Capacity of all pools
Capacity required for additional SM
*You must expand SM when pool capacity is more than 1.1 PB.
For VSP Gx00 models and VSP Fx00 models, additional shared memory is
required when the total capacity of all pools exceeds the following values:
• VSP G200: 0.12 PB
• VSP G400, G600, G800, VSP F400, F600, F800: 0.2 PB
For more information about capacity available for additional shared memory
for VSP Gx00 models and VSP Fx00 models, see the hardware guide for your
storage system.
You can reduce or remove shared memory if the pools for Dynamic
Provisioning, Dynamic Tiering, active flash, and Thin Image have been
deleted. When creating cascaded pairs or clone pairs, you must add shared
memory:
• For VSP G1000, G1500, and VSP F1500: 64KLDEV Extension
• For VSP Gx00 models and VSP Fx00 models: Extension1
For more information about how to expand, reduce, or remove shared
memory, contact customer support.
Related concepts
•
Switching off the power supply
on page 193
Related tasks
•
on page 187
Thin Image volume requirements
Thin Image requires three types of volumes.
The following types of volumes are required:
• P-VOLs
• S-VOLs
• Pool-VOLs
The following table lists the requirements for Thin Image P-VOLs.
Please note that "Pool VOLs" refers to Thin Image pool volumes. For
information about DP pool volumes, see the
Provisioning Guide
for your
storage system.
Item
Requirement
Volume type
Logical volumes (LDEVs).
You cannot specify the following volumes as HTI P-VOLs:
70
Thin Image system and planning requirements
Hitachi Thin Image User Guide for Hitachi Virtual Storage Platform G Series and F Series