PMML0600 rev.0 - 06/2022
6
SETTING OF DIP SWIT
CHES AND R
SW SWIT
CHES
ELEC
TRICAL AND C
ONTROL SETTINGS
NOTE
•
This operation is reset once the compressor is in Thermo-ON mode.
•
During the test run operation the units will operate continuously during 2 hours without Thermo-
OFF and the 3-minute guard for compressor protection will be effective.
•
Test run will start within 20 seconds after setting DSW1 pin 1 to ON position.
6.2.1.2 DSW2
◆
Optional Function setting
RASM-(2/3)VRE: PCB1
RASM-(4-6)VR(W)1E: PCB2
RASM-(4-7)R(W)1E: PCB1
DSW2
RASM-(2/3)VRE
RASM-(4-7)(V)R(W)1E
Factory setting
6
5
4
3
2
1
6
5
4
3
2
1
Function selection setting mode
6
5
4
3
2
1
6
5
4
3
2
1
External input, output setting mode
6
5
4
3
2
1
6
5
4
3
2
1
◆
Not used
RASM-(4-7)R(W)1E: PCB2
DSW2
RASM-(4-7)R(W)1E
Factory setting
4
3
2
1