07.16 207477 Rev.108 

 

ROOF TOP UNITS 

– AXIAL FAN  

 
 
 
 
 

RMXCA/RMXCBA

 

 

MODELS 4002.2 

– 4502.2 VRC 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

 

WEIGHT DISTRIBUTION (kg) 

KUBIC 

R1 

R2 

R3 

R4 

R5 

R6 

R7 

R8 

4002.2 

401 

383 

336 

200 

304 

312 

239 

205 

4502.2 

401 

393 

346 

309 

312 

312 

239 

205 

 

 

 

 

CENTRE OF GRAVITY(mm)

 

KUBIC 

4002.2 

2587 

1159 

896 

4502.2 

2592 

1164 

898 

LEGEND 

 

 Standard air supply 

  Optional air supply 

  Standard air return 

  Optional air return 

Condensate drainage  Ø3/4” 

  

Condensate drainage  Ø3/4” 

  Power supply 

  Electrical panel board 

Main power switch 

Air renewal damper 

Air extraction dumper 

Summary of Contents for 1402.2

Page 1: ...eration and Maintenance Manual Cooling Only Heat Pump RMXCA RMXCBA ROOF TOP UNITS AXIAL FAN Models 1402 2 1602 2 2002 2 2402 2 3002 2 3502 2 4002 2 4502 2 Cooling Capacities from 46 1 to 178 4 KW Heat...

Page 2: ...ears Our approach is based on efficiency adaptability usability and practical solutions This has been the hallmark of our product catalogue The versatility of our factory allows us to contribute solut...

Page 3: ...UBRICANT 16 STD TECHNICAL FEATURES 17 RCF MODULE TECHNICAL FEATURES 18 VRC MODULE TECHNICAL FEATURES 19 DIMENSIONS 20 MODELS 1402 2 1602 2 STD 20 MODELS 2002 2 3002 2 STD 21 MODELS 3502 2 STD 22 MODEL...

Page 4: ...of children Recycle packaging materials in accordance with local law Units must be used only for the purpose for which they were designed The manufacturer is not liable in the case of applications ot...

Page 5: ...y accessory recommended for any particular task For brazing operations use a quenching cloth and keep a fire extinguisher at a close distance When repairing the unit use only original spare parts and...

Page 6: ...y Raise and set down the equipment carefully During the transport never tip or roll the unit more than 15 degrees To lift the unit a crane can be used Suggestions for the transport company are found b...

Page 7: ...se a location free of dust and foreign matter which can clog or damage condenser coil Consult and respect all regulations concerning installation of air conditioning systems UNIT SETTLEMENT Kg Ensure...

Page 8: ...8 07 16 207477 Rev 108 ROOF TOP UNITS AXIAL FAN RMXCA RMXCBA MODEL 3502 2 STD MODELS 4002 2 4502 2 STD...

Page 9: ...9 07 16 207477 Rev 108 ROOF TOP UNITS AXIAL FAN RMXCA RMXCBA MODELS 1402 2 3002 2 RCF MODEL 3502 2 RCF...

Page 10: ...10 07 16 207477 Rev 108 ROOF TOP UNITS AXIAL FAN RMXCA RMXCBA MODELS 4002 2 4502 2 RCF MODELS 1402 2 3002 2 VRC...

Page 11: ...11 07 16 207477 Rev 108 ROOF TOP UNITS AXIAL FAN RMXCA RMXCBA MODEL 3502 2 VRC MODELS 4002 2 4502 2 VRC...

Page 12: ...tions 1 Power Supply 400V 3N 50Hz 2 Disconnect Switch 3 Control POWER SUPPLY 230 v AC 3 2 BELDEN TYPE BRAIDDING AND SHIELDED 1 L N T Ensure that all electrical connections are correct Ensure that all...

Page 13: ...titude of 1500 m For other conditions please consult us For lower temperatures it is necessary to use the condensation control supplied as optional The electrical power supply to the unit should agree...

Page 14: ...ctions The indoor drain of condensate water has an MPT 3 4 pipe connection The outdoor recovery drain of condensate water has MPT 3 4 pipe connection Condensate evacuation line diameter should be equa...

Page 15: ...ption reaches its nominal value If consumption is below the nominal value then the airflow in the unit is too low To change fan speed 1 In order to remove belt move motor along its track 2 Loosen pull...

Page 16: ...to atmosphere more than 15 minutes Compared to the mineral oil used with R22 compressors polyoilester lubricants absorb more than 100 times more the moisture Mineral oils or alkylbenzene type synthet...

Page 17: ...CIRCUIT Nominal air flow m 3 h 9000 10200 11500 14000 15500 21000 23000 25000 Available static pressure Pa 100 125 150 Quantity Size 15 15 2 x 15 11 2 x 18 18 Power kW 1 5 2 2 2 2 4 4 4 5 5 5 5 Speed...

Page 18: ...0 21000 23000 25000 Static pressure available Pa 100 100 125 125 125 150 150 150 Quantity Size 15 15 2 x 15 11 2 x 18 18 Power kW 1 5 2 2 2 2 4 4 5 5 5 5 7 5 Speed rpm 649 726 712 802 860 716 756 798...

Page 19: ...00 Available static pressure Pa 100 100 125 125 125 150 150 150 Quantity Size 15 15 2 x 15 11 2 x 18 18 Power kW 1 5 2 2 2 2 4 5 5 4 5 5 5 5 Speed rpm 616 677 712 802 860 642 673 860 Condensates drain...

Page 20: ...198 182 119 1602 2 199 138 119 204 196 119 CENTRE OF GRAVITY mm KUBIC X Y Z 1402 2 1267 1147 604 1602 2 1269 1148 604 LEGEND Standard air supply Optional air supply Standard air return Optional air re...

Page 21: ...ard Main power switch Electricity supply Condensate drainage 3 4 Anchorage silent block M12 Mouth profile 25 mm Equipment chassis width 130mm WEIGHT DISTRIBUTION kg KUBIC R1 R2 R3 R4 R5 R6 2002 2 203...

Page 22: ...air return Optional air return Condensates drainage 3 4 Power supply Electrical panel board Main power switch Anchorage silent block M12 Mouth profile 25 mm Equipment chassis width 130mm WEIGHT DISTR...

Page 23: ...4502 2 401 337 210 309 254 210 CENTRE OF GRAVITY mm KUBIC X Y Z 4002 2 1718 1153 952 4502 2 1709 1150 947 LEGEND Standard air supply Optional air supply Standard air return Optional air return Condens...

Page 24: ...urn Optional air return Electrical panel board Main power switch Power supply Condensate drainage 3 4 Condensate drainage 3 4 Air renewal damper WEIGHT DISTRIBUTION kg KUBIC R1 R2 R3 R4 R5 R6 R7 R8 14...

Page 25: ...402 2 210 153 147 175 213 213 151 183 3002 2 212 158 156 193 215 238 151 208 CENTRE OF GRAVITY mm KUBIC X Y Z 2002 2 1941 1122 578 2402 2 1941 1124 578 3002 2 1912 1130 577 LEGEND Standard air supply...

Page 26: ...ir supply Standard air return Optional air return Electrical panel board Main power switch Power supply Condensate drainage 3 4 Condensate drainage 3 4 Air renewal damper WEIGHT DISTRIBUTION kg KUBIC...

Page 27: ...urn Optional air return Condensate drainage 3 4 Condensate drainage 3 4 Power supply Electrical panel board Main power switch Air renewal damper WEIGHT DISTRIBUTION kg KUBIC R1 R2 R3 R4 R5 R6 R7 R8 40...

Page 28: ...3 142 128 115 198 182 139 136 1602 2 199 145 130 115 205 187 143 141 CENTRE OF GRAVITY mm KUBIC X Y Z 1402 2 1898 1149 574 1602 2 1894 1147 574 LEGEND Standard air supply Optional air supply Standard...

Page 29: ...2402 2 210 153 137 130 213 213 169 151 3002 2 212 158 137 130 215 238 184 168 CENTRE OF GRAVITY mm KUBIC X Y Z 2002 2 1889 1168 584 2402 2 1882 1171 584 3002 2 1868 1177 583 LEGEND Standard air supply...

Page 30: ...7 R8 3502 2 387 331 304 200 289 283 239 205 CENTRE OF GRAVITY mm KUBIC X Y Z 3502 2 2624 1145 867 LEGEND Standard air supply Optional air supply Standard air return Optional air return Condensate drai...

Page 31: ...0 304 312 239 205 4502 2 401 393 346 309 312 312 239 205 CENTRE OF GRAVITY mm KUBIC X Y Z 4002 2 2587 1159 896 4502 2 2592 1164 898 LEGEND Standard air supply Optional air supply Standard air return O...

Page 32: ...r correct installation of the accessory UPPER RAIN HOOD LOWER RAIN HOOD POSITIONING OF THE RAIN HOODS The correct installation of the rain hood accessory is very important to guarantee the proper perf...

Page 33: ...ction 2 Place the inclined rain hood at the lower window Air renewal DIMESIONS 1402 3002 In case the rain hoods were placed upside down the inclined wall would push the outlet air downwards and this c...

Page 34: ...34 07 16 207477 Rev 108 ROOF TOP UNITS AXIAL FAN RMXCA RMXCBA DIMENSIONS 3502 4502...

Page 35: ...ear during operation it s necessary to carry out a leak test Leak detectors usually employed with CFC and HCFC cannot be used with R410A due to chlorine in its composition A leak detector for R134a ma...

Page 36: ...adings and record them on the maintenance form Electrical circuit Make sure that all electrical cables are properly tightened Be sure that there are no faulty terminals contactors etc Take the measure...

Page 37: ...nger of suffocation due to the reduction of oxygen content in the atmosphere Remove patient to fresh air and keep warm and at rest Administer oxygen if necessary Apply artificial respiration if the pa...

Page 38: ...Wear overalls impervious gloves and eye face protection How to act in case of spill accidental release Make sure to wear protective clothing and breathing apparatus If not dangerous isolate the sourc...

Page 39: ...Rights reserved subject to change without notice HIPLUS AIRE ACONDICIONADO S L Masia Torrents 2 Tel 34 93 893 49 12 Fax 34 93 893 96 15 08800 Vilanova i la Geltr Barcelona Spain www hitecsa com...