--- 5 ---
Product
Unit
Overall length
mm
Weight
g
Hitachi
WH 9DM2
48.6 (1-29/32")
160 (0.35 lbs.)
Hitachi
WH 9DM
57.6 (2-17/64")
214 (0.47 lbs.)
C
57.0 (2-15/64")
175 (0.39 lbs.)
WH 9DM2
WH 9DM
C
Product
Unit
mm
Center height
mm
Height
mm
Overall length
Measured value kg
kg
Catalog value
Weight
Hitachi
WH 9DM2
147 (5-25/32")
26.5 (1-3/64")
223 (8-25/32")
1.2 (2.6 lbs)
1.29 (2.8 lbs)
Hitachi
WH 9DM
167 (6-37/64")
26 (1-1/64")
221 (8-45/64")
1.4 (3 lbs)
1.46 (3.2 lbs)
164 (6-29/64")
25 (1-63/64")
236 (9-5/16")
1.1 (2.4 lbs)
1.13 (2.5 lbs)
C
Model
WH 9DM
C
Number of trigger switch depressing
0.68 N
•
m {6.9 kgf
•
cm, 6.0 in-lbs.}
2.0 times
(Reference) WH 12DM2
WH 9DM2
8.6 times
5.0 times
7.4 times
0.95 N
•
m {9.7 kgf
•
cm, 8.4 in-lbs.}
0.71 N
•
m {7.2 kgf
•
cm, 6.2 in-lbs.}
1.26 N
•
m {12.8 kgf
•
cm, 11.1 in-lbs.}
Table 1
3
(2) 30% lower striking start torque
The Model WH 9DM2 has lower striking start torque 0.68 Nm {6.9 kgf
•
cm, 6.0 in-lbs} than the current Model
WH 9DM (0.95 Nm {9.7 kgf
•
cm, 8.4 in-lbs}) to minimize damage to the screws. Thanks to the lower striking
start torque, the Model WH 9DM2 is optimum for light-duty works such as tightening sash screws, plastic
screws and Teks screws because it gives less damage to the small screws and the workpieces.
Table 1 shows a comparison of number of trigger switch operations when tightening a tapping screw D4 x 25
in a workpiece of nylon resin (prepared hole diameter 3.5 mm) until each driver idles. The Model WH 9DM2
has the highest resistance to idling because the number of adjustments is most frequent. (The switch is
turned off immediately after striking is started. The higher the striking start torque, the longer tightening time is
required and the driver is apt to idle.)
Compact and lightweight hammer assembly
The hammer assembly is newly designed according to the maximum tightening torque 80 N
•
m.
Comparison of the hammer assembly
4
Appearance and dimensions
Cordless impact driver: Model WH 9DM2
Striking start torque
* The data above are intended for reference purpose only because actual number of trigger
switch depressing may vary depending on tightening conditions.