Hitec Luxembourg S.A. |
5, Rue de l’Église, L-1458 Luxembourg
www.hitec.lu | [email protected] | Tel.: (+352) 49 84 78 - 1 | Fax. (+352) 401303
File Name: HTCA_003-DADS-UserManual.docx
Document Type: End User Manual | Version date: 01/05/2010 | Last Printed: 15/02/2011
Page 68/81
Changing Drive
If you work with more than one chamber or you need to replace the drive, you can do it as
follow.
1. Loosen the 4 screws below the bowl and pull chamber and drive in your direction to
take it out from place;
2. If not in place, you will need maybe to move the clutch half from one drive to the other
one.
3. Set the mixing chamber in place and put the 4 screws to
hold it in place but do not tighten completely at this
moment.
4. See if there is a gap of 2mm at least between the two
clutches. If not, remove the chamber and readjust its
clutch half. Repeat till it is fine.
5. With the drive in place with the screws not tighten, start
the motor a few seconds. This is to align the chamber
with the motor. Stop and start the motor two, three times.
6. Then you can tighten the 4 screws in
X
form (see red arrows on first figure).