Hitec Luxembourg S.A. |
5, Rue de l’Église, L-1458 Luxembourg
www.hitec.lu | [email protected] | Tel.: (+352) 49 84 78 - 1 | Fax. (+352) 401303
File Name: HTCA_003-DADS-UserManual.docx
Document Type: End User Manual | Version date: 01/05/2010 | Last Printed: 15/02/2011
Page 69/81
Local Mode
When some maintenance action must be done on
the equipment, there is the possibility to enter on a
Local Mode to read some values and run the motor
without need of the computer.
To enter in this Local Mode, you need to switch
OFF and ON the equipment.
When the Terminal shows the software version and
a star at the right side, push the
button a few
seconds.
Then the display will return as follow:
Description of Terminal display on Local Mode, from left till right:
Motor relay activation;
Motor status (run - 1, stop - 0, overload - 2);
ADC Torque Value;
ADC Temperature Value;
ADC Motor Speed;
??????????
Run Motor on Local Mode
On the local mode you can run the motor in case of
need for general maintenance or any other action.
Push the
button to activate the system, the first
value on left will change to
1
.
Push the Start button on the “DABS Front door”, the
motor starts and the second value on the left will
change to
1
.
If the torque gets overload, this value will change to
2
, the first to
1
and the motor stops. To
reset, push the
button and the display will return
0
for the two values.