Hitecsa CLVBA-CLVA 401 Installation, Operation & Maintenance Manual Download Page 6

 
 


 
 

IOM_CLVBA-CLVA_401_208095_200801_EN

 

CLVBA-CLVA

 

EVAPORATION  UNITS AIR-AIR 

 

SAFETY PRECAUTIONS 

 

    

 

 
 
 
 
 
 
 
 
 
 

  DANGER

 

 

• In case of folding electrical panels, before folding them up in order to access to the interior of the machine, it is 
MANDATORY to disconnect the power supply hose from the electrical voltage, IT MUST ALWAYS BE FREE OF 
VOLTAGE for this operation.  
 
 

• Do not touch or adjust the safety elements inside of any unit of the system. Use only original spare parts in 

repairs and install them in the same position where old parts were placed. 
 
• The installation and maintenance of the air conditioning equipment could be dangerous because the system is 
under pressure, some of its elements have high temperatures and include electrical components.  
 
• Do not install the unit in the explosive atmosphere. 

 

 
 

 

ATTENTION! 

 
•  Only  qualified  and  trained  service  staff  (technical  service)  must  make  the  installation,  commissioning  and  carry  out 
maintenance works. Unqualified staff can only make basic tasks such as cleaning and replacement of filters, etc.  
 
• Prevent access to children so they cannot play with the appliances. 
 
•  In  every  visit,  all  precautions  must  be  taken  into  account:  those  recommended  in  the  installation,  operation  and 
maintenance instructions, as well as the ones indicated in labels of the unit. Do not forget to strictly follow any other safety 
precautions. . 
 
• DO NOT introduce objects into the air inlets or outlets that can be drawn into the fan, people, etc. 

 

• Use safety glasses, work gloves and any other safety accessory necessary. 
 
• For brazing operations use a quenching cloth and take precautions to have at close distance a fire extinguisher.  
 
• This product contains fluorinated greenhouse gases, its leakage can cause displacement of air and cause insufficient 
oxygen to breath. 
 

• All safety recommendations must be followed.  
 
 

 
 
 

 

 

Before starting installation, service or maintenance, turn off the main power switch in order 
to avoid electrical shock that may cause personal damages. 

 

WARNING! 

Summary of Contents for CLVBA-CLVA 401

Page 1: ...401_208095_200801_EN INDOOR UNITS FOR DUCT INSTALLATIONS AIR AIR CLVBA CLVA ECCEECHAECHA Cooling Only Heat Pump Model 401 Cooling Capacities 12 1 kW Heating Capacities 12 7 kW INSTALLATION OPERATION MAINTENANCE MANUAL ...

Page 2: ...oach is based on efficiency flexibility and on practical solutions This has been the hallmark of our product catalogue The versatility of our factory allows us to deliver solutions that can meet any requirement and we endeavour solving any problem that may arise in designing and implementing air conditioning installations From all of us at Hiplus Aire Acondicionado once again thank you very much ...

Page 3: ...N 8 RIGGING 8 STORAGE 8 INSTALLATION 9 INSTALLATION LOCATION 9 UNIT SETTLEMENT 9 SERVICE AREA MM 9 WEIGHT DISTRIBUTION 9 DIMENSIONS 10 DRAINAGE 11 AIR DUCTS 12 DESIGN OF THE REFRIGERANT PIPES 12 ELECTRICAL INSTALLATION 12 ELECTRICAL DATA 12 Electrical connections 13 OPERATION 14 BEFORE START UP 14 START UP 14 INDOOR FAN TRANSMISSION ADJUSTMENT 15 OPERATION LIMITS 16 MAINTENANCE 17 CONSERVATION AND...

Page 4: ...ontinuous improvement in design and performance to which we are committed to gives us the right to modify the specifications of our products without prior notice Electrical Supply Check that the electrical network features comply with the data shown in the data nameplate of the unit Local Safety Regulations Observe and analyse all the possible causes of accidents that may arise in the place or pla...

Page 5: ...ion or modification of the unit will automatically invalidate the warranty Packaging and Replacement of Equipment The material of the package plastic bags insulating materials nails etc is a potential source of danger Consequently it should be kept out of the reach of children and properly recycled according to the valid local safety regulations Do not mix this product with household waste at the ...

Page 6: ...ion commissioning and carry out maintenance works Unqualified staff can only make basic tasks such as cleaning and replacement of filters etc Prevent access to children so they cannot play with the appliances In every visit all precautions must be taken into account those recommended in the installation operation and maintenance instructions as well as the ones indicated in labels of the unit Do n...

Page 7: ... 10 SS Motor power kW 0 55 Voltage V 400 3 N REFRIGERANT Tiype R410A Global Warming Potential GWP 3 2088 Charge 4 1 Return temperature 27 C dry bulb and 19 C humid bulb evaporation temperature 7 C 2 Return temperature 20 C condensation temperature 40 C 3 GWP Global warming potential climatic of 1 kg of greenhouse gas relative to 1 kg of CO2 calculated in terms of 100 year warming potential 4 The c...

Page 8: ...milar to the one shown below Be sure to hoist the machine through the points indicated in the diagram Make sure that the unit is balanced stable and without any deformations when it is lifted STORAGE If the equipment is going to be stored before the installation please follow the instructions below in order to avoid damages corrosion or deterioration Move it carefully Do not place the machine in p...

Page 9: ...talled is able to support its weight in operation Fit shock absorbers throughout the installation to prevent the transmission of noise and vibration Check that the direction of the sound level is not going to disturb anyone UNIT SETTLEMENT Make sure that the unit is correctly levelled The bed frame should have the area and the strength to support the weight of the unit Be sure that after settlemen...

Page 10: ...AIR AIR INSTALLATION DIMENSIONS Model CLVBA CLVA 401 LEGEND 1 Electrical heater option 2 Supply plenum option 3 Heat water resistance option 4 Coil 5 Fan 6 Fan motor 401 model 7 Fan motor 501 model 8 Air filter 9 Power connexion inlet 10 Gas line 11 Liquid line 12 Drain ...

Page 11: ...on depending on the line length and general building configuration The drainage line should inclined a minimum 2 for proper water evacuation When drain line is exposed to temperatures below 0 degrees it is necessary to cover with thermal insulation or electrical heating wire to avoid water freezing and tube damages It is convenient to install the water drain trap with proper dimensions see diagram...

Page 12: ...e instructions stated in the condenstion unit ELECTRICAL INSTALLATION Unit power supply should be within 10 of volts indicated on the unit nameplate Damage caused by the start up of the unit in an incorrect voltage line is not covered by Hitecsa s warranty When making electrical connections always use the unit wiring diagram The line protection elements have to be placed by the installer according...

Page 13: ...APORATION UNITS AIR AIR INSTALLATION ELECTRICAL INSTALLATION Electrical connections For further information please refer to the user manual and to the electrical diagram Legend 1 Ground 2 Power supply 3 Magnetothermal circuit breaker D curve differential ...

Page 14: ...lied with any other voltage than that the indicated on the serial plate The power supply to the unit must be within 10 of the voltage indicated on the serial plate Check the correct rotation direction of the fans The installer must place line protection elements in accordance with current legislation Wiring of electrical connections must be protected by a tube or other cable conduits Make sure if ...

Page 15: ...et screws 4 Place the belt in the pulley cannel The closure of opening of the pulley could void the size of the prior belt In this case replace it for other belt of the same profile and with the appropriate length 5 Tighten the belt by using tensor screw or sliding the motor depending on the case Align fan and motor pulleys 1 Loose fan pulley set screws 2 Slide fan pulley along the shaft and align...

Page 16: ...nal value it means that the unit air flow is too low MODELS Nominal Pulley Correa Open kW A Fixed Variable 401 0 55 1 52 150 E20 1A 75 100 E19 1A A 40 1 OPERATION LIMITS AMBIENT AIR TEMPERATURE DRY TEMP HUMID TEMP COOLING CYCLE ºC ºC Standard conditions 27 19 Minimum conditions 21 15 Maximum conditions 32 21 AMBIENT AIR TEMPERATURE DRY TEMP DRY TEMP HEATING CYCLE ºC ºC Standard conditions 20 Minim...

Page 17: ...t be based on the working conditions to avoid the accumulation of dirt in propellers turbines motors and grids that could entail risks and shorten its life Be very careful not to unbalance the propeller or the turbine in cleaning operations Must observe the current safety legislations of each country in all maintenance and repairing works Motors and fans do not need any additional lubrication Tran...

Page 18: ...18 IOM_CLVBA CLVA_401_208095_200801_EN CLVBA CLVA EVAPORATION UNITS AIR AIR Subject to modifications without prior notice ...

Reviews: