Number
Item
Description
4
Backup module
N/A
5
BACKUP
LED
Green: Power restoration in
progress following power
outage.
Fast blink green: Restoring.
Slow blink green: Restoring, or
sequential shutdown in
progress.
6
Cache flash memory
N/A
7
ALM
LED (for cache flash
memory)
Red: Cache flash memory can
be removed.
8
CTL ALM
LED
Red: Controller can be
removed.
Blink red: Failure with the
power supply unit of the
controller.
Amber: LAN reset switch was
pressed.
9
LAN-RST switch
Use only when instructed by
customer support.
10
STATUS
LED (for BKMF)
Green: Charging of the battery
in the backup module is
complete.
Red: Backup module can be
removed.
Blink red one time: Main
battery failure.
Blink red two times: Backup
battery failure.
Blink red three times: Both
batteries failed or preventive
maintenance replacement of
batteries can run.
Off: Battery is not mounted,
battery-mounting failure
occurred, or firmware is being
upgraded. Off is normal status
for configurations without
batteries (for example,
BKMF-10 and BKMF-20).
CBLH rear panel
The following table describes the definitions of the CBLH controller rear panel
LEDs.
22
Virtual Storage Platform F800 controller
Hitachi Virtual Storage Platform F800 Hardware Reference Guide
Summary of Contents for Virtual Storage Platform F800
Page 1: ...Hitachi Virtual Storage Platform F800 Hardware Reference Guide MK 94HM8046 07 July 2017 ...
Page 6: ...6 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...
Page 38: ...38 Storage system drive trays Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...
Page 44: ...44 Host port expansion chassis Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...
Page 85: ...Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...