probe and re sealing the extern...

Page 21: ...orrosion on the unit framework Any corrosion detected must be treated with protective paints in order to prevent possible damage II 9 1 2 Cleaning finned coils DANGER Pay attention to the edges of the...

Page 22: ...f necessary start up the utility pump 1 EQU PF EQUH PF 2 Auxiliary cock 3 Shut off gate valve 4 Wash pump 5 Filter 6 Acid tank II 9 2 Special Maintenance These are all those repairs or replacements th...

Page 23: ...nlet pipe If during the test phase the shut off valve closes completely without tripping the differential pressure switch switch off the unit immediately by pressing the ON OFF key on the control pane...

Page 24: ...unctions Insufficient cooling air to the coils check fans check clearances around unit and possible coil obstructions High ambient temperature check unit operation limits Refrigerant charge excessive...

Page 25: ...ystem size leaks and insulation Irregular operation of the expansion valve verify functions and replace if necessary Mechanical problems in the compressor repair compressor Insufficient refrigerant to...

Page 26: ...or y al personal encargado del mantenimiento sobre los riesgos debidos a la presencia de tensi n PELIGRO DE SUPERFICIES CORTANTES La indicaci n de PELIGRO DE SUPERFICIES CORTANTES se utiliza para info...

Page 27: ...ICACI N DE LA M QUINA Los datos de identificaci n se encuentran en la placa de caracter sticas aplicada cerca del cuadro el ctrico Esta placa no debe retirarse bajo ninguna circunstancia en caso de de...

Page 28: ...trada 47 C Si la temperatura del agua en la entrada de los condensadores es inferior a los valores admitidos se recomienda el uso de una v lvula de tres v as Modelos EQU PF EQUH PF 270 2160 En inviern...

Page 29: ...deben reducirse y mantenerse al nivel m nimo por debajo del l mite de exposici n profesional Los vapores son m s pesados que el aire por lo que es posible que se verifiquen concentraciones elevadas en...

Page 30: ...bajo tensi n Se ala la presencia de rganos en movimiento correas ventiladores Se ala la presencia de superficies calientes circuito frigor fico cabezas de los compresores Se ala la presencia de arist...

Page 31: ...n Si se cuenta con bomba doble la unidad dispone de una v lvula de no retorno y de una v lvula en la aspiraci n para cada bomba Tank Pump ASP1 Montaje con bomba y acumulador ASP2 Montaje con bomba co...

Page 32: ...se apaga la m quina siempre y cuando la unidad siga recibiendo energ a el ctrica DS Desobrecalentador no est activo en el funcionamiento como bomba de calor RC100 Recuperador de calor con recuperaci...

Page 33: ...rendimiento PELIGRO Es responsabilidad del personal respetar las normativas locales y nacionales vigentes al poner la m quina en funcionamiento Algunas partes internas de la unidad podr an causar cor...

Page 34: ...KRAS Racor antivibratorio de aspiraci n KRAM Racor antivibratorio de impulsi n Al instalar la unidad tenga en cuenta los siguientes puntos Las paredes reflectantes no aisladas ac sticamente cerca de...

Page 35: ...5 mm y el blindaje El blindaje se debe conectar a la barra de tierra presente en el cuadro en un solo lado La distancia m xima prevista es de 30 m CS Punto de consigna variable se al 4 20 mA SDS Sele...

Page 36: ...de la instalaci n y juntas el sticas de uni n al igual que grifos de desag e instalaci n m quina El caudal de agua a trav s del intercambiador no debe bajar a un valor inferior a un salto t rmico de...

Page 37: ...indicado o calculado es oportuno elegir el accesorio TANK PUMP con dep sito acumulador inercial y de ser posible instalar un dep sito adicional Aun as en las aplicaciones de proceso siempre es aconse...

Page 38: ...ener informaci n sobre las prestaciones de las unidades de 3 C a 8 C 30 de 0 C a 2 C 20 de 4 C a 1 C 10 Tabla H Temperatura m nima del aire exterior C 2 0 3 6 10 15 20 glicol en peso 10 15 20 25 30 35...

Page 39: ...de circulaci n PD Presostato diferencial permiso RC100 DS FC Fan coil UT En el uso RI De la red hidr ulica ST Sonda de temperatura SI Intercambiador intermedio ST8 Sonda temperatura de salida RC100 D...

Page 40: ...cuadro el ctrico y compruebe que los bornes de la alimentaci n y de los contactores est n apretados durante el transporte se pueden aflojar y esto puede causar problemas de funcionamiento IMPORTANTE...

Page 41: ...filtros de agua puestos antes del evaporador y del recuperador si est presente funcionan y est n correctamente instalados Restablezca o sustituya el componente Los interruptores de caudal instalados...

Page 42: ...EXCLUSIVAMENTE mediante el bot n ON OFF que se encuentra en el panel de mandos NO La conexi n de tierra cumple con las disposiciones de ley Los conductores el ctricos del circuito de potencia tienen l...

Page 43: ...a causa de la alarma V ase la tabla de las alarmas Hay alarmas en el display de la unidad Detenga la unidad y busque la causa de la fuga seg n EN 378 2 Si se pone la presi n en el lado de alta presi n...

Page 44: ...n colocadas dentro de un pozo en contacto con una pasta conductiva y bloqueadas en la parte externa con silicona Una se encuentra en la entrada del intercambiador y mide la temperatura del agua de ret...

Page 45: ...si n que puedan producirse deben tratarse con pinturas protectoras para evitar posibles da os II 9 1 2 Limpieza de las bater as de aletas PELIGRO Preste atenci n a los bordes afilados de la bater a Pa...

Page 46: ...iento la bomba de la aplicaci n 1 EQU PF EQUH PF 2 Grifo auxiliar 3 V lvula de corte de compuerta 4 Bomba de lavado 5 Filtro 6 Dep sito del cido II 9 2 Mantenimiento extraordinario Es el conjunto de i...

Page 47: ...ta por el usuario en el conducto de entrada de agua a la unidad Si durante la fase de prueba se llega a cerrar completamente la v lvula de corte sin la intervenci n del presostato diferencial apague i...

Page 48: ...amiento Aire de enfriamiento hacia las bater as insuficiente Revise que los ventiladores funcionen bien que se hayan dejado libres los espacios necesarios y que las bater as no presenten obstrucciones...

Page 49: ...ciones y aislamiento La v lvula de expansi n no funciona correctamente Compruebe su funcionamiento y de ser necesario sustit yala Problemas mec nicos en el compresor Controle el compresor Carga de ref...

Page 50: ...0 265 Absorbed power kW 13 8 13 2 17 9 22 4 25 0 26 9 Pump absorbed power P1 ASP1 P2 ASP2 kW 0 70 1 5 0 70 1 5 0 70 1 5 0 70 1 5 0 70 1 5 0 70 1 5 Electrical power supply V ph Hz 400 3 N 50 Auxiliary...

Page 51: ...pressor plate Electrical data 270 280 290 2100 2115 2130 2145 2160 Absorbed power kW 27 0 29 7 33 8 40 5 42 7 47 0 54 2 60 4 Pump absorbed power P1 ASP1 P2 ASP2 kW 1 1 2 2 1 1 2 2 1 5 3 0 1 5 3 0 1 5...

Page 52: ...3 17 1 21 3 23 4 26 2 Pump absorbed power P1 ASP1 P2 ASP2 kW 0 7 1 5 0 7 1 5 0 7 1 5 0 7 1 5 0 7 1 5 0 7 1 5 Electrical power supply V ph Hz 400 3 N 50 Auxiliary power supply V ph Hz 230 1 N 50 Contr...

Page 53: ...ode kW 27 2 29 6 35 5 40 5 42 3 47 1 54 6 61 1 Absorbed power in winter mode 26 9 28 1 32 7 38 8 41 6 45 7 53 7 59 4 Pump absorbed power P1 ASP1 P2 ASP2 kW 1 1 2 2 1 1 2 2 1 5 3 0 1 5 3 0 1 5 3 0 1 5...

Page 54: ...absorbida kW 13 8 13 2 17 9 22 4 25 0 26 9 Potencia absorbida bomba P1 ASP1 P2 ASP2 kW 0 70 1 5 0 70 1 5 0 70 1 5 0 70 1 5 0 70 1 5 0 70 1 5 Alimentaci n el ctrica de potencia V ph Hz 400 3 N 50 Alim...

Page 55: ...3x2 33 3x2 12 3x2 16 4x2 25 4x2 25 Caudal nominal ventiladores m h 26000 26000 27000 39000 39000 39000 52000 52000 Altura manom trica est tica til m xima de los Pa 250 250 250 250 250 250 250 250 Con...

Page 56: ...26 2 Potencia absorbida bomba P1 ASP1 P2 ASP2 kW 0 7 1 5 0 7 1 5 0 7 1 5 0 7 1 5 0 7 1 5 0 7 1 5 Alimentaci n el ctrica de potencia V ph Hz 400 3 N 50 Alimentaci n el ctrica auxiliar V ph Hz 230 1 N...

Page 57: ...5 5 40 5 42 3 47 1 54 6 61 1 Potencia absorbida en funcion invierno 26 9 28 1 32 7 38 8 41 6 45 7 53 7 59 4 Potencia absorbida bomba P1 ASP1 P2 ASP2 kW 1 1 2 2 1 1 2 2 1 5 3 0 1 5 3 0 1 5 3 0 1 5 3 0...

Page 58: ...2650 2650 2650 2650 2650 2650 d mm 724 724 724 724 724 724 e mm 1100 1100 1100 1100 1100 1100 f mm 2200 2200 2200 2200 2200 2200 g mm 322 322 322 322 322 322 h mm 257 257 257 257 257 257 i mm 176 176...

Page 59: ...3200 3200 3200 3200 4000 4000 4000 4000 g mm 300 300 300 300 300 300 300 300 h mm 205 205 205 205 205 205 205 205 i mm 256 256 256 256 256 256 256 256 l mm 530 530 530 530 400 400 400 400 m mm 1833 1...

Page 60: ...NOTE...

Page 61: ...S L Masia Torrents 2 Tel 34 938 934 912 Fax 34 938 939 615 08800 Vilanova i la Geltr Barcelona Spain www hitecsa com Reservado el derecho a efectuar modificaciones sin previo aviso Subject to modifica...

Reviews: